SAN J O A Q U I N Environmental Health Department <br /> - -- C 0U N J_ Y - tic <br /> hlTollo 'I <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name : Facility Address : Date : <br /> EASY FUEL 2420 E EIGHT MILE RD , STOCKTON November 06 , 2018 <br /> Other Violations <br /> 4050 See below Unlisted Abandonment/illegal Disposal/Unauthorized Treatment violation ❑ V ❑ R ❑ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I , CLASS II , or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 302 CFR 112 . 5 ( b ) Failed to review Plan once every five years and/or implement any resulting amendments . <br /> The Spill Prevention , Control , and Countermeasure ( SPCC ) Plan was last reviewed on November of 2012 . A review <br /> and evaluation of the SPCC Plan must be conducted at least once every 5 years. As a result of this review and <br /> evaluation , the SPCC Plan must be amended within 6 months of review, and recertified by a Professional Engineer <br /> if any technical amendments were made . Immediately conduct a review of the facility SPCC Plan and make any <br /> necessary amendments . <br /> This is a Class II violation . <br /> 706 CFR 112 . 8 ( c) (2 ) Failed to provide and maintain adequate secondary containment . <br /> The two 10 , 000 gallon tanks were observed with insufficient secondary containment. Two small diameter holes was <br /> observed at the base of the secondary containment wall , allowing liquid from inside the containment area to drain to <br /> the outside of the containment area . All bulk storage tanks must be provided with a secondary means of <br /> containment for the entire capacity of the tank and sufficient freeboard to contain precipitation . Immediately provide <br /> sufficient secondary containment for this and all other tanks at this facility . <br /> This is a Class II violation. <br /> 710 CFR 112 . 8 ( c) (6 ) Plan failed to adequately discuss procedures to test or inspect each container for integrity . <br /> The SPCC plan does not specify an industry standard for the inspections and testing of the tanks . An SP-001 <br /> inspection is mentioned in the SPCC plan but only after signs of leakage are discovered . Each aboveground <br /> container shall be tested and inspected for integrity on a regular schedule and whenever repairs are made . The <br /> qualifications of personnel performing tests and inspections , frequency and type of testing and inspections that take <br /> into account container size , configuration , and design shall be determined in accordance with industry standards . <br /> Examples of these integrity tests include , but are not limited to : visual inspection , hydrostatic testing , radiographic <br /> testing , ultrasonic testing , acoustic emissions testing , or other systems of non -destructive testing . Comparison <br /> records and other records of inspections and tests must be maintained on site . Specify an industry standard that <br /> will be used for the tanks , or provide equivalence as allowed by CFR 112 . 7 ( a) (2 ) . <br /> This is a Class II violation. <br /> Overall Inspection Comments : <br /> This is an amended version of the report issued on 11 /06/2018 . The report was amended on 11 /07/2018 and <br /> supersedes any previous versions . <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation , and any supporting <br /> paperwork within 30 day of receipt of this report . <br /> Starting September 1 , 2018 , all in - office CERS help will be provided at EHD hourly rate ($ 152 ) . To schedule an <br /> appointment , please call (209 ) 468 -3420 . <br /> FA0020345 PR0536578 SCO01 11 /06/2018 <br /> EHD 28-01 Rev. 09/27/2018 Page 4 of 5 Aboveground Petroleum Storage Act OR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468 -3420 F 209 464 -0138 1 www . sjcehd . com <br />