Laserfiche WebLink
SWRCB, January 2002 0 RECageIPV/ oD <br />7. UNDER -DISPENSER CONTAINMENT UDC TESTING <br />Test Method Developed By: 11 UDC Manufacturer ❑ Industry Standard X ProfessiW 61 <br />onal Engineer <br />11 Other (Specify) C AI HEAL <br />.. <br />Test Method Used: Vacuum ydroctati�A ...— <br />El Pressure 7 X H <br />❑ Other (Specify) U t RTMENT <br />Test Equipment Used: Caldwell Level Change Indicator <br />UDC # 1&2 -RT UDC # 3&4 -RT <br />UDC Manufacturer: Bravo Bravo <br />Equipment Resolution: .002 <br />UDC # 5&6 -RT <br />UDC # 7&8 -RT <br />Bravo <br />Bravo <br />UDC Material: <br />Coated Steel <br />Coated Steel <br />Coated Steel <br />Coated Steel <br />UDC Depth: <br />10" <br />10" <br />10" <br />10" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />See Comments <br />See Comments <br />See Comments <br />See Comments <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />See Comments <br />See Comments <br />See Comments <br />See Comments <br />Condition of UDC prior to <br />testing: <br />Dry <br />Dry <br />Dry <br />Dry <br />Portion of UDC Tested <br />Water Level 8" <br />Water Level 8" <br />Water Level 8" <br />Water Level 8" <br />Does turbine shut down when <br />UDC sensor detects ]iquid (both <br />roduct and water)?' <br />No <br />No <br />No <br />No <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />safe shutdown? <br />yes <br />Yes <br />Yes <br />Yes <br />Was fail-safe verified to be <br />operational?* <br />No <br />No <br />No <br />No <br />Wait time between applying <br />water and starting test <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />Test Start Time: <br />12:50 <br />12:55 <br />1:00 <br />1:05 <br />Initial Reading (R,): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test End Time: <br />1:20 <br />1:25 <br />1:30 <br />1:35 <br />Final Reading (RF): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test Duration: <br />30 Minutes <br />30 Minutes 1 <br />30 Minutes <br />30 Minutes <br />Chane in Reading R,-Ri): <br />0 <br />0 1 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />Test Result: <br />Pass <br />Pass <br />Pass <br />Pass <br />Was sensor removed for testing? <br />No <br />No <br />No <br />No <br />Was sensor properly replaced and <br />verified functional after testing? 11 <br />N/A <br />N/A <br />N/A <br />N/.4 <br />Comments — (include information on repairs made prior to testing, and recommendedfollow-up forfailed tests) <br />All Penetrations enter from bottom of Bravo System UDC's. <br />RT=Retail Island. <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />'H <br />