My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4747
>
2300 - Underground Storage Tank Program
>
PR0232482
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2024 2:38:22 PM
Creation date
11/7/2018 10:23:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232482
PE
2361
FACILITY_ID
FA0003719
FACILITY_NAME
WEST LANE CHEVRON
STREET_NUMBER
4747
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10437010
CURRENT_STATUS
01
SITE_LOCATION
4747 WEST LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WEST\4747\PR0232482\BILLING 1990-2003.PDF
QuestysFileName
BILLING 1990-2003
QuestysRecordDate
1/23/2018 4:55:33 PM
QuestysRecordID
3768664
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IFIED PROGRAM CONSOLIDATED F <br /> TANKS <br /> UNDERGROUND STORAGE TANKS TANK PAGE 1 <br /> (two pages per tank) <br /> Page 1 of 6 <br /> TYPE OF ACTION ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ® 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check.dem only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for local use only) (Spocifyreason-forlocalaseonly) ❑ 8 TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 FACILITY ID: O O O O O 0 0 0 0 0 0 <br /> Chevron Station#200764 <br /> LOCATION WITHIN SITE(optional) 431 <br /> 4747 West Lane, Stockton CA 95210 <br /> I.TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes ® No 434 <br /> 1 OWENS CORNING If"Yes",complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY M GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 9/28/90 12,000 0 <br /> ADDITIONAL DESCRIPTION(For local we only) 438 <br /> IL TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ®I. MOTOR VEHICLE FUEL ®Ia. REGULAR UNLEADED ❑2. LEADED [IS. JET FUEL <br /> (Ifmarked complete Petroleum Type) ❑lb. PREMIUM UNLEADED <br /> ❑3. DIESEL ❑6. AVIATION FUEL <br /> ❑2. NON-FUEL PETROLEUM ❑lc. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER <br /> [13. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory pose) 441 CAS#(from He amicus Materials inventory page) 442 <br /> ❑4. HAZARDOUS WASTE <br /> pncmd.Used on) REGULAR UNLEADED 800-61-9 <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1. SINGLE WALL ❑3. SINGLE WALL WITH [15. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> 02. DOUBLE WALL ❑4. SINGLE WALL IN VAULT [199. OTHER_ <br /> TANK MATERIAL-primary tank ❑1. BARE STEEL ®3. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95. UNKNOWN 444 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE W/100%METHANOL ❑99.OTHER <br /> _ <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary look 01. BARE STEEL ®3. FIBERGLASS/PLASTIC 05. CONCRETE 095. UNKNOWN 445 <br /> (Check one item only) ❑2. STAINLESS STEEL [14. STEEL CLAD W/FTHERGLASS [18. FRP COMPATIBLE W/100%METHANOL ❑99.OTHER_ <br /> REINFORCED PLASTIC(FRP) ❑10.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING [15.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ®6 UNLINED ❑99 OTHER <br /> (Check one hem only) (For IoW use only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC 19 3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 448 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (Forlecalmemly) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) ®1 SPILL CONTAINMENT ®3 FILL TUBE SHUT OFF VALVE <br /> 1990 ®1 ALARM OPW 61-SO-4 <br /> ®2 DROP TUBE 1998 OP W 61-SO-4 ❑2 BALL FLOAT _ ❑4 EXEMPT <br /> ®3 STRIKER PLATE Tank Mf <br /> IV.TANK LEAK DETECTION(A description ofthe monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one dem only) <br /> ❑1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑ 1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR) BIENNIAL TANK TESTING [:199 OTHER _ <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons ❑Yes E] No <br /> UPCF(1/99 revised) 173 Formerly SWRCB Form <br />
The URL can be used to link to this page
Your browser does not support the video tag.