REMOVAL_1998
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
2211
>
2300 - Underground Storage Tank Program
>
PR0231304
>
REMOVAL_1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 3:04:16 PM
Creation date
11/7/2018 11:25:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1998
RECORD_ID
PR0231304
PE
2332
FACILITY_ID
FA0003694
FACILITY_NAME
RIVER CITY PETROLEUM CARDLOCK
STREET_NUMBER
2211
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11707050
CURRENT_STATUS
02
SITE_LOCATION
2211 N WILSON WAY
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\W\WILSON\2211\PR0231304\REMOVAL 1998.PDF
QuestysFileName
REMOVAL 1998
QuestysRecordDate
8/10/2017 10:02:01 PM
QuestysRecordID
3569932
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> r <br /> II. GENERAL INFORMATION: <br /> 1, Obtain an EPA Site Number from the Department of Toxic Substances Control (800) 61-TOXIC for <br /> temporary hazardous waste removal activities associated with underground storage tank{UST) removals. <br /> 2. Disposal Information: Public Health Services Underground Storage Tank Disposition Tracking Record <br /> (UST Tracking Record, page 10) shall accompany each tank removed from site. Tank(s) will be issued <br /> an identification number which PHS-EHD's representative will note on the UST Tracking Record. <br /> Contractor will affix same identification number onto tarok end using fluorescent spray paint. Contaminated <br /> tanks and/or piping are to be transported under Hazardous Waste Manifest by a state registered hazardous <br /> waste hauler. <br /> 3. Contractor to Provide: Combustible/Flammable gas detector(to verify the Lower Explosive Limit(LEL) <br /> atmosphere and oxygen level of tank prior to lifting from excavation), adequate number(s) and appropriate <br /> type(s) of fire extinguisher(s), barriers to secure the area as necessary to minimize traffic and pedestrian <br /> cation numbers. It shall <br /> the project <br /> interference, and fluorescent spray ance with all health&aint to affix tank isafetyiregulat ons and requirements, which shall <br /> manager's responsibility far comp <br /> be strictly adhered to at all times during the course of the closure activities. <br /> 4 The PHS-EHD permit shall be on site during tank excavation and removal. <br /> 5. Any changes in this document shall be approved by PHS-EHD prior to initiating work. <br /> 6. Closure-In-Place: if Closure-in-Place is the suggested method of abandonment, complete form <br /> EH 23 039 and submit written approval from the local Fire Department, <br /> 7 Temporary Closure: If Temporary Closure is the suggested method of abandonment, complete <br /> and submit this form and a written approval from the local Fire Department. <br /> g, The following documentation shall be submitted within 30 days of the tank removal <br /> date: <br /> a) Analytical results, mailed directly from laboratory to PHS-EHD, including a chain of custody and <br /> quality assurance and quality control (QA & QC). <br /> b) UST Tracking Record Sheet(s) and/or Tank Hazardous Waste Manifest(s). <br /> C) Hazardous Waste Manifests for piping, rinsate, residual fuel, or waste oil receipt. <br /> d) Submit the backfill excavatioa certificate as required by San Joaquin County and the incorporated <br /> City Building Departments. This report will be referred to the appropriate agency for their <br /> review. <br /> A site which has had UST(s) removed, shall not be considered for final closure until the above items <br /> are submitted for review. <br /> III. SITE MITIGATION: <br /> 1. In the event contamination is observed, confirmed or suspected as a result of a leaking UST system it is <br /> the responsibility of the owner or operator to submit a workplan to PHS-EHD Site Mitigation Unit prior <br /> to initiating any assessment or remediation activities. To minimize delays, a Corrective Action Plan may <br /> be submitted concurrent with tank closure or installation plans. Address one copy of the Corrective Action <br /> Plan to the Site Mitigation Unit for review. For further assistance contact the Site Mitigation Unit at (209) <br /> 468-3450. <br /> EH 23 046 (Revised 9/11/96) Page 2 <br />