EHD Program Facility Records by Street Name
>
V
>
VERITAS
>
8282
>
2300 - Underground Storage Tank Program
>
PR0504625
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2024 11:39:56 AM
Creation date
11/6/2018 11:50:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0504625
PE
2333
FACILITY_ID
FA0009285
FACILITY_NAME
AKSLAND RANCH
STREET_NUMBER
8282
Direction
E
STREET_NAME
VERITAS
STREET_TYPE
AVE
City
MANTECA
Zip
95337-9720
APN
22613019
CURRENT_STATUS
02
SITE_LOCATION
8282 E VERITAS AVE
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\V\VERITAS\8282\PR0504625\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
10/24/2017 5:04:09 PM
QuestysRecordID
3696097
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4.,�,. .T .. .: <br /> STATE OF CALIFORNI WATER RESOURCES CONTR OARD <br /> O R <br /> FORM 'B': UND GROUND STORAGE TANK PRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION '® ' <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWIN NFORMATION FOR EACH TANK. <br /> U3 <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: FARM TANK-YES NO ❑ h} <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B, C. ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL 0-1 ❑ 1 PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY jjKNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&G.A.S.# C.A.S.9 <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A.B,C,&D <br /> A.TYPE OF ❑ I DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER 5 UNKNOWN <br /> SYSTEM ❑ 2 SINGLEWALLED ❑ 4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEEL/IRON ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS 4 STEEL CLAD WI FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINU ❑ 6 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL NKNOWN ❑ 99 OTHER <br /> El RUBBER LINED El ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C. INTERIOR ❑ <br /> 'LINING 5 GLASS LINING F__] 6 UNLINED g_'Y�KNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D. CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TAR OR ASPHALT ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEELPRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM AU CONCRETE A U 7 STEEL CLAD W/FRP A U S 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P 9 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED GATE LAST USED(MO/YR) <br /> T�_MT. ESTITED QUANTITY OF 3. WAS TANK FILLED WITHSUBSANCE REMAINING IN INERT MATERIAL? ❑YES ❑ NO <br /> GALLONS <br /> THIS FORM HAS BFEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> ECO # JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> rI <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT RCHARGE AMT. FEE CODE RECEIPT <br /> VVI <br /> FORM a(6-29-88) THIS FORM MUST BE ACCOMPANIETF�A FACILITY/SITE APPLICATION, FO R M 'A',UNLESS A RRENT FORM'A' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />