My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL TANK TOP UPGRADE PLAN 1997
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
INSTALL TANK TOP UPGRADE PLAN 1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:41:25 PM
Creation date
11/7/2018 12:06:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
TANK TOP UPGRADE PLAN 1997
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1700\PR0231454\TANK TOP UPGRADE PLAN 1997.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> A B C D E F <br /> - POWER FOR l i0 TANK MONITOR <br /> TANK MONITOR I CONTROL PANEL <br /> PANEL - ----� 1 TO BREAKER P2-2,4 <br /> TO CONTACTOR <br /> YI 1 J UNLEADED PUMP MOTOR <br /> TO SWITCHED NEUTRAL_�NEUTRAL M2 �G 20 VOLTS FOR DISPENSER LIGHTS mI �I } 0 Q' 0 QI 0 L <br /> BREAKER P3-1 (SEE NOTE 6) <br /> ---HOT CONTACTOR _t 012 AIW TO CONTACTOR EM4 CONTROL FUSE m I 2 3 m 5F"3t <br /> 3 CONT 3 NEUTRAL FOR DISPENSER LIGHTS ^6 AMP MAX." m 1 2 3 �4 m SWITCH � �] 3 1 <br /> lYYPJ (TYPJ <br /> P vm P3-14N m D pL m FUSIBLE TERMINAL m D m 1^ 0 K 0 0 I O M um <br /> m Q Q N m BLOCK m 0 Q m ewTw c� <br /> O TURBINE OPERATION LIGHTS <br /> p 1lEECDEDO <br /> j WH PL BK UNLEADED <br /> TO SWITCHED NEUTRAL NEUTRAL <br /> BREAKER P3-8 SU BREAKER ED F <br /> 4PST DISPENSER Y R B SUPER UNLEADED PUMP MOTOR <br /> -HOT (SEE NOTE 6) <br /> (SUWIPTCI Y R B ISOLATION y Y R B <br /> 1 ] il <br /> RRELAY 70 OTHERP 4 (YTP.) 4 DISPENSER CONTROL' O P2 WHP3-ION 15PENeE L ISOLATION RELAYI U SluTw40 A L 2. � U 5wrw T !. � 2. 5.crF °' c 141—H 13 SURGE SUPER <br /> POWER FOR DISPENSER CONTROLS u I--�II3 c FOR DISPENSER 3 / 4 pN�8q xueo• 1 SUPPRESSOR ® 0 PL UNLEADED <br /> TO SWITCHED NEUTRAL-NEUTRAL WIRING TYPICAL OF DISPENSER 1 / 2 p c z z r r <br /> BREAKER P3-12 zp DIESEL PUMP MOTOTo BREAKER P R <br /> —HOT L O P 7 i O (SEE NOTE 6) <br /> YY YY YY 1 ] 3 <br /> 1 ] 3 m3 >•�J DISPENSER mm >^ tree-rn-a-• L <br /> P IlA-1 TERMINAL (TYPJ o y� O P3 UA4 <br /> P3-4N m m m m m m E5A DA <br /> O H NNI234 DISPENSER #I <br /> "N" N 1234 DISPENSER '2 aures DIESEL <br /> m m m m m m TO BREAKER P346 O <br /> ENSER <br /> WIRING S�PICALRPGF2D DISPENSER X82 il 11 i�4�r1gc1 --""t FSM DISPENSER - �i w }I� - -"t FROM DISPENSER "' POWER FOR YANK MONITOR PL �IESEL <br /> III �L__y f FOR PUMPS a 1 L C _ _ J FpR PUMPS Irc TO PANEL P3-I8 NEUTRAL <br /> ( I I I I I I NEUTRAL FOR TANK MONITOR PUMP STARTER (TTP.) <br /> I I I L___ FOR DISPENSER I I L____. FOR DISPENSER <br /> 1 1 L------� LIGHTS I I I------'-� LIGHTS <br /> 11 _ II TO PANEL P3 ISOLATED GROUND <br /> 2 LL--_-_y} DISPENSER POWER B L --_ _-- DISPENSER POWER G GROUND FOR TANK MONITOR <br /> 2 <br /> TO SWITCHED NEUTRALNEUTRAL GENERAL NOTES FOR DISPENSER CONTROLS <br /> BREAKER P3-26 <br /> --�T 1. ALL DOTTED LINES REPRESENT FIELD WIRING BY CONTRACTOR <br /> I ] 3 TO BREAKER d� m m <br /> P3 28 9 2. THE DISPENSER CONTROL WIRING SHOWN ON THIS DRAWING Ig 1 R R R R R R R R I M M M M M M M <br /> P WH P3-28N m m m m FOR TWO DISPENSER CONTROL RELAY CIRCUITS. THIS WIRING m g m <br /> IS TYPICAL OP ALL DISPENSER RELAY CONTROL CIRCUITS. yy yy Y 33 <br /> O m m 3. THE DISPENSER TERMINAL STRIP FIELD WIRING SHOU.N ON THIS m1 N mIIGII <br /> Y DRAWING IS FOR TWO DISPENSER THIS WIRING IS TYPICAL OF I I III <br /> 3 11 1 1 I I L__ - ALL OTHER DISPENSERS. I III I <br /> 92 �' __._ I I I I I L----- _ _� 2d0 VOLTS TO UNLEADED PUMP {.-.--_ _ I III <br /> POWER FOR DISPENSER LIGHTS I I I I L.------_ --r- TO EMI, EM2, EM3, EM4, EMS, EMS 4. PUMP PILOT LIGHTS SHOWN ON THIS DRAWING ARE MOUNTED <br /> M2 AIW FOR ALL DISPENSERS I { LL------ - ---- TO TERMINAL STRIP ON THE DOOR OF THE SYSTEM MANAGER CABINET. 240 VOLTS TO SUPER UNLEADED PLMP -_- <br /> _ _________ {� TO PUMP PILOT LIGHT <br /> I L IN REMOTE CASHIER _ TERMINAL STRIP IN <br /> L-- ---------- CONTROL CENTER 5. ALL OVER-URRENT PROTECTION PROVIDED BY OTHERS. 240 VOLTS TO DIESEL PUMP ___-_-_-_-_ -_ _ REMOTE CASHIER <br /> CONTROL CENTER <br /> 6. THE CIRCUIT NUMBER SHALL BE VERIFIED FROM <br /> --- I PROJECT SPECIFIC PANEL SCHEDULE INFORMATION - <br /> NOTE: <br /> SATELLITE EOUIFMENT <br /> WIRINGS AND CONDUIT PUMP/DISPENSER CONTROL5 CONNECTION DI,4GRAM (TYPICAL WITHIN "All) <br /> B7 OTHERS fi <br /> DISPENSER JUNCTION BOX i _ HUGHES BAFdtIERGRCUND TLS-350 MONITOR <br /> SATELLITE 0 SURGE WA As G U7 RAL <br /> E TROL BO F'PRES TO MAN AG L11� • • • <br /> P3-I © Fn�up/016�FLN6ERONTRO <br /> I II <br /> NO TAC HOT( DISP CANOPY HLIGHTS) <br /> a Tg�G3-2 I I DISTRIBUTION I I E I SERVICE PANEL • • • REMOTE MOUNTED CASHIER CONTROL CENTER <br /> RAL $Y5TEM5 MANAGER EMERGENCY SHUTDO(LN SWITCH 8 Xll X 4 <br /> EARTH C-10 �+�" I I BOX = 0 1 I • • • • MOUNTED ON COVER OF II <br /> P3-24 0 I (STARTERS AND PANE I THE CASHIER CONTROL CENTER <br /> q2 WF1 VARISTOR 1 I 3-15 0 I CONTACTORS U II • • • • (NC MOMENTARY) <br /> WITH DISPENSER P3 I PrIP 7 <br /> ASSEMBLY I 1 CA-2 ���' <br /> 01 DISCONNECT SWITCH) • • • • <br /> - _ HO? (LIGNTS7 A-I do I DISPENSER I � Orf <br /> HOT (COMODULE) A-2 O do I I P3-Y OA-3 0 _ 1 MANAGER I NOTE. EACH NRBINE CONTROL • • •�+� SHUT DOWN RESET SWITCH <br /> REPORT Box REQUIRES CONNECTION -mex <br /> T Or <br /> (VA VAC) ) A-4 O IM PRINTER © L _ _ IIAII - _ _ I • �r ®• MOIER C ON COVER TE <br /> EARTH GROUND A-10 O rxrr I I I —1III TO AN INDIVIDUAL arTPUT <br /> jft <br /> I RELAY. CASHIER CONTROL CE-LATER <br /> 1 NEUTRAL (LIGHTS) A-II O u31 I E 1 (NC MOMENTARY) <br /> N UT ( N VALVE POEUER) A-12 ,, u3a • • m m m m <br /> N UT GO MO U ) A-13 w I _R5-232 25 PM _ _ - _ - - +h2 �' fid[ �- RI RI PL] PL] PL3 <br /> N Ut (vA VAC) A-Id UII R5-]3] NI PM I)y GOAx <br /> 9T -I r cENtaa+Ix e l misu,a umu[®s � "p` m I , m m m <br /> T - R ® ® I I I I I I <br /> 1 _ <br /> STP-3 x I CASHIER CONSOL -14 AUy EMEI.Y.aENGT 9HUTDOLLN SWITCH ____ � � I <br /> _ _ _ _ _ _ To I ` I ' I I �I i 16 <br /> TP <br /> TWO WI OUT (-) A,,-S r I" CONDUIT I I <br /> I � SLIP PRINTER ?ERMINAL BLOCKS _______-J� <br /> TWO WIRE IN A-5 - r '12 AW — '12 AWG - - _ _ IN MAIN PANEL =_-_-__ I I FRGIM PUMP PILOT LIGHT <br /> TWOD-W- WIRE OUT GENERIC CRIND B-9 O r 1 P3-11 I ^4 A' -__'- TERMINAL STRIP IN <br /> TU10 WIRE IN GENERIC CRND B-19 r <br /> ePARE A-20 Q T I TCR-I5 0 0 I MAIN CABINET <br /> SPARE A-21 r CONSOLE <br /> 1 SPARE I Q Y I I -SITE 0 0 I 1"G <br /> i SPARE 2 ,• T 1 V3/411 CONDUIT <br /> P3-3 0 MOTORS' I M m'_ <br /> TYPICAL GILBAR. O BLEND DISPENSER 1311ACh4 Awa INTERCOM UNIT A" D. <br /> 3/4"C <br /> I I INTEGRAL <br /> 3/4" CONDUIT (TYPICAL FOR EACH DISPENSER) I _ OVERLOAD EMEFYGENCY SHUTDOWN gWITCH--J <br /> DATA AND CONTROL _ - - '-- _ - PROTECTIONI I MOUNTED ON BUILDING WALL <br /> I I I I I I <br /> (TYPJ I I WIRE COLOR CODES: RIC MOMENTARY) <br /> C • CONDUIT <br /> BK - BLACK AL03 WIRE SIZE <br /> I 74 AW AUXILLARY J-BOX 1 I" CONDUIT !POWER) GROUNDING LUG I I R - RED <br /> 1 R i (TYPJ I E G - GREEN <br /> dc� 3/4"C Y - YELLOW <br /> 3/4" CONDUIT (TLS 350 LErfL RfxJSEB /(.ENC DEiECTOR91 BL - BLUE <br /> LOCATED AT WDEIYiRLrND TANG <br /> — MULTICsRADE D15PENSER INTERCONNECTION DIACsRAM � _ _ — _ _ � P - Pu��� USE APPLICABLE SECTIONS ONLY <br /> 4 REV DATE REVISED E TE � `e° "y APPROVAL RECORD APPROVALS <br /> m UNION OIL OF CALIFORNIA, dba UNOCAL, 1994 pllaT°NE LUTE MPRW& DRAn BY TART <br /> THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN IS ISSUED FOR C.U.P. WKEDBY ELECTRICAL WIRING DIAGRAM <br /> PROPRIETARY TO UNION OIL OF CALIFORNIA (UNOCAL) AND HAS _ _,.__ FUELING SYSTEM <br /> BEEN FURNISHED IN CONFIDENCE AND ARE SUBJECT TO THE ISSUED FOR PLAN CHECK PEO" p 1mN01pN) °"K <br /> TERMS OF A SEPARATE SECRECY AGREEMENT BETWEEN UNOCAL °PRwE° <br /> ISSUED FOR GEN. BID <br /> AND THE RECIPIENT. THE RECIPIENT IS NOT TO COPY, DUPLICATE <br /> °� y_g_gg <br /> OR DISCLOSE THE CONTENTS TO ANY PERSON OR ENTITY EXCEPT - - •amu. wuf�Rl Dw NC No. RE No. <br /> ssuED FOR coNSTRUCT <br /> KET <br /> AS EXPRESSLY AUTHORIZED BY SAID AGREEMENT OR BY UNOCAL — . ] PRODUCTS COMPANY OF <br /> IN WRITING. -- - REcoRD DRAWING zx NONE _ °` — Glees <br /> a�m bN TN N�1 <br /> A B C D E F K:\UN\UN1682\JDWGS\STD-J-7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.