My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4747
>
2300 - Underground Storage Tank Program
>
PR0232482
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2024 2:38:22 PM
Creation date
11/7/2018 10:23:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232482
PE
2361
FACILITY_ID
FA0003719
FACILITY_NAME
WEST LANE CHEVRON
STREET_NUMBER
4747
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10437010
CURRENT_STATUS
01
SITE_LOCATION
4747 WEST LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WEST\4747\PR0232482\BILLING 1990-2003.PDF
QuestysFileName
BILLING 1990-2003
QuestysRecordDate
1/23/2018 4:55:33 PM
QuestysRecordID
3768664
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA • .•" �.� <br /> ti <br /> STATE WATER RESOURCES CONTROL BOARD 3 <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> ( <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br /> ONE REM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: Cka-, 5r SS O D7 6 <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A OWNER'S TANK 1.0.♦ 7j B. MANUFACTURED BY: G LA. &- QYyY�2 <br /> C. DATE INSTALLED(MO/DAY/YEAR) l D. TANK CAPACITY IN GALLONS: 0 <br /> II,TANK CONTENTS IFA-1 IS MARKED.COMPLETE ITEM C. <br /> A �1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C. 1S REGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AVIATIONGAS <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY 1 PRODUCT 1b PREMIUM UNLEADED ❑ 4 JET FUEL ❑ 7 METHANOL <br /> ❑ 11 MIOGRADE UNLEADED ❑ 5 JET FUEL ❑ 8 M85 <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER(DESCRIBE IN DEMD.BELONG <br /> D. IF(A1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.N <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.8,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF Idl 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 8 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (PHRMryTwk) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER UNED ❑ 2 ALKYD LINING ❑ 3 EPDXY UNING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING 8 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH IDD% METHANOL? YES— NO_ <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION91 NONE 95 UNKNOWN 99 OTHER <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ ❑ ❑ <br /> SPILL CONTAINMENT IN ALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEA <br /> E.SPILL AND OVERFILL,BLC, DROP TUBE YES NO. STRIKER PLATE YES�NO DISPENSER CONTAINMER)N YES NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A/6)_2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLEPIPING A U 99 OTHER <br /> B. CONSTRUCTION A U I SINGLE WALL A 2 DOUBLE WALL A U 3 UNED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> - <br /> 1 MECRWCAL UNE SAK2 LINE TNHI % 3 CONIINUWS INIERSTIRAL 4 EIECMOMC UNE 5 AVICLMTC PUW ❑ 99 OTTER <br /> D. LEAK DETECTION ❑ dam ❑ IEmM1 WMTWING UmOE1ECT011 $XUfD0V4/ <br /> V.TANK LEAK DETECTION �/ <br /> ❑I 1 VISUAL CHECK IyJ 2 RECONCILIATIONNUAL INVENTORY ❑ 3 MAON�ITORING ZE 4 GAUGING AUTOMATIC TANK ❑ 5 MONITORINGGROUNDWATER ❑8 ANNUAL TESTINGTANK <br /> `�-� 7 MONITORING INTERSTITIAL ❑ 8 SIR ❑ B WEEKLY <br /> TANK GAUGING ❑ 10 TESTING TANK ❑ 95 UNKNOWN ❑99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PUCE) <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO❑ <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> hrlIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO HE BEST OF MY KNOWLEDGE,IS TRU AN CORRECT <br /> -XAMK-9WNER'S NAME DATE <br /> LPRLNsly_RET O <br /> LOCAL AGENCY USE ONLY THE STATE I .N BER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUN k JURISDICTION M FACILITY# TANK N <br /> STATE 01 m F-T-F-= <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPUON-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THIVRGROUND STORAGE TANK REGULATIONS <br /> FORM B (EBS) <br />
The URL can be used to link to this page
Your browser does not support the video tag.