26 (STATE ROUTE 26)
>
14175
>
2300 - Underground Storage Tank Program
>
PR0234383
>
COMPLIANCE INFO_1992-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:35 AM
Creation date
11/7/2018 12:04:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992-2005
RECORD_ID
PR0234383
PE
2361
FACILITY_ID
FA0003670
FACILITY_NAME
REYNOLDS PACKING CO QUALITY BIN
STREET_NUMBER
14175
Direction
E
STREET_NAME
STATE ROUTE 26
City
LINDEN
Zip
95236
APN
051-050-05
CURRENT_STATUS
02
SITE_LOCATION
14175 E HWY 26
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\T\HWY 26\14175\PR0234383\COMPLIANCE INFO 1992-2005.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
274
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUN-17-2003 02 :02 PM WLDSPHARPER & CO. MOD 236as�0185 P. 03 <br /> = OPW 61 SO OVERFILL PREVENTION VALVES <br /> Ordering Specifications and Dimensions <br /> Product! Dolloription A4JWr Tube &Lower Tube 'C Overall Mo.Tank Max.Nominal Malt.Actual <br /> suffix No. Length Langth Longth Riser Length Took 01a. Tank Dia. walght <br /> In. m. in. m� In .m, In. M. in. In. in. M. In. kg, lilt Price <br /> _�.. - <br /> 6180 30� 3"N"aint O9` 1.6 t3" 2,1_ 165Y" 1.9 53T 1.4 96° _2 d 19B' 2f 13 i_ _ S. <br /> 6150.1400 Grooved-tube 60" 1.5 83° 2.1 13411 3.9 53'14' 1.4 96' 2.4 197' 2.7 17 8 9135.33 <br /> 6150.1000 _CARE,Grooved-tube 60" 1.5 83" 2.1 15411" 3.9 5315" 1.4 96" 24 107"_ 2.7 17 8 3515.70 <br /> 61so4m 41'm-pond 60" 1.5 83 <br /> � '--1115,411" 39 53%' 1.4 g6" 24 107" 27 16 7 $455.10 <br /> 6188.1010 4"two-point 120" 3.1 102" 26 2331{" 5.6 1133" 23 120" 11 126" 3.2 26 ti 5503,30 <br /> 0 4940 GARB 4",two-point 60" 1,5 83" 2.1 15431" 3.9 53r 1.4 96" 2A 107, 2.7 16 7 $412.40 <br /> 615 <br /> 6150.410C CARS r,two-point 120" 311 102" 216 M)e, 6.1 113Yr" _ 3.2 25 11 sm.'oo <br /> 61S0-420C CARS Ct■ro"polnt 120" 3.1 126" 3-2 257%" 6.5 113;5" 29 144" 3.7 150' <br /> 3.1 28 12 5581.90 <br /> 6180.1901 C'KPNA two-point 60" 14 83" 2.1 15411" 39 5314" 1.4 g6" 2A 107" 2.7 17 8- $470.15 <br /> 6150.4900 4"KlwAvaW-tight 80" 15 03" 2.1 16411" 3.9 53X" 1.4 96" 2.4 for 2.7 16 " 7 5511.30 <br /> 6190x44121'1 Two-point methanol 120" 3.1 not included 23331" 5 9 113Y4" 2,9 120" 3.1 126" 3-2 25 11 <br /> 61SOM-412C'1 CARS 4',two-point 120" 7..1 not included 2336" 149 11311" 2.8 120' 11 126" 31 25 11 $940.11! <br /> 61SOC4001 Coaxial 60" 1.5 83" 2.1 15431" 3.0 63'h" 1A 06' 2.4 107" 2.7 16 1 S543.30 <br /> 61800 4011 Coaxial _ 120" 3:1 102" 218 23331" 3,9 113r 2.9 120" }1. 126" 3.2 26 11 95$4.69 <br /> 61SW3�412 CARE, .coaxial 108" 2.7 B Y 26 7111(" Sfi.53r 2.1 124"L4+ 126" 3,2 27 �p 7.14 y <br /> 6150Pa002 CARE,pop.coaxial 60" 1,5 83" 21 15411" 3.0 5314" _ 1,4 96" 21 _107" 2.7 20 8 <br /> PoP 57!10.35 <br /> 61SOCM4000">: Coaxial,MdAnol 120" 3.1 not included 233%, 5,0 113)1° 2.9 120" 9,1 126' 3,2 25 11 $734.20 <br /> 0150.48YT overill valve only,no drop tubes supplied SM.50 <br /> 613 41SYT K11 to adapt 6180.49YT for coaxial applicationb 3 354.45 <br /> 6180114000" Remote 72" t,b 03" 21 161%'- 4.2 8512" 1.1 96" 2.4 for 2.7 10 0 51110.20 <br /> 61SORM 40III-IRemote,methanol 72" 1.8 not Included 18511"_ 4.7 65%, 1,7 120" 3.1 126" 3.2 19 _.4.. $926,80 <br /> 'For ueeedth MES 6 xN00 rrnthend Pude "'R■mMe fill applkMlons "'hsmote tat,Mathend <br /> Methanol modeh do Trot Include laeer drop tuba Adipibr*3"0.Smith Flbergisee Pipe(Drop To4e1 is Included-Appropriate length of 3"A.O.Smith Aberglree Pipe In r Irod <br /> for lower Drop Tutor Irbt 1umYhed3. r <br /> Typical Application Assembly Replacement Parts <br /> Installation schematic typical;exact dirnent Dns Mil vary with tank configuration. ust <br /> 1`01110. Description 'Price <br /> OPW 1.2100 Opw 134TT <br /> .� . ..•- •,•, 6150160001 PberKit_ 51119 <br /> Cap <br /> Cts Tw"otnt irdet lube 318 50 <br /> CO3M Coulal We[tube $31,90 <br /> h , OPW 1.2100 c. <br /> l 0Pw 6337 i <br /> Adaptor <br /> Trap Door <br /> „u A Underground Amex <br /> Max tank typical <br /> �r <br /> e 4•8"tong d"NPT Nipple s t <br /> min <br /> C <br /> Max <br /> min " Underground <br /> 1114" tank,typical <br /> 77 <br /> ¢' OPW 61SO Overfill Prevention <br /> 9 Max local <br /> end cut per Valves are covered under the <br /> local requirementx following patent;#4,986,320. <br /> T Re:#33,555 and Canadian patent <br /> 6" a Max <br /> u`x Tube and cut par #1,287,54$,Other patents pending. <br /> I toed roquinmwnt■ <br /> DPW 6190.4000 DPW 61SOR-4000 <br /> "From Inside wall of tank to bottom of upper tuba <br /> s° <br />
The URL can be used to link to this page
Your browser does not support the video tag.