Laserfiche WebLink
J 1 <br /> ONMED PROGRAM CONSOLIDATED 4PM Wql6 0� <br /> UNDERGROUND STORAGE TANK r <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION(One form per UST) <br /> TYKE OF ACTION (Check one item only. For an UST permanent closure or removal,complete only this section and Sections L R,RI,IV,and IX below) 030 <br /> [v7 1.NEW PERMIT ❑ 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 430a DATE EXISTING UST DISCOVERED: 90b <br /> L FACILITY INFORMATION <br /> FACILITY ID H(Agency Use Only) _ - 1 3 17 1319 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 <br /> Tower Mart#886 <br /> BUSINESS SITE ADDRESS 103 CTfY 109 <br /> 1434 W.Yosemite Ave. Mmteca CA <br /> II.TANK DESCRIPTION <br /> TANK IDH MG-886 632 TANK MANUFACTURER 433 T.q.NVONFIGURATION: THIS TANK IS 434 <br /> Modern Welding LTJ 1.A STAND-ALONE TANK <br /> / / SOS ❑2.ONE IN A COMPARTMENTED UNIT. <br /> Com late we pw for each com M in the umt. <br /> DATE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT 433 <br /> Jan 1991 10,000 Gal One 1 <br /> 11 M.TANK USE AND CONTENTS <br /> TANK USE la MOTOR VEHICLE FUELING ❑ lb.MARINA FUELING ❑ lc.AVIATION FUELING 439 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Ue Oil) ❑ 5.EMERGENCY GENERATOR FUEL(HSC§25281.5(c)1 <br /> ❑ 6.OTHER GENERA OR FUEL ❑ 95.UNKN ❑ 99.OTHER (Specify): 43% <br /> CONTENTS PETROLEUM: ,/L a.REGULAR UNLEADED lc.MIDGRADE UNLEADED ❑ lb.PREMIUM UNLEADED 440 <br /> ❑ 3.DIESEL ❑ S.JET FUEL ❑ &AVIATION GAS <br /> ❑ S.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM S 110. <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTIID2NON-PETROLEUMS 4Ob <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL 2.DOUBLE WALL ❑ 95.UNKNOWN 443 <br /> PRIMARY CONTAINMENT 1.BTEEL ❑ 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444 <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN [199.OTHER (specify): 441a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ❑3.FIBERGLASS 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 45 <br /> ❑ 90.NONE ❑ 95.UNKNOWN [199.OTHER(Speci : 415a <br /> OVERFILL PREVENTION 1.AUDIBLE&VISUAL ALARMS U 2.BALL FLOAT 3.FI.L TUBE SHUT-OFF VALVE 452_ <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑L SINGLE-WALLED 2.DOUBL&WALLED ❑99.onfER 169 <br /> SYSTEM TYPE V 1.PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION[23 CCR§263 s 3I 458 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ I0.RIGIDPLASTIC 664 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OITIBR(Specify): 464 <br /> SECONDARY CONTAINMENT ❑ 1.STEEL Er 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464 <br /> ❑ 90.NONE ❑ 5.UNKNOWN ❑ 99.OTHER(Specify): 464 <br /> PIPINGfTURBINE CONTAINMENT SUMP TYPE 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 464 <br /> VL VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT LLY 1.STEEL ❑ 4.FIBERGLASS Lj 10.RIGID PLASTIC 90.NONE 99.OTHER(Specify) 464 <br /> 44e1 <br /> VENT SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464f <br /> 464n <br /> VR PRIMARY CONTAINMENT 1.STEEL ❑ 4.FIBERGLASS 10.RIGID PLASTIC 90.NONE 99.OTHER(Specify) 4w a <br /> VR SECONDARY CONTAINMENT ❑ L STEEL 0 4.FIBERGLASS ❑ 10.RIGIDPLASTIC 0 90.NONE ❑ 99.OTHER(Specify) 464h <br /> O hl <br /> VENT PIPING TRANSITION SUMP TYPE ❑ 1.SINGLE WAIL 2.DOUBLE WAIL ❑ 90.NONE 164E <br /> RISER PRIMARY CONTAINMENT ❑ 1.STEEL 4.FIBERGLASS 10.RIGID PLASTIC ❑ 90.NONE 99.OTHER(Specify) 4644 <br /> 464'1 <br /> RISER SECONDARY CONTAINMENT 0 1.STEEL ❑ 4.FIBEI!qLASS ❑ 10.RIGID PLASTIC 0 90.NONE ❑ 99.OTHER(Specify) 464k <br /> 464kl <br /> FILL COMPONENTS INSTALLED ff 1.SPIN BUCKET Eir 3.STRIKER PLATEIROTTOM PROTECTOR ❑ 4.CONTAINMENT SUMP 451. <br /> VII.UNDER DISPENSER CONTAINMENT(UDC) <br /> CONSTRUCTION TYPE 1.MM DOUBLE DOUBLE WALL ❑ 3.NO DISPENSERS [190.NONE 469a <br /> CONSTRUCTION MATERIAL [11.STEEL ❑ 4.FIBERGLASS 10.RIGID PLASTIC ❑ 99.OTHER(Specify) <br /> 4696.c <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ❑ 6.ISOLATION as. <br /> DL APPLICANT SIGNATURE <br /> CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true,accurate, <br /> and in full compliance with legal requwments. <br /> APPLICANT SIGNATURE O DATE 3/3/08 °'0 <br /> APPLICANT NAME(print) Paul Chevalier 411. APPLICANT TITLE Maintenance Manager 472. <br /> UPCF UST-B-12 Rev.(12/2007) <br />