My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2007 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
2500
>
2300 - Underground Storage Tank Program
>
PR0232507
>
BILLING 2007 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2023 2:23:14 PM
Creation date
11/6/2018 11:33:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2007 - 2015
RECORD_ID
PR0232507
PE
2361
FACILITY_ID
FA0003846
FACILITY_NAME
Verizon Business: LDIKCA
STREET_NUMBER
2500
Direction
W
STREET_NAME
TURNER
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
029-030-39
CURRENT_STATUS
01
SITE_LOCATION
2500 W Turner Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\TURNER\2500\PR0232507\BILLING 2007 - 2015 .PDF
QuestysFileName
BILLING 2007 - 2015
QuestysRecordDate
9/8/2016 6:06:18 PM
QuestysRecordID
3186027
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-'NIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK � <br /> MONITORING PLAN- a e 1 ort <br /> TYPE OF ACTION ❑ 1.NEW PLAN ® 2.CHANGE OF INFORMATION 49x-1 <br /> PLAN TYPE i9 1.MONITORING IS IDENTICAL FOR ALL USTS AT THIS FACILITY. <br /> Check one item only) ❑ 2 THIS PLAN COVIAS ONLY THE FOLLOWING UST SYSTEM <br /> .,.,..,sn..� .r ..s• - ,, Ii FEICIL'I'fi�X�1�!1I'�L?�M�tA � �,.��.I°�t��+ ..,*r <br /> FACILITY ID#(Agency Um Only) <br /> BUSINESS NAME(Same as FACILITY NAME)MCI, dba, Verizon Business 3. <br /> BUSINESS SITE ADDRESS 2500 W.Tomer Road 103' CITY Lodi 104. <br /> xf..fc r s <br /> 25 "L,'Si4h^. .,._,A <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,serta M probes,line leak detectors,etc.)must be perforated at the frequency <br /> specified by the equipment manufacturers'instruaious,or annually,whichever is more frequent,and that such work must be performed by qualified personnel. <br /> 23 CCR 263Z 2634,2638,2641 _ <br /> MONITORING EQUIPMENT IS SERVICED ..rad® 1.ANNUALLY M El 99.OTHER(Specify): 4s 3b <br /> �a > M <br /> S <br /> "' <br /> v - <br /> ❑1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN. R&2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED. (23 CCR§2632, <br /> 2 _ <br /> r>>•:' ;z��iueA15K,��015 �����>�PERF�,Qb�7SINCs�T���,1.C� .:: G,A.�ETHOD($)„� <br /> 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT 490-5 <br /> VAULT(S)WITH AUDIBLE AND VISUAL ALARMS. (23 CCR§2632,2634) <br /> SECONDARY CONTAINMENT IS: Z a DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑d.UNDER VACUUM 49x6 <br /> PANEL MANUFACTURER: Pneumercator 490.7' MODEL#: TMS2000 4994 <br /> LEAK SENSOR MANUFACTURER: Pneumercator 49P9. MODEL#S: LS610 490-10 <br /> 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANIUS).(23 CCR§2643) 490-11 <br /> PANEL MANUFACTURER: 49x11 MODEL.#: 49 13 <br /> IN-TANK PROBE MANUFACTURER: 490-14. MODEL#(S: 490.15 <br /> LEAK TEST FREQUENCY: ❑ a CON'T'INUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 490-16 <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 4W17 <br /> PROGRAMMED TESTS: ❑ a 0.1g p•h. ❑ b.0.2 g.p.h. ❑ c.OTHER(Specify): 49 19 <br /> ❑ 3.MONTHLY STATbTICAL INVENTORY RECONCILIATION(23 CCR§2646.1): 49020 <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MIG)(23 CCR§2645). TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS 49021 <br /> 4902: <br /> 5.TANK INTEGRITY TESTING(23 CCR.§2643.1): 490'21 <br /> TEST FREQUENCY: ❑ a ANNUALLY ❑ b.BIENNIALLY ® c.OTHER(Specify): 49x15 <br /> [199.OTHER (Specify): 44" <br /> `"�o:``i�dii����"�.����gEnusn�r' �ol�i;��►�`?���9t?��Tt���ka .ba��ePp�r), �` <br /> ®1.CONTINUOUS.MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND 49x28 <br /> VISUAL ALARMS. (23 CCR§2636) <br /> SECONDARY CONTAINMENT IS:®a.DRY ❑b.LIQUIDFILLED ❑c.PRESSURIZED ❑d.UNDER VACUUM 490.29 <br /> PANEL MANUFACTURER:Pneumercator 490-10 MODEL! <br /> : TMS2000 090.31 <br /> LEAK SENSOR MANUFACTURER: Pneumercator 990'3 MODEL#(S): LS600 49x33 <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(Le.,TURBINE)SHUTDOWN. ❑a YES ❑b.NO °90'J0 <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a YES ❑b.NO 49o-3s <br /> 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED CCR 263 490.36 <br /> MLLD MANUFA $: 990.37 MODEL#(S): 4W19 <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p h.LEAK TESTS (23 CCR§2636) 490x9 <br /> ELLD MANUFACTURE S ' MODEL#(S): . 490x1 <br /> PROGRAMMED IN LINE LEAK TEST: ❑ L MINIMUM MONTHLY 0.2 g.p.h. ❑ 2.MINIMUM ANNUAL:0.1 g.pJL 490.42 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 990.4] <br /> ELLD FAILUREIDISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a YES ❑b.NO 490.°4 <br /> ® 4.PIPE INTEGRITY TISTING 49045 <br /> TEST:r <br /> UENCY S &ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify) 49 649M7 <br /> ❑ S.VISUAL PIPE MONITORING. 49049 <br /> FREQUENCY ❑ a DAILY ❑ b.WEEKLY ❑c.MIN.MONTHLY&EACH TudE SYSTEM OPERATED- 490.49 <br /> •A ed for=nhoring or=b Wm, fiat pipmx onl HSC 252115 3 <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA(23 CCR§2636(a)(3)]. 49x50 <br /> 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.71S CONNECTED TO THE TANK SYSTEM <br /> K 51 <br /> ❑ 99.OTHER(Specify) 49as� <br /> UPCF UST-D(122007)114 <br />
The URL can be used to link to this page
Your browser does not support the video tag.