My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHT MILE
>
2420
>
2800 - Aboveground Petroleum Storage Program
>
PR0536578
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2019 11:19:07 AM
Creation date
11/7/2018 10:52:30 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0536578
PE
2832
FACILITY_ID
FA0020345
FACILITY_NAME
EASY FUEL
STREET_NUMBER
2420
Direction
E
STREET_NAME
EIGHT MILE
STREET_TYPE
RD
City
STOCKTON
Zip
95210
APN
12002014
CURRENT_STATUS
01
SITE_LOCATION
2420 E EIGHT MILE RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: [November <br /> ate: <br /> EASY FUEL 2420 E EIGHT MILE RD, STOCKTON 06, 2018 <br /> Other Violations <br /> 4050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 302 CFR 112.5(b) Failed to review Plan once every five years and/or implement any resulting amendments. <br /> The Spill Prevention, Control, and Countermeasure(SPCC)Plan was last reviewed on November 2102. A review <br /> and evaluation of the SPCC Plan must be conducted at least once every 5 years. As a result of this review and <br /> evaluation,the SPCC Plan must be amended within 6 months of review, and recertified by a Professional Engineer <br /> if any technical amendments were made. Immediately conduct a review of the facility SPCC Plan and make any <br /> necessary amendments. <br /> This is a Class II violation. <br /> 706 CFR 112.8(c)(2)Failed to provide and maintain adequate secondary containment. <br /> The two 10,000 gallon tanks were observed with insufficient secondary containment. Two small diameter holes was <br /> observed at the base of the secondary containment wall, allowing liquid from inside the containment area to drain to <br /> the outside of the containment area. All bulk storage tanks must be provided with a secondary means of <br /> containment for the entire capacity of the tank and sufficient freeboard to contain precipitation. Immediately provide <br /> sufficient secondary containment for this and all other tanks at this facility. <br /> This is a Class II violation. <br /> 710 CFR 112.8(c)(6)Plan failed to adequately discuss procedures to test or inspect each container for integrity. <br /> The SPCC plan does not specify an industry standard for the inspections and testing of the tanks.An SP-001 <br /> inspection is mentioned in the SPCC plan but only after signs of leakage are discovered. Each aboveground <br /> container shall be tested and inspected for integrity on a regular schedule and whenever repairs are made. The <br /> qualifications of personnel performing tests and inspections,frequency and type of testing and inspections that take <br /> into account container size, configuration, and design shall be determined in accordance with industry standards. <br /> Examples of these integrity tests include, but are not limited to:visual inspection, hydrostatic testing, radiographic <br /> testing, ultrasonic testing, acoustic emissions testing, or other systems of non-destructive testing. Comparison <br /> records and other records of inspections and tests must be maintained on site. Specify an industry standard that <br /> will be used for the tanks, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by December 6, 2018 . <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209)468-3420. <br /> FA0020345 PR0536578 SCO01 11/06/2018 <br /> EHD 28-01 Rev.09/27/2018 Page 4 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.