My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2006 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2115
>
2300 - Underground Storage Tank Program
>
PR0526335
>
BILLING 2006 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2023 11:53:42 AM
Creation date
11/7/2018 12:12:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2006 - 2008
RECORD_ID
PR0526335
PE
2351
FACILITY_ID
FA0017819
FACILITY_NAME
7 ELEVEN 2369-39858A
STREET_NUMBER
2115
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
2115 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\2115\PR0526335\BILLING 2006 - 2008.PDF
QuestysFileName
BILLING 2006 - 2008
QuestysRecordDate
6/22/2016 6:54:53 PM
QuestysRecordID
3124912
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
��� 0 -7 faint � <br /> O IFIED PROGRAM CONSOLIDATED FORFI <br /> TANKS \fib <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 �1 <br /> (Two pages per tank) <br /> Page_of_ <br /> TYPE OF ACTION ® 1.NEW PERMIT ❑ 4.AMENDED PERMIT ❑ 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one item ordy) ❑ 3.RENEWAL PERMIT ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reesoa) (Specify reason) ❑ 8.TANK REMOVED <br /> BUSINESS NAME(S.as FACILITY NAME m DBA-Wing lhimss As) 3. FACILITY ID: I. <br /> Great American Gas&Car Wash /��1 q <br /> LOCATION WITHIN SITE(optiow) -7-Pro Sr 431. <br /> I.TANK DESCRIPTION <br /> (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local <br /> TANK ID p 432. TANK MANUFACTURER 433. COMPARTMENTALIZED TANK Yes No 434. <br /> 2A Containment Solutions If"Yes,"complete one page for each compammem <br /> DATE INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS 437 <br /> (YEAR/MO) <br /> 2006/9 12,000 2 <br /> ADDITIONAL DESCRIPTION(Fm local ux only) 438. <br /> IL TANK CONTENTS <br /> TANK USE 439. PETROLEUM TYPE 440. <br /> ® I. MOTOR VEHICLE FUEL ❑la. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (Ifcheckd,complain Pevoleum Type) ®lb. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑Ic. MIDCRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (from naardous Material.Inventory page) 441 CASN(from Haaminus Materials lnvemory page) 443_ <br /> ❑ 4. HAZARDOUS WASTE <br /> Oncludm UW oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK 0 1. SINGLE WALL [33. SINGLE WALL WITH EXTERIOR ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL [14, SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ❑1. BARE STEEL 3. FIBERGLASS/PLASTIC El 5. CONCBETE 0 95.UNKNOWN as4. <br /> (Check one item only) [12, STAINLESS STEEL [14, STEEL CLAD W/FIBERGLASS 08. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCEDPLASTIC FRP W/100%METHANOL <br /> TANK MATERIA.-secondary tank ❑1. BARE STEEL ❑3. FIBERGLASS/PLASTIC ®8. FRP COMPTIBLE W/100%METHANOL [195.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑S. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING 0 95.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING ❑4.PHENOLIC LINING ®6.UNLINED ❑99.OTHER <br /> Check one item only) <br /> OTHER CORROSION ❑1.MANUFACTURED CATHODIC ®3.FIBERGLASS REINFORCED PLASTIC ❑95.UNKNOWN 448. DATE INSTALLED aae. <br /> PROTECTION PROTECTION [14.IMPRESSED CURRENT ❑99.OTHER <br /> If licable ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEARINSTALLED 450, TYPE 451. OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) ®1.SPILL CONTAINMENT 2006 ®1.ALARM 2006 ❑3.FILL TUBE SHUT OFF VALVE <br /> ®2.DROP TUBE 2006 ®2.BALL FLOAT 2006 ❑4.EXEMPT <br /> ®3.STRIKER PLATE 2006 <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453. IF DOUBLE WALL TANK OR TANK WITH BLADDER 45a <br /> (Check all that apply) (Check one item only) <br /> ❑1. VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2.AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE ®2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> ❑4. STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99.OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455_ ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456. TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons ❑Yes ❑ No <br /> PPCF hwfwrc-b(1/99)-1/4 http://www.unid"s.org Rev.02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.