My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1985-2000
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WASHINGTON
>
2201
>
2300 - Underground Storage Tank Program
>
PR0231282
>
BILLING 1985-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2021 10:59:25 PM
Creation date
11/7/2018 8:31:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985-2000
RECORD_ID
PR0231282
PE
2381
FACILITY_ID
FA0003909
FACILITY_NAME
PORT OF STOCKTON
STREET_NUMBER
2201
Direction
W
STREET_NAME
WASHINGTON
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14503001
CURRENT_STATUS
02
SITE_LOCATION
2201 W WASHINGTON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WASHINGTON\2201\PR0231282\BILLING 1985-2000.PDF
QuestysFileName
BILLING 1985-2000
QuestysRecordDate
8/16/2017 4:58:49 PM
QuestysRecordID
3583937
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
117
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFOR11 <br /> WATER RESOURCES CONT OAR® <br /> STORAGE TANK PR GRAM =� s <br /> FORM B . UNDERGROUND - _ <br /> TA� TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. z <br /> 10 <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 P NENTLY fL0 TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT 1-14 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE TANK REMOVED N <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: Zjf Gj f FARM TANK-YES❑ NO <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY I <br /> A. OWNERS TANK ID 9 B. MANUFACTURED BY: <br /> too <br /> C. YEAR INSTALLED D TANK CAPACITY IN GALLONS: <br /> II. TANK PONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. V, MOTOR VEHICLE FUEL ❑ 2 PETROLEUM Vl <br /> C. ❑ 1 UNLEADED 2 LEADED ❑ 3 DIESEL <br /> 1:13 CHEMICAL PRODUCT ❑ 4 OIL ODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.N C.A.S. . <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑ 1 OUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLEWALLED ❑ 4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> 1 STEEL(IRON ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD WIFIBERGLASSREINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑ B 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> 1 RUBBER LINED El ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C. INTERIOR <br /> LINING F-] 5 GLASS LINING F-] 6 UNLINED 5 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TARORASPHALT ❑3 LWRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION E] 5 CATHODIC PROTECTION E] 91 NONE 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMA ON CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINEDTRENCH A U 91 NCNE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A A 6 CONCRETE A U 7 STEEL CLAD W1 FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. 'LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> 1 VISUAL CHECK P 5 2 INVENTORY RECONCILIATION P S 3 VAOOSE WELLS P 5 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> 6 PRECISION TESTING 5 7 PRESSURETESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 7. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED OUANTITY OF 3. WAS TANK.FILLED WITH <br /> SUBSTANCE REMAINING IN INERT MATERIAL? ❑YES ❑ NO <br /> GALLONS <br /> TN1S FORM FIRS BEEN COMPLETED UNDER PENALTY OF PERJURY AND TO THE BEST DF MY KNOWLEDGE, fS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# ,/� T�A^7NK IDS# <br /> V [� V <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME� PHONE#WITH AREA CODE <br /> U�(1 � C' <br /> PERMIT NUMBER PERMIT APPROVAL DA PERMIT EXPIRATION DATE <br /> CHECKS PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FORM B(6-29-BB) THIS FORM MUST BE ACCOMPANIEu A FACIL1TYISITE APPLICATION, FORM `A',UNLESS A RENT FORM`A' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.