My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_PLAN 2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
12TH
>
10
>
2300 - Underground Storage Tank Program
>
PR0231873
>
REMOVAL_PLAN 2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 1:36:46 PM
Creation date
11/6/2018 11:40:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
PLAN 2002
RECORD_ID
PR0231873
PE
2361
FACILITY_ID
FA0003956
FACILITY_NAME
PACIFIC BELL - UE058 (TRACY)
STREET_NUMBER
10
Direction
E
STREET_NAME
12TH
STREET_TYPE
St
City
TRACY
Zip
95376
APN
23336922
CURRENT_STATUS
01
SITE_LOCATION
10 E 12TH St
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\T\TWELFTH\10\PR0231873\REMOVAL PLAN 2002.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MOUNTING INSTRUCTIONS: <br /> LAYOUT AND DRILL TWO (2) <br /> E <br /> HOLES IN BACK OF. BOX B p WESTERN FIBERGLASS MATERIAL LIST <br /> NOTE: WHERE SHOWN. _ �� C QA 1' AND 1 1/2' PRIMARY FLEX PIPE - <br /> DRILL WALL AND ATTACH TRANSITION PIPING TO 1' & 1 1/2'ASTM --HOLE SAW THROUGH GENERATOR PI 3500, PI 4500 <br /> CONTACT EMCC UNI-STRUT AS REQUIRED BY SAN 40 BLACK STEEL INSIDE 3/1 s" ENCLOSURE FOR PIPING. B <br /> FOR LABELS WALL CONSTRUCTION TYPE. I ENCLOSURE <br /> E AND CONNECT TO FUEL PUMP WITH O <br /> HOSEMASTER FIRE SHIELD FLEX CONNECTORS PROVIDE 6' DN ASTM A53 4' SECONDARY FLEX PIPE - PI 4537 <br /> (1 -800-757-6575) ATTACH BOX TO UNISTRUT I - - SCH 40 PIPE, SHOP <br /> i - FORMED TO 36'R 90 DEG. © x x 1 1/2* DUPLEX REDUCING <br /> WITH HARDWARE INDICATED FOS - BEND BOOT W1 TEST PORT <br /> HEREIN. I ��' END OF WELDED PIPE FOR - OTHER E9UII'MENT <br /> i <br /> -36" RADIUS Op 8' DIA. ASTM A53 NIPPLE 8' LENGTH <br /> i COAT EXTERIORWIM OF <br /> 00 \ STEEL PIWITH O TRACER WIRE WITH BOLT TERMINATION <br /> � SCOTCH KOTE 206N. <br /> PETROLEUM FUEL STORAGE TANK /i FLEX CONNECTOR <br /> i HOSE MASTER "FIRE GENERATOR <br /> (PST) MONITORING RECORDS � O r O\ `�,\ ;" GENERATOR ONNECT O 5b1 ENCLOSURE <br /> iMOUNT VEEDER- 1 \ <br /> i GENERATOR WITH ROOT SENSOR AT 1 <br /> DRILL TWO (2) 3/8' j' RETURN PUMP FLOOR LEVEL 1 1 11 3/76' <br /> DIA, HOLES IN THE 6" DP. x 10' HI. x 13 1/2' BY OTHERS <br /> BACK OF THE BOX LONG FILE BOX !794360-208 11 1 <br /> GRADE TO DRAIN <br /> % <br /> PIPE <br /> PROVICOLLAR DE CRETE ° •� i s 1 4. <br /> PETROLEUM FUEL STORAGE TANK 2 �4 - <br /> (PST) MONITORING RECORDS _.. _ ... `. ® II �c <br /> i I 11 <br /> 24-1 <br /> QUESTIONS — — — — — — — RI <br /> CONTACT:f7ACC 1-800-757-6575 <br /> 1 1 11 <br /> HARDWARE <br /> AS WAIT 1 \\\ <br /> HN2DWARE AS REQUIRED 1 5/8„ <br /> SWEEP PRODUCT \\ \\ <br /> BY WP11 CONSTRUCTION PIPING UP TO 6` \ \ <br /> TYPE -- (4 REQUIRED) SLEEVE --. <br /> HARDWARE LIST: \ <br /> UNISTRUT JP2000HS x 11 1/4" LG., FACTORY <br /> PRE-DRILLED -- (2 REQUIRED) NEW <br /> \� <br /> DECAL LOCATIONS DETAIL MOUNTING DETAIL UNISTRUT jPl007 NUT WITH SPRING -- (2 REQUIRED) UDERGROU'1D A <br /> (DECALS FURNISHED BY EMC) (MOUNT ADJACENT TO TLS 350) HEX HEAD CAP SCREW, 5/18'-18 N.C. x 1" LG. FUEL PIPING <br /> WITH FIAT WASHER -- (2 REQUIRED) _--_-_- <br /> 4 TANK MONITORING RECORDS BOX No SCALE1 TRANSITION DETAIL NO SCALE <br /> ALL VENT RISER SUPPORTS TJRMINATE VENT LINE WITH IMPACT c_AcE <br /> TO BE INSTATED ABOVE ,;�JAII]ONS TANK BREATHER iT6000U. CAP <br /> DIELECTRIC UNION IIT BE PLACED 18' MIN, ABOVE ADJACENT <br /> ,YLVL-RDOF, ENCLOSURE OR PER LOCAL <br /> EXISTING WALL ROOF UNE OF STRUCTURE, FRE CODE (IMPACT ABSORBENT <br /> TOP 0* WALL OR /]I.;CHFIOLOGIES, INC. (6051466-4709). <br /> 12'-0' ABOVE GRADE <br /> SECURE PIPE & CONDUIT TO <br /> BUILDING, AITACHMENfssr <br /> 2' SCOTCH COAT SCH. 40 -�- 2 ti <br /> DETERMINED BY STRUCTURE q� <br /> BLACK RISER SURFACE <br /> PIPE WENT �/ SURFACE <br /> f w C 5721 m' <br /> Sa* exo, 12310Js g, A; <br /> A BUILDING <br /> Fa OR WALL \ <br /> O N \ <br /> PHIL-TYLE CONTAINMENT SUMP SEE <br /> S OVERFILL <br /> • • OVERFILL ALARM SHEET 13 FOR DETAILS. 2"-150IRON COUPLING \ REVISIONS / AUTHORIZATIONS <br /> I OVERFILL ALARM <br /> N 1-#12 & 1-#1 I 3/4" D./W 2-#12 & <br /> GRD.3/4' a 1—#12 GRD. WELD 100X N0. REVISIONS / AUTHORIZATIONS DATE BY <br /> C./W 2 #14 OVERFILL ALARM 5 GALLON SPILL CONTAINER <br /> ACKNOWLEDGMENT PHILTRE #85100-F WITH 1/2' 1501 <br /> L -Box / BULL PLUG \ ION COUPLING ISSUED FOR BID ++N/OT MED <br /> Z SWITCH PP7005TB TIRASH LTASKET. ISSUED FOR CONSTRUCTION a/7/roz Mm <br /> if 16 GAUGE STEEL �+ 1 �° <br /> u BOARD (PAINT TO I ATTACH 16 GAUGE <br /> MATCH (AST) METAL BOARD TO 3'-150/ MALLEABLE \ \7/2` PLUG <br /> n • WALL WITH FASTENERS -4' CAM CONNECTOR WITH CAP. IRON COUPLING ` WELD t00% <br /> a PER EQUIPMENT BOARD MORRISON_ BROS. 305GU CAP <br /> SIDE ELEVATION "A" . —';.7/,3w <br /> VWTCH ROOT t3" HEREONGRAN VALVE WffH SPILL FILTER . PROPRIETARY SBC INFORMATION <br /> OVERFILL ALARM I , NOT FOR GENERAL USE OR DISCLOSURE OUTSIDE OF SBC <br /> ACKNOWLEDGEMENTENVIRONMENTAL MANAGEMENT UNDER EXEMPTIONS SET FORTH IN <br /> S'MTCH I ITHE CALIFORNIA PUBLIC RECORDS ACT, THIS INFORMATION MAY <br /> iO FOOTINJE GRADE ONLY BE USED BY AUTHORIZED PERSONNEL. OF THE LOCAL <br /> GOVERNMENT AGENCY IN CONNECTION WITH APPLICATION FOR <br /> PER ITS AND AUTHORIZATIONS FOR BUILDINGS, CONSTRUCTION, <br /> p 3/4" C./W 2-#12 To AND OR ZONING CHANGES. <br /> E V.R. 350 1.0. BOARD & 3' MN <br /> BE <br /> DRAWINGS PREPARED FOR <br /> 2-#12 & 1-#12 GRD. 3 S11iEl. FILL TUBE CLAY AND BAILEY F35. FIBERG <br /> ' 1/2" ANCHOR BOLT (4 TOTAL) TO ELECT. PANEL I _4' SCH. 40 SCOTCH COATED BLACK STEEL <br /> I FILL RISER 10' WITH FACTORY THREADS2' SCH. 40 SCOTCH COAT ( moo Q�)ENVIRONMENTAL MANAGEMENT <br /> BLACK STEEL PIPE <br /> rn PACIFIC REGION <br /> NOTE: FOR OPTIMUM INSTALLATION 2' SCH. 4 <br /> RESULTS MANUFACTURER T SUGGESTS BLACK STEr x 24' FEMALE x MALE SWNEL P�'EpACIFIC BELL FACILITY <br /> E USING ONLY FACTORY THREADED STAINLESS BRAD FLEX <br /> b NIPPLE RISERS 3` FIBERGLACONNECTOR. WE <br /> = 10 EAST 12TH STREET <br /> To TANK TRACY, CALIFORNIA <br /> EXISTING PAVEMENT SECONDARY CONTAINMENT FLEX BOOT. @RAYQ <br /> TRACCA11 UE058 <br /> � ` <br /> 3' FIBERGLASS COUPLING SYSTEMS MODEL BFR-3-30FRP-AS. EMERGENCY GENERATOR SUCTION SYSTEM <br /> EQUIPMENT BOARD <br /> a SIDE ELEVATION "A" EQUIPMENT BOARD ELEVATION <br /> TANK & PIPING DETAILS <br /> NO SCALE NO SCALE ESTIMATE/ ROUTINE ORDER: 647E 03/07/02 SCALE AS NOTED <br /> 2 TANK VENT RISER DETAIL No SCALE UE1354E DRAWN BY. SPT LwEcxeO B: MED <br /> v — (—L�Uj ARCID'fIMI • BNGR(IMG • ®YY➢tONIIBRTAL S&RYICBS sec am oRlunoN: SHEET: 4 oF: a SHEETS SHEET N0. <br /> 5 OVERFILL ALARM AND ACKNOWLEDGEMENT SWITCH BOARD AND FOUNDATION 3 SPILL BUCKET DETAIL �L�iL 1137 N. JOHNSON, <br /> ARCHBLVD. PE ALUMA, M 9H. R , CIVIL <br /> 7NGINEE0 SBC DRAWING NO.: <br /> No SCALE �%L�• B� JOHN W. JOHNSON, ARCHITECT JAMES H. RAY, qNL ENgNEER )RAC 11 -01 -0111 F4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.