Laserfiche WebLink
STATE OF CALIFCRIM WATER RESOURCES CONT 900ARD <br /> FORM `B': UNDERGROUND STORAGE TANK PR GRAM <br /> TANK PERMIT APPLICATION INFORMATION <br /> TANK <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWIN INFORMATION FOR EACH TANK. <br /> MARK ONLY F—] 1 NEW PERMIT 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED T K <br /> ONE ITEM El INTERIM PERMIT El AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED 1 n� <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: ��U Y (r j NFARM TANK-YES❑ NO ^ <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY <br /> A. OVVNERS TANK ID# B. MANUFACTURED BY: �'j �7 � <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: 7y U'/ <br /> II. TANK C NTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,C PLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. 1 UNLEADED [:] 2 LEADED ❑ 3 DIESEL <br /> F—] 3 CHEMICAL PRODUCT F—] 4 OIL L_J " PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW( <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.q C.A.S 11', <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&0 <br /> A.TYPE OF _ DOUBLE WALLED F__] 3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM 2 SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> 1 STEEL/IRON ❑ 2 STAINLESSSTEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD WIFIBERGLASS REINFORCED PLASTIC <br /> B.TANK 5 CONCRETE ❑ 6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑ B 1 DO%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> F-11 RUBBER LINED E] 2 ALKYD LINING ❑ 3 EPDXY LINING A PAENOLIC LINING <br /> C. INTERIOR 5 GLASS LINING 6 UNLINED 95 UNKNOWN <br /> LINING ❑ ❑ <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D. CORROSION ❑ 1 POLYEfHLENEWRAP ❑ 2 TAR OR ASPHALT 03 <br /> ,P'rYLWRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑ 91 NONE Dr9595 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF AB VE GROUND, U IF UNDERGROUND,BOTH 1F APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A(Uj 2 PRESSURE A U 3 GRAVITY A U 91 NONE A 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A(U)95 UNKNOWN A U 99 OTHER <br /> A U 1 STEELIIRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C.MATERIAL A U 5 ALUMINUM A 6 CONCRETE A U 7 STEEL CLAD W/FRP A U B 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 5 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> Q S i VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S I ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S I PREGISIONTESTIN 5 7 PRESSURETESTING P S 91 NO <br /> P 5 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF =INERT <br /> FILLED WITH <br /> SUBSTANCE REMAINING IN ERIAL? ❑YES ❑ NO <br /> GALLONS <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> IF <br /> :LOCAL <br /> JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> / ! Z- o U <br /> AGENCY FACILITY ID# APPROVV/ED BYM,, PHONE#WITH AREA CODELAI PERMIT APPROVAL DATE PERMIT EXPIRATIO DATE <br /> PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FORM `A' UNLESS A - RENT FORM"A' HAS BEEN FILED f <br /> 8-29-88) THIS FORM MUST BE ACGOMPANI A FACILITYlSiTE APPLICATION, , <br /> DATA PROCESSING COPY <br />