My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
2358
>
2300 - Underground Storage Tank Program
>
PR0231756
>
COMPLIANCE INFO 2013 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 4:59:40 PM
Creation date
11/7/2018 9:03:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2016
RECORD_ID
PR0231756
PE
2361
FACILITY_ID
FA0006343
FACILITY_NAME
ALPHA FAST GAS*
STREET_NUMBER
2358
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
14118221
CURRENT_STATUS
01
SITE_LOCATION
2358 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WATERLOO\2358\PR0231756\COMPLIANCE INFO 2013 - 2016.PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2016
QuestysRecordDate
8/8/2018 4:42:56 PM
QuestysRecordID
3958640
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
117
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.slgov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Alpha Fast Gas l=acirity 2358 E. Waterloo, Stockton Inspection A r 25, 2013 <br /> Name: p Address: Date: p <br /> VIOLATIONS <br /> # Cf C2 M Code Section HSC=CA Health and SafeV Code;CFR=Code of Federal Regi <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (Mi) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) {M�) <br /> Other Violations <br /> 999 X Other: See attached"Continuation—Official Inspection Report'for violation(s)not listed above. <br /> SUMMARY OF <br /> GLASS I,CLASS II,<r MINOR-Notice to comili <br /> This is a report of the Routine and Monitoring System Certification inspection conducted at the <br /> referenced facility by San Joaquin County Environmental Health Department (EHD). The following are <br /> Class II Repeat Violations: 104, 206,303,305, and the following is a Minor-Notice to Comply: 999 <br /> 104. (Repeat) Financial responsibility documents have not been submitted to the EHD. Current financial <br /> responsibility documents are required to be submitted annually. A copy of current financial <br /> responsibility documents were provided to EHD during this inspection. Violation was corrected on site. <br /> 206. (Repeat) Documentation for the designated operator employee training for 2013 was not available <br /> or did not exist . The designated operator shall train facility employees for which he or she is <br /> responsible in the proper operation and maintenance of the UST system once every 12 months. The <br /> training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact persons) for emergencies and monitoring equipment alarms <br /> A copy of the current training documents signed today was provided to EHD by designated operator <br /> during this inspection. Designated operator stated training was performed but owner appeared to have <br /> misplace the document. Ensure that employees have been trained by the designated operator, and <br /> maintain the list and training documentation on site. Violation was corrected on site. <br /> 303. (Repeat) The date on the Monitoring Panel and the last three alarm history of all the sensors were <br /> incorrect around beginning around February 2013, possibly a result of installing a new panel and cold <br /> start during the same month, and therefore is not working properly to ensure continuous monitoring of <br /> the tank system as required by CCR 2630(d). The correct date on the Monitoring Panel was input by <br /> the technician on site. Violation was corrected on site. Ensure monitoring system is working properly at <br /> all times. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT Ei CURRENT HOURLY RATE. <br /> Inspect Received By: Title: <br /> EH 3-0 04119/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.