My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1992-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
14175
>
2300 - Underground Storage Tank Program
>
PR0234383
>
COMPLIANCE INFO_1992-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:35 AM
Creation date
11/7/2018 12:04:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992-2005
RECORD_ID
PR0234383
PE
2361
FACILITY_ID
FA0003670
FACILITY_NAME
REYNOLDS PACKING CO QUALITY BIN
STREET_NUMBER
14175
Direction
E
STREET_NAME
STATE ROUTE 26
City
LINDEN
Zip
95236
APN
051-050-05
CURRENT_STATUS
02
SITE_LOCATION
14175 E HWY 26
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\T\HWY 26\14175\PR0234383\COMPLIANCE INFO 1992-2005.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
274
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br /> SWR , January 2002 Page of <br /> C� <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tann Manufacturer ❑Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum ❑Hydrostatic <br /> ❑Other(Specie) <br /> Test Equipment Used: Dwyer Manometer Equipment Resolution: -1-/-2% <br /> Tank# 1 Tank# Tank# Tank# <br /> "TExempt From Testing?' ❑Yes xNo Yes ❑No ❑ Yes Ll No 11 Yes ❑No <br /> Tank Capacity: 12,000 <br /> Tank Material: Fiberglass <br /> Tank Manufacturer: Unknown <br /> Product Stored: Diesel/Regular <br /> Wait time between applying <br /> pressure/vacuum/water and 30 Min <br /> starting test: <br /> Test Start Time: 9:00 <br /> Initial Reading(Rj): 9.55 <br /> Test End Time: 10:00 <br /> Final Reading(RF): 9.37 <br /> Test Duration: I Hour <br /> Change in Reading(RF-Rl): 1$ <br /> Pass/Fail Threshold or Criteria: No less I"drop <br /> Test Result: x Pass ❑Fail ❑ Pass Ci Fail ❑ Pass Q Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? x Yes ❑No C]NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and x Yes ❑No ❑NA ❑yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment, such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> t&otints f(-'alifnrnia f'nr�a of Rrnilatinnc Titles 72 Qnrtinn 7h27falf(.1! <br />
The URL can be used to link to this page
Your browser does not support the video tag.