Laserfiche WebLink
January 26, 1989 <br /> Re-Excavation Work Plan (option #1) <br /> I. Site Location: Union Ice Company <br /> 1320 W. Webber <br /> Stockton, CA <br /> II. Thortec Project Manager: Steve Furnas <br /> 16301 Spring Creek Dr. <br /> Ripon, CA 95366 <br /> (209) 559-3512 <br /> III . Excavation Contracts: Semco <br /> 431 W. Hatch Road <br /> (Contracting License Modesto, CA 95351 <br /> 449864-A,B,C-61) (209) 524-9653 <br /> IV. Certified Laboratory: California Water Lab <br /> P.O. Box 9249 <br /> Authorization for release Modesto, CA 95352 <br /> of Data Form Enclosed. (209) 527-4050 <br /> V. Drilling Contractor: Sierra Drilling <br /> 611 South 9th Street <br /> Modesto, CA 95351 <br /> (209) 575-2870 <br /> VI . History: <br /> This site had four underground fuel tanks on the <br /> property. One containing diesel, three containing <br /> gasoline. These tanks were used exclusively by Union Ice <br /> company for their own vehicles, or by Don's Distributing <br /> for his vehicles. No outside retail sales for fuels <br /> occurred at this site. <br /> Preliminary lab data obtained at the time the tanks were <br /> removed, indicate unleaded gasoline and small amounts of <br /> diesel has leaked from one or more of the tanks. <br />