INSTALL_PLAN 2000
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1234
>
2300 - Underground Storage Tank Program
>
PR0516248
>
INSTALL_PLAN 2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2024 2:38:26 PM
Creation date
11/7/2018 11:56:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
PLAN 2000
RECORD_ID
PR0516248
PE
2361
FACILITY_ID
FA0012532
FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
01
SITE_LOCATION
1234 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1234\PR0516248\INSTALL PLAN 2000.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 3/4" CONDUIT FOR PUMP POWER 1'" CONDUIT TO INTRINSICALLY <br /> v TO ELECT. PANEL - i PER TANK <br /> FILL TUBE SAFE GUTTER AT MONITOR 54 42" MANHOLE 3/4" EXPLOSION <br /> CONTROL PANEL (, PER TANK) PEA GRAVEL PROOF 45' ELBOW <br /> o -' -- 2" BLACK IRON NIPPLE 2% 1'-0"x 1'-0"" STYROFOAM <br /> o <br /> v 5" 2" BALL VALVE ^ 2" ELL <br /> MAX.. ` <br /> ."L / EXPLOSION PROOF <br /> \ JUNCTION BOX a <br /> / a <br /> 3" PVC PIPE OPEN AT BOTTOM. Z x <br /> TOP OF FIBERGLASS OVERLAY / f \ \ g < <br /> STEEL PLATE `� l>< FILTERGSEPARATOR 57 N O <br /> PLLD N CONTAINMENT SUMP REDUCER, <br /> S2A \� p — 2" BLACK IRON NIPPLE 51 TURBINE PUMP FIBERGLASS REDUCER ON THE OUTSIDE <br /> TO ENSURE WATER TIGHTNESS i0 <br /> 2" NIPPLE PIPE CAP WITH HOLE <br /> PLLD Z" BLACK IRON ELL 58 2" BALL VALVE I FOR CONTROL WIRES <br /> (FULL PORT) JUNCTION BOX <br /> O9 CONTAINMENT SUMP ^1� /^ (EXPLOSION PROOF) <br /> --TUMP <br /> UBE 15 (FOR HIGH WATER TABLE) \ 1/2" BALL VALVE 111 <br /> 1/2" BRAIDED STAINLESS STEEL 1 <br /> >/ TUBING DRAIN LINE 3/4" CONDUIT TO ELECT. I <br /> \ \\ 1/2" BLACK IRON STREET ELL PANEL (PUMP POWER) SEAL OFF <br /> 51 TURBINE PUMP 2"x24" FLEXIBLE CONNECTOR INTRI�NDUIT SIICALLYOSAFE <br /> MALE BY MALE SWIVEL 7q GUTTER AT MONITOR <br /> 02" SCH. 40 FRP. CONTROL PANEL <br /> V 3" PVC PIPE OPEN AT <br /> 56 2" BALL VALVE BELL x MALE I BOTTOM, <br /> THREADED ADAPTER I <br /> 2" BLACK IRON 90' ELL 2" SCH. 40 FRP, 0 0 PENETRATION BOOT THREAD DE ADAPTORS <br /> 45' ELBOW (FOR CONDUIT) 3"x2" BOOT WITH <br /> STEEL PLATETEST PORT 73 <br /> 3"x 2" BOOT WITH TEST PORT 73 I <br /> PENETRATION BOOT ROLL BACK BOOT <br /> DET B 3" FRP 21 9 AFTER TESTING <br /> SWIVLE 2"x34" MxF FLEXIBLE <br /> PLAN 2" FRP 20 <br /> CONNECTOR FIBERGLASS CONTAINMENT SUMP TO TANK <br /> 1/4" BRAIDED STAINLESS STEEL 1/2" BALL VALVE NOTE: DO COLLAR INSIDE AND GOT TO INSURE <br /> 1 NOT EXCEED <br /> TUBING VENT LINE MANUFACTURERS SPECIFIED I WATER TIGHTNESS <br /> 0 o w FOR DETAIL OF TANK SLAB O1/2" BLACK IRON NIPPLE BEND RADIUS ql TIP21 <br /> FRP PRODUCT 20 <br /> pzo wp SEE SHEET F-7.T 54 " MANHOLE P <br /> 42 E IN 3" FRP <br /> 51 TURBINE PUMP 1/2" TO 1/4" REDUCING STREET ELL SECONDARY CONT. <br /> z � i z0 2"x 1'-0"x V-0" STYROFOAM BLACK IRON PIPE <br /> PEA GRAVEL <br /> a in Su < BACKFILL q. 4" N.P.T. LIQUID SENSOR 91 <br /> 4" N.P.T. PLUGGED <br /> HE x <br /> ELEVATION <br /> NEW TANK DIMENSION g TURBINE WITHOUT FILTER <br /> o z <br /> 0 I CHART EXPLOSION PROOF - <br /> I i TANK TANK JUNCTION BOX .N O <br /> n SIZE LENGTH3/4" EXPLOSION ca CONTAINMENT SUMP REDUCER, <br /> —_ 12.,000 GAL 24'-0-1/4" FIBERGLASS REDUCER ON THE OUTSIDE <br /> PROOF FF ELBOW <br /> I TO ENSURE WATER TIGHTNESS 70 <br /> / 15,000 GAL 29'-5-3/4" SEAL OFF <br /> O I � � \ — 2" BALL VALVE 2 I/2"FROM TOP Of <br /> M 5 120,000 GAL. 37'-8-3/4" 1� 2"x24" FLEXIBLE SPILL BUCKET TO TO <br /> 1 / CONNECTOR MALE BY 2"' BLACK IRON 90' ELL D <br /> d OF STEEL SLEEVE <br /> G z I4 ALUM FILL TUBE W POSITIVE SHIT OFF 45 - 4 <br /> R / �✓ MONITORIIPROBE TO LOW I I \ MALE SWIVEL <br /> NOTE: <br /> END OF (TANK. 87 VERIFY TANK LENGTH 3/4" CONDUIT TI O o o <br /> 7 7,O } I I l I I WITH MANUFACTURE. BOXILL SUMP JUNCTION j .. FUEL-GUARD L, Op - d GRADE 1" CONDUIT TO O - a d d <br /> 1 I OBTAIN EXISTING TANK FILTER SEPARATOR 57 <br /> INTRINSICALLY SAFE <br /> \ 1 I I I / LENGTH WITH GUTTER AT MONITOR 1/2" BLACK IRON ELL U 4 <br /> Imo` SLOPE TANK i" N 10' MANUFACTURE. CONTROL PANEL I O <br /> / 1 DOWN TOWAFkDS FILL END / IyHy�� \ / (1 PER TANK) 2" BALL VALVE 56 <br /> / 1 3/4" CONDUIT FOR <br /> 14 <br /> TANK BUNG WITH 1 I ` / PUMP POWER TO /2" PORT F <br /> ELECT. PANEL <br /> _ —1 PER TANK I .. FIBERGLASS CONTAINMENT SUMP TO TANK NOTES' V <br /> 1 COLLAR INSIDE AND OUT TO INSURE WATER TIGHTNESS <br /> '��_�� 91 LIQUID SENSOR--�— — ENSIONS SHALL BE <br /> 1/2" BRAIDED STAINLESS STEEL 1 HELD TRUE ALL ATO INSURE S AND MWATER TIGHT SEALS. <br /> IIz �oT�_ SEE DET. A ABOVE I� -III T TUBING DRAIN LINE <br /> _ gSEE DET. B ABOVE .III—III=1 1— _._ <br /> STEEL PLATES UNDER EACH FILTER MOUNTING <br /> 2'-0" OPENING BY TANK MANUFACTURER 2"-0" 3" PVC PIPE OPEN AT ELEVATION BRACKET FOR 4" PIPE59. <br /> MIN. SEE TANK DIMENSION CHART MIN. BOTTOM. ATTACH TO STEEL RISEiI TURBINE W FILTER <br /> WITH UNISTRUT FOR SUPPORT R <br /> 8 10' DIA. 15,000 GAL. FIBERGLASS TANK AND EXCAVATION SECTION TURBINE 1 SPILL BUCKET DETAIL <br /> INSTALLATION INSTRUCTIONS: JUNCTION BOX (EXPLOSION PROOF) <br /> A PULL STRING MAY BE IN THE TANK. INSTALL A COLOR CODED <br /> PRODUCT COLLAR 33 SEAL OFF <br /> NEW PULL STRING IF THE STRING MISSING, LOST <br /> OR BROKEN. THE PULL STRING IS NOT A TANK 4" TOP SEAL ADAPTOR VAPOR RECOVERY ADAPTOR TEM PROBE MOUNTING FITTING 86 <br /> MANUFACTURER WARRANTY ITEM.BOTTOM <br /> ALL THE AND CAP 29 30 AND CAP 4" CAP ON RISER TANK PLUG - TORQUE TO <br /> INTERSTITIAL MONITOR AT THE BOTTOM CENTERLINE <br /> OF THE PRP TANK. INSERT FISH TAPE THROUGH THE 18" 37 300 FPL LBS. PRIOR TO ISOLATION CAP <br /> ANNULAR SPACE, TAG BOTH THE PULL STRING TO THE 300 F INSTALLING ISOLATION CAP TANK FITTING <br /> PROBE SIGNAL CABLE AT 12.5 FT. PLUS THE BURIAL 2 1/2'" FROM 2 1/2" FROM <br /> DEPTH. ATTACH THE PULL STRING TO THE PROBE AND - TOP OF SPILL - - TOP OF SPILL <br /> m TO THE FISH TAPE AND PULL THE PROBE INTO TANK. JUNCTION BOX ° c c ° BUCKET TO __ a BUCKET TO c ° G.E. SCS 1202 COMPRESSION RING <br /> WHEN THE TAGS ON THE SIGNAL CABLE AND THE PULL - n o p. d 4 ° ° TOP OF STEEL p �n ° ° TOP OF STEEL ° v ° SILICONE SEALEANT <br /> E STRING MATCH, THE PROBE IS AT THE BOTTOM ° SLEEVE p _d ° ° SLEEVE a ° p d ° ° ° ° ISOLATION <br /> CENTERLINE OF THE TANK. THE PULL STRING IS TO 18'" MANHOLE W/ °p a .a 4 °p p. a d �p o, 'O d <br /> N REMAIN IN PLACE FOR FUTURE ACCESSIBILITY. SECURED LID 37 TANK FITTING BASE <br /> — <br /> C WATER TIGHT SPILL BUCKET 38 SPILL BUCKET t39 BASE <br /> ° MONITOR PLUG89 <br /> F y <br /> 4"-150# COUPLING <br /> UNUSED FITTING <br /> MONITOR TAG & 4"-150# COUPLING --- <br /> o � I ° <br /> o <br /> HOLDER <br /> u ° <br /> 3/4" CONDUIT TO TURBINE SUMP <br /> 4" SCH. RISER <br /> � II i" MAXIMUM PRIMED AND <br /> WRAPPED <br /> WRAPPED JUNCTION BOX. <br /> N <br /> a 4" SCH. 40 NIPPLE -- <br /> (GALVANIZED) <br /> 4" ALUMINUM FILL TUBE <br /> 0 4"-300# COUPLING 2 TANK FITTING ISOLATION DETAIL <br /> (GALVANIZED) , , , 3/4" CONDUIT FROM <br /> E _ _ ANNULAR SPACE MONITOR NO SCALE <br /> 0 C SCH. 40 GALVANIZED RISER 2"x 18" FLEX CONNECTOR 4" SCH. 40 GALVANIZED STEEL RISER <br /> n PRIMED AND WRAPPED MALE SWIVEL/FEMALE PRIMED A, WRAPPED <br /> d II 3/4" m CONDUIT WITH CONTAINMENT BOOT Chevron U.S.A. Inc. ("Chevron") owns the copyright rights to the design of the herein described fueling <br /> I TO FILL SUMP J—BOX FLEX CONNECTOR system as embodied in any tangible or electronic medium of expression includingall building <br /> o PHASE II VAPOR RETURN ' designs, architectural <br /> a TANK FITTING WITH CONTAINMENT BOOT 1 1. 1' N 9 plcns and drawings. The copyrighted material includes the overall form as well as <br /> the arrangement and composition of spaces and elements in the design, but does not include individual C <br /> of �" standard features. Anyone who wishes to copy, distribute or sell this drawing or any derivative works Q <br /> ° 4" SCH. 40 GALVANIZED VENT � cJ7.. �� based hereon must have the prior written consent of Chevron, except for copies made for the sole <br /> ME purpose of preparing construction drawings for Chevron branded facilities and all such copies shall be < <br /> PIPE RISERreturned to Chevron upon request. <br /> ©1998 Chevron U.S.A. Inc. All rights reserved. a <br /> ox <br /> m PRIMED & WRAPPED "i ` <br /> E <br /> The drawings, calculations, and any specific reference to equipment, materials or components, U <br /> v 4" SCH. 40 GALVANIZED ( if included herein, are generic and not designed for site specific applications. Chevron does not warrant F <br /> '? II PIPE RISER FX TRACTQR FITTING 42 or guaranty the occaracy, completeness, merchontabilty, intended use or applicability of such drawings, <br /> PRIMED & WRAPPED I calculations, and any referenced equipment, materials or components, to the requirements or < <br /> needs of your site or local area. Consult a registered architect or professional engineer to determine <br /> z II POSITIVE SHUT OFF DEVICE: any site specific design, applicability, accessibility, building code, municipal requirements and any and <br /> a TANK FITTING / INSTAI L AT 95% OF TANK all applicable federal, state and local statutes, rules and regulations which may affect your site. 2 <br /> o / CAPACITY 45 Chevron does not provide these services. <br /> o <br /> ui <br /> TAMC SECTION, TURBID AND ALL DETAILS <br /> n PRODUCT FLOAT a, Chevron <br /> o, <br /> %a WATER FLOAT <br /> m m SIDE VIEW AT TANK BOTTOM BBQ 20'9767 <br /> y"' BOTTOM LOCKING NUT Marketing YOSEMITE AND SPRECKLES <br /> U N <br /> � U <br /> MANTECA, CA <br /> LL t WIRE INSTALLATION CABLE <br /> STEEL PLATE AT TANK BOTTOM Revisions <br /> SENSOR a7 — SCALE 1/4•4-0" DATE <br /> DR. CH. APP. <br /> 7 ANNULAR SPACE MONITOR 6 FILL DETAIL 5 VAPOR AND VENT 4' AUTOMATIC TANK GUAGE SHEET <br /> RHL JOB# Si 65.31 <br /> I - <br />
The URL can be used to link to this page
Your browser does not support the video tag.