My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4407
>
2300 - Underground Storage Tank Program
>
PR0231761
>
COMPLIANCE INFO 2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 4:34:37 PM
Creation date
11/7/2018 9:23:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0231761
PE
2361
FACILITY_ID
FA0002347
FACILITY_NAME
ERNIES GENERAL STORE
STREET_NUMBER
4407
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710059
CURRENT_STATUS
01
SITE_LOCATION
4407 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WATERLOO\4407\PR0231761\COMPLIANCE INFO 2011-2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SAN JOAQUIN COUNTY • <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siaov.orD/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Fame) Ernie's General Store <br />Name: <br />Facility 4407 Waterloo Road, Stockton <br />Address: <br />"sp�'"10" Jan 15, 2013 <br />Date: <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code SeatonHSC <br />= CA Heakh and Safety Code; CFR = Code of Federal R19,1,11ons <br />C1 = Class 1 violation; C2 = Class 2 vlonsion; M = Minor Nolalion <br />On Site Records (continued) <br />204 <br />205 <br />CCR 2715(c) Designated Operator monthly inspection: (1) alarms not documented; (24) spill containers, UDCs, and sumps <br />if necessary)not inspected; 5 reuired test dates not checked or noted; 6 em to ee trainin not verified <br />CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months <br />206 <br />CCR 2715(f) Designated operator employee training: (1) not performed; (2) not current for at least one employee on site; <br />3 to not ke t <br />207 <br />HSC 212-1.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br />observations <br />301 HSC 25292.1 UST system is not operatetl to prevent unauthorized release, including spills and overfills <br />302 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary containment@N) <br />303 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (M7) <br />304 CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST (M1) <br />305 CCR 2636(1)(1) Failed to maintain a continuous monitoring system for underground piping & UDCs that activates an (M1) <br />audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br />306 CCR 263 (a) Primary containment is not product tight <br />307 HSC 25291(a)(2) Secondary containment for UST system is not fight <br />308 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br />309 1 CCR 2636(a) Failed to have secondary containment for piping (includes conventional suction piping) (M2) <br />310 HSC 25291(a) Water in 2- containment not removed, analyzed & property disposed of <br />--3, <br />1 CCR 2636(f)(2) Line leak detector(s) not installed or failed to detect a 3 -gallon per hour leak at 10 psi (M1) <br />312 CCR 2635(b) No spill container or overfill prevention system installed (111112) <br />313 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons, or failed to provide a means to keep (1112) <br />the spill container em <br />314 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements (111112) <br />—T, —5 <br />HSC 25299(f)(2) Tampering with or disabling leak detection devices or alarms <br />316 CCR 2631.1(a) UST system is not compatible with the substance stored <br />317 HSC 25298(a) Illegally abandoned UST system <br />AB 1702 (2003-2004) HSC 25290.1 (installed between 07/01/03 and 06/30/04) <br />VPH Systems HSC 25290.1 installed on or after 07/01/04 <br />401 <br />CCR 2631.1 <br />Compatibility and permeability requirements: (a) UST system is not compatible with the substance stored; (b) <br />results of the compatibility and permeability testing requirements listed in subsections CCR 2631(b) and (d) <br />for a UST system installed after July 1, 2004, were not submitted <br />402 <br />HSC 25290.1(c)(1) <br />HSC 25290.2(c)(1) <br />Primary containment not liquid or vapor tight <br />403 <br />HSC 25290.1(c)(2) <br />HSC 25290.2 c 2 <br />Secondary containment not liquid or vapor tight <br />404 <br />HSC 25290.1(c)(3) <br />HSC 25290.2(c)(3) <br />Secondary containment not constructed to prevent water intrusion <br />405 <br />HSC 25290.1(d) <br />HSC 25290.2 d <br />Monitoring system not maintained to detect water intrusion into the secondary containment, or the entry of <br />It uid or va or from the rima containment into the secunda containment <br />406 <br />HSC 26290.1(a) <br />Interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial space of the <br />UST s tem not maintained <br />407 <br />HSC 25290.10) <br />HSC 25290.2 i <br />UST system not tested by one of the following methods prior to use: (1) Enhanced leak detection; (2) inert gas <br />ressure testa roved b SWRCB; 3 test method deemed equivalent to 1 or 2 b the SWRCB <br />Emergency Generator Systems <br />501 <br />CCR 2636(1)(6) <br />Emergency generator monitoring system not checked daily or log not kept 8 no leak detector (M7) <br />502 <br />HSC 25281.5(b)(3) <br />Unburied fuel piping not visually inspected at least monthly or log not kept (M1) <br />USTs in a Vault <br />601 HSC 25283.5(a)(1) All exterior surfaces of the tank and connected piping cannot be directly viewed <br />602 HSC 25283.5(0)(2) Structure that the UST is located in does not provide for secondary containment <br />603 1 HSC 25283.5(a)(3) Failed to conduct weekly UST inspections or maintain a log of weekly inspections <br />604 HSC 25283.5(a)(5) UST installed after July 1, 2003, does not meet or exceed applicable sections of HSC 25291 <br />Non -Pressurized Piping <br />701 CCR 2643(d) Daily monitoring of suction piping (pre -January 1, 1984) not performed (M1) <br />Ingpepar <br />Garrett Backus (209) 468-29862 <br />Recei <br />rme: <br />tnU 2302 Rev 04/19/12 rage 2 1 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.