r <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209) 468-3433 Web:www.sjgov.or_la ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> ALPHA FAST GAS* 209 462-4569 Aril 23 2015 <br /> Facility Address: CERS ID: <br /> 2358 E WATERLOO RD STOCKTON CA 95205 10182079 <br /> Inspection Contact: Title: Phone: <br /> Jimmy Nguyen Mana er 209 462-4569 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION -O eratinIJimmy <br /> ermit 12361 - UST FACILITY <br /> Consent For: Consent Given By: <br /> Inspection Photos Sam linNguyen, Mana er <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Dave Winkler 03103/2016 Ed Stearns 03/06/2016 <br /> Service Technician Manufacturer's Training <br /> Veeder-Root Level 4 02/10/16-1 VMI Tester,11/10/15 <br /> CCR=Califomia Code of Regulations HSC=Health and Safety Code GFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate n V ❑R ❑COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system o V ❑R ❑COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted ❑V n R ❑COS <br /> 104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current ■V ■R ❑COS <br /> 105 HSC 25266(c) Current BOE number not submitted n V ❑R ❑COS <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD ■V ■R L COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ■V ❑R ❑COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing ❑V e R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment n V c R u COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days ❑V ❑R n COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually ❑V o R e COS <br /> 112 HSC 25284.2 Failed to test spill containers annually o V o R ❑COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days ❑V a R ❑COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down c V c R u COS <br /> 115 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days L V ❑R ❑COS <br /> 116 CCR 2715 Designated operator, service tech or installer did not possess current ICC certification ❑V c R ❑COS <br /> 117 HSC 25292.5 Failed to conduct ELD testing on a system located within 1000'of a public well Li V n R ❑COS <br /> 118 HSC 25292.5 Failed to repair and retest system due to failed ELD test ❑V c R L COS <br /> 119 CCR 2644.1(a)(5) Failed to submit ELD test results within 60 days ❑V e R c COS <br /> 120 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after o V e R L COS <br /> rl <br /> 1 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests ❑V c c n R e COS <br /> 2 HSC25299 Documents were falsified or misrepresented n V R COS <br /> 3 CCR 2661 Permit to repair UST system not obtained ❑V ❑R n COS <br /> 124 CCR 2635(d) Failed to submit UST Certification of Installation/Modification ❑V o R ❑COS <br /> Received by Inspector: Phone: Date: <br /> (initial): STACY RIVERA, Senior REHS (209)468-3440 04/23/2015 <br /> Page 1 of 6 <br />