My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4747
>
2300 - Underground Storage Tank Program
>
PR0232482
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2024 2:38:22 PM
Creation date
11/7/2018 10:23:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232482
PE
2361
FACILITY_ID
FA0003719
FACILITY_NAME
WEST LANE CHEVRON
STREET_NUMBER
4747
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10437010
CURRENT_STATUS
01
SITE_LOCATION
4747 WEST LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WEST\4747\PR0232482\BILLING 1990-2003.PDF
QuestysFileName
BILLING 1990-2003
QuestysRecordDate
1/23/2018 4:55:33 PM
QuestysRecordID
3768664
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WNWIED PROGRAM CONSOLIDATED F <br /> 7(twopages <br /> TAItank) <br /> UNDERGROUND STORAGE TANKS TANK PAGE 1 pe <br /> TYPE OF ACTION ❑I NEW SITE PERMIT ❑ 4 AMENDED PERMIT Page 3 of6 <br /> (Check one hem only) ® 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWALPERMIT (Specilyreason-furloalueerty) (S reaon- <br /> PecifY for hswl ueonly) ❑ 8 TANK REMOVED Uo <br /> BUSINESS NAME(Same u FACILITY NAME or DBA-Doing Business As) <br /> Chevron Station#200764 3 FACILITY ID: O O 0 0 0 0 0 0 0 0 0 <br /> LOCATION WITHIN SITE(OphonaQ <br /> 4747 West Lane,Stockton CA 95210 431 <br /> t.TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 4Jz TANK MANUFACTURER 433 <br /> .)t oayooj COMPARTMENTALIZED TANK Yes No 434 <br /> 'l O WENS CORNING If"Yes",complete one page for each companmat. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY M GALLONS m6 <br /> 9/28/90 NUMBER OF COMPARTMENTS <br /> 12,000 417 <br /> ADDITIONAL DESCRIPTION <br /> (For bat uu only) . <br /> 438 <br /> 1I.TANK CONTENTS <br /> TANK USE439 PETROLEUMTYPE <br /> 10 1. MOTOR VEHICLE FUEL, ❑la. REGULAR UNLEADED ado <br /> (Ifmarked complete Peuoleum Type) ❑2. LEADED ❑5. JET FUEL <br /> ❑Ib. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION FUEL <br /> ❑2. NON-FUEL PETROLEUM ®lc- MIDGRADE UNLEADED ❑4. GASOHOL <br /> ❑3. CHEMICAL PRODUCT ❑99. <br /> COMMON NAME (6om Fluardous Materials Invemory CAS#( u <br /> ❑4. HAZARDOUS WASTE page) 441 CAS# from Hatdous Materub Inventory page) 443 <br /> pmludes Used Oil) MID-GRADE UNLEADED <br /> ❑95.UNKNOWN - 800-61-9 <br /> III. TANK CONSTRUCTION <br /> 7YPEOFTANK ❑1. SINGLE WALL 3. SINGLE WALL WITH <br /> S. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one hem only) EXTERIOR MEMBRANE LINER <br /> 095. UNKNOWN <br /> 02. DOUBLE WALL ❑4. SINGLE WALL IN VAULT ❑99. OTHER_ <br /> TANK MATERIAL_primary tank ❑ I. BARE STEEL ®3. FIBERGLASS/PLASTIC <br /> ❑5. CONCRETE ❑95. UNKNOWN 4t <br /> (Check one item only) ❑2. STAINLESS STEEL [14. STEEL CLAD W/FIBERGLASS <br /> [18. FRP COMPATIBLE W/100%METHANOL ❑99 OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL_aecondvy unk ❑1. BARE STEEL 3. F®ERGLASS/PLASTIC ❑5. CONCRETE <br /> 095. UNKNOWN 445 <br /> (Check onehem only) [12. STAINLESS STEEL <br /> ❑4. STEEL CLAD W/FIBERGLASS ❑S. FRP COMPATIBLE W/100%METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑ I.RUBBER LINED 3.EPDXY LINING ❑5.GLASS LIN 95.UNKNOWN 446 <br /> DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING 6 <br /> (Check one item only) ® UNLINED ❑99 OTHER <br /> OTHER CORROSION <br /> (For loul use only) <br /> ❑ 1 MANUFACTURED CATHODIC ®3 FIBERGLASS REINFORCED PLASTIC448 <br /> ❑95 UNKNOWN 44e <br /> PROTECTION IF APPLICABLE PROTECTION ❑4 IMPRESSED CURRENT <br /> (Check one hem only) ❑2 SACRIFICIAL ANODE ❑99 OTHER <br /> SPILL AND OVERFILL YEAR INSTALLED 45a (For local meonly) <br /> TYPE(bwl use only) 45I OVERFILL PROTECTION EQUIPMENT:YEAR INS <br /> (Check all that apply) TALLED 453 <br /> ®1 SPILL CONTAINMENT 19900 3 FILL TUBE SHUT OFF VALVE <br /> ®2 DROP TUBE ®I ALARM OP W 6I-SO-4 <br /> 1998 OP W 61-SO-4 ❑2 BALL FLOAT_ ❑4 EXEMPT <br /> ®3 STRIKER PLATE Tank Mf _ <br /> IV.TANK LEAK DETECTION(A description of the monitoring program.lull be submitted a the leml ager y.) <br /> IF SINGLE WALL TANK(Check all that apply) 451 IF DOUBLE WgLI TANK OR TANK WITH BLADDER 454 <br /> (Cheek one hem only) <br /> 111 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(M TG) 111 VISUAL(SINGLE WALL M VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR) BIENNIAL TANK TESTING 0 9 OTHER _ <br /> IV.TANK'CLOSURE -- <br /> /PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/4O/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons ❑Yes ❑ No <br /> I I PCF!1/99 revised) 175 <br />
The URL can be used to link to this page
Your browser does not support the video tag.