My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEBER
>
2435
>
2300 - Underground Storage Tank Program
>
PR0231286
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/9/2024 1:56:07 PM
Creation date
11/7/2018 9:48:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231286
PE
2381
FACILITY_ID
FA0003036
FACILITY_NAME
COMMERCIAL SALVAGE
STREET_NUMBER
2435
Direction
E
STREET_NAME
WEBER
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
15323117
CURRENT_STATUS
02
SITE_LOCATION
2435 E WEBER AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WEBER\2435\PR0231286\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
10/2/2017 6:04:48 PM
QuestysRecordID
3656497
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA • <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B oM1 <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. 1 <br /> [DBA;ORI <br /> ONLY ❑ 1 NEW PERMIT c• <br /> ITEM ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION I� <br /> ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ L ,7 PERMANENTLY CLOS N SITE <br /> 6 TEMPORARY TANK CLOSURE /�ijo`I <br /> FACILITY NAME WHERE TANK IS INSTALLED: a $ 8 TANK REMOVED /. <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN V <br /> A OWNER'S TANK I.D.Y <br /> B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYNEAR) q T <br /> D. TANK CAPACITY IN GALLONS- <br /> 11.II.TANNKy CONTENTS IFA-1 IS MARKED,COMPLETE ITEM C. <br /> A �L 1 MOTOR VEHICLE FUEL ❑ 4 OIL B <br /> C. [—jlaREG <br /> 2 PETROLEUM ULAR UNLEADED 3 DIESEL ❑ 6 AVIATION GAS <br /> ❑❑ E] 80 EMPTY �4-PRODUCT ❑ 1b PREMIUM UNLEADED 4 GASAHOL ❑ 7 METHANOL <br /> 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ is MIDGRADE UNLEADED ❑ 5 JETFUEL ❑ 8 M85 <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED ❑ 2 LEADED ❑ 99 OTHER(DESCRIBE IN ITEM D.BELOW) <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C.AND ALL THAT APPLIES IN BOX D AND E C.A S.Y: <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER <br /> ll�2 SINGLE WALL ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> 4 SINGLE WALL IN A VAULT <br /> ❑ 99 OTHER <br /> B. TANK K, BARE STEEL ❑ 2 STAINLESS STEEL <br /> MATERIAL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> ❑ 5 CONCRETE E] 6 POLYVINYL CHLORIDE 7 ALUMINUM <br /> (Primary Tank) El 9 BRONZE ❑ ❑ 8 1METHANOL COMPATIBLE W/FRP <br /> ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN OTH <br /> ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING <br /> LINING OR 555y����..,,,////6 ❑ 3 EPDXY LINING E] 4 PHENOLIC LINING <br /> ❑ 5 GLASS LINING IJKI UNLINED <br /> COATING �'""� ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ NO <br /> RIOR <br /> D CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING <br /> I��g ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION 1 NONE ❑95 UNKNOWN <br /> E.SPILL AND OVERFILL,6IC. SPILL CONTAINMENT INSTALLED q) ❑ 99 OTHER <br /> DROP TUBE YES NO PLATE YES OVERFILL PREVENT) EQUIPMENT INSTALLED(YEADISPENSER CONTAINMENT YES_ NO <br /> R) <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR Up UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION <br /> A U 2 PRESSURE A U 3 GRAVITY <br /> B. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 4 F BLEPIPING A U 99 OTHER <br /> A U 3 LINED TRENCH p U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL p <br /> U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U S ALUMINUM <br /> PROTECTION A U 6 CONCRETE A U 7 STEELW/COATING <br /> A UO9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 8 100% METHANOL COMPATIBLE W/FRP <br /> D. LEAK DETECTION ❑1 Dl� 4TCTE� uNE)FAN 2 TFSTING 3 CQVTINUON6 LINE N.-M-S$ A U 95 UNKNOWN A U 99 OTHER_ <br /> FAX DETECTOR❑ INTEPSR11gL O 1 ELECmGM UNE ❑5 At%WVC1yN WMT El 99 OTHER <br /> V.TANK LEAK DETECTION Nox9URINa tSHUIOp <br /> ❑ 1 VISUAL CHECK 8 VADOZE <br /> MANUAL INVENTORY <br /> ❑ 3 MONITORING 4 AUTOMATIC TANK 5 GROUND WATER 6 ANNUAL TANK <br /> ❑ 7 CONTINUOUS INTERSTITIAL ❑ GAUGING ❑ <br /> MONITORING ❑ 8 SIR ❑ 9 WEEKLY MANUAL ❑10 MONTHLY TANK MONITORING TESTING <br /> Vi.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE)NK GAUGING TESTING ❑ 95 UNKNOWN ❑ 99 OTHER <br /> 1.ESTIMATW DATA LA$'{USED YNR) 2.ESTIMATED QUANTITY OF y�y, <br /> v SUBSTANCE REMAINING G!O GALLONS 3 WAS TAN FILLEDMATERIWI, <br /> H YES ❑ NO �I <br /> TI-11S FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> [—TAN OWNER'S NAME <br /> (PRINTED 6 SIGNATURE) <br /> DATE <br /> LOCAL AGENCY USE ONLY THESTATEI.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# <br /> STATELD:# � TANK# <br /> PERMIT NUMBER <br /> PERMIT APPROVED BYAJATE <br /> PERMIT EXPIRATION DAT <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PIfILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE RGROUND STOP GE TANK REGULATIONS <br /> FORM B (6-95) <br />