My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4747
>
2300 - Underground Storage Tank Program
>
PR0232482
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2024 2:38:22 PM
Creation date
11/7/2018 10:23:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232482
PE
2361
FACILITY_ID
FA0003719
FACILITY_NAME
WEST LANE CHEVRON
STREET_NUMBER
4747
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10437010
CURRENT_STATUS
01
SITE_LOCATION
4747 WEST LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WEST\4747\PR0232482\BILLING 1990-2003.PDF
QuestysFileName
BILLING 1990-2003
QuestysRecordDate
1/23/2018 4:55:33 PM
QuestysRecordID
3768664
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIN WATER RESOURCES CONTR4901ARD <br /> FORM B': UNDERGROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> IC <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED:CF.EVRON USA-4747 WEST LANE, STOCKTON FARMTANK-YES❑ NO 199N <br /> N <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY F� <br /> A. OWNERS TANK ID# UNKNOWN ¢ B. MANUFACTURED BY: , IM N <br /> C.YEAR INSTALLED (090 D. TANK CAPACITY IN GALLONS: 12,000 <br /> 11. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. I UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL x 1 PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF C.A.S.#: <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,A D <br /> A TYPE OF ®1 DOUBLEWALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLEWALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEEUIRON ❑2 STAINLESS STEEL ®3 FIBERGLASS ❑4 STEEL CLAD INIFIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE F-] 6 POLYVINYLCHLORIDE El7 ALUMINUM ❑ 8100%METHANOL COMPATIBLE FRP �f�N <br /> MATERIAL J i lEc l Y: <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL [:] 95 UNKNOWN ❑99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING �JI�UI pL 21,I 5A19L9� <br /> C. INTERIOR 5GLASS LINING ®6UNLINED El 95 UNKNOWN i=1VVIRONIYIENTALI"I -A�.� �'� <br /> LINING ❑ V Y <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑ 99 OTHER .. <br /> D. CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TARORASPHALT ❑ 3 VINYL WRAP ® 4 FIBERGLASS REINFORCED PLASTIC J <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A<0 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A DOUBLE WALLED A U 3 LINEDTRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5ALUMINUM A U 6CONCRETE A U 7STEEL CLAD W/FRP A U 8100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3VADOSE WELLS PO4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> VP S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> vVI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br /> N/A <br /> SUBSTANCE REMAINING IN NIAGALLONSINERT MATERIAL' ❑YES r.RrNO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY JUR lvD TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED&SIGNATURE) DATE <br /> RANTDALL BAAKE @ ROBERT F: 7/24/90 <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> 16 100 <br /> CURRENT LOCAL AGENCY FACILITY ID#, APPROVED BY NAME / ') PHONE N WITH AREA CODE <br /> PERMIT NU BER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGEAMT. FEE CODE RECEIPT N BY: <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMP iD BY A FACILITY/SITE APPLICATION, FORM `A',UNL .:CURRENT FORMA' HAS BEEN FILED <br /> nwrw oOn/`LCCWtl CnDV <br />
The URL can be used to link to this page
Your browser does not support the video tag.