COMPLIANCE INFO 2013 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
2358
>
2300 - Underground Storage Tank Program
>
PR0231756
>
COMPLIANCE INFO 2013 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 4:59:40 PM
Creation date
11/7/2018 9:03:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2016
RECORD_ID
PR0231756
PE
2361
FACILITY_ID
FA0006343
FACILITY_NAME
ALPHA FAST GAS*
STREET_NUMBER
2358
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
14118221
CURRENT_STATUS
01
SITE_LOCATION
2358 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WATERLOO\2358\PR0231756\COMPLIANCE INFO 2013 - 2016.PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2016
QuestysRecordDate
8/8/2018 4:42:56 PM
QuestysRecordID
3958640
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
117
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 6 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siclov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility Alpha Fast Gas Facility Inspection <br /> Name: p address: 2358 Waterloo, Stockton <br /> Date: Apr 23, 2Q14 <br /> Facility Title: <br /> Contact: Nina Bichthy Nguyen owner fteb12-8077 <br /> Inspection <br /> Type: X Routine X Monitoring System Certification J Installation i I Complaint-ID#: L�Other: <br /> (Authority HSC 25289) <br /> Consentfor. Xlnspection Sampling XPhotos Grantedby:Jimmy Nguyen Title: owner <br /> Monitoring Gilbareo EMC <br /> LP,Y.t mXPressurized ❑Suction 17 Gravity Prevention: XMechanical r Audible/visual <br /> UST 4 5 ;m. <br /> - Product - 87-octane 91-octane- ----------- <br /> DSL- -- -------------- ------------- -------------- ----------- -- ------------ ---------- - - <br /> Opel ator., Felix/Dave W Affordtest Icc Exp. <br /> Or { Date: Violations: YM1-Release Detection M2-Release Prevention G M3-Bath <br /> On Site Service ICC Exp. Manufacturer's <br /> Technician: Felix Ramirez Date; 12/6/2014 Training: VMI #2516 11112115; VR 6/2512014 <br /> VIOLATIONS <br /> # C t C2 M Code Section HSC=California Health and Safe Code;CCR=California Code of Re Mations <br /> C1 =Class 1 violation;C2=Class 2 viciation;M=Minor violation <br /> File Review <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks stern <br /> 104 X HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification <br /> not provided to the EHD at least 48 hours priorto conducting t st <br /> Monitoring equipment certification:(a)not performed annually; st report not submitted within 30 days; <br /> 109 X CCR 2638 (e)test notification not provided to the EHD at least 48 hours prl to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(f) Annual line leak detector test not performed (Mi) <br /> 111 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or-fail safe not present (Mi) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> permit conditions <br /> 116 HSC 25292,5 Enhanced leak detection(ELD)testing not performed on a system located within 1 000'of public well,or <br /> failures not repaired and retested <br /> 117 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when LIST storage andlor monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 120 HSC 25298(c) Permit to close UST system not obtained <br /> On Site Records <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6 Y2 years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 X CCR 2712(b) �) <br /> upgrades for the life of the tank. Monitoring1 records include: ate and time of all monitoring or sampling; <br /> monitoring equipment calibration and maintenance records,, results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment, round water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 CCR 2712(i) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (Mi) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned ul after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> rJ <br /> pector. Received By:effrey Wong (209) 468-0335 <br /> EHD 23-02 Rev 04119112 Page 1 US NS CTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.