EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
707
>
2300 - Underground Storage Tank Program
>
PR0505151
>
COMPLIANCE INFO 2013 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2023 9:30:02 AM
Creation date
11/7/2018 12:23:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2015
RECORD_ID
PR0505151
PE
2361
FACILITY_ID
FA0007815
FACILITY_NAME
QUICKI KLEEN CAR WASH
STREET_NUMBER
707
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
707 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\707\PR0505151\COMPLIANCE INFO 2013 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2015
QuestysRecordDate
7/19/2016 10:55:15 PM
QuestysRecordID
3146588
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HFULIVU) <br /> JAN 21 2015 <br /> D. Results of TestinglServicing <br /> ENVIRONMENTAL <br /> Software Version Installed. Flc�•TIJ)`r-05PT11411i <br /> Com late the 11owin checklist: <br /> ® Yes ❑ No' Is me audible alarm operational? <br /> ® Yes ❑ No' Is the visual alarm operational? <br /> ® Yes ❑ No' Were all sensors visually inspected,functionally tested,and Will I III operational? <br /> ® Yes ❑ No' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper <br /> operation? <br /> ❑ Yes ❑ No• If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.,modem)operational? <br /> ® N/A <br /> ❑ No' For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment monitoring system tla leek, <br /> ® Yes <br /> ❑ s'.which sensors initiate positive soul-down? (Check all that apply) ® SumpSump/Trench <br /> N/A fails to operate, or is electrically disconnected? If ye <br /> Sensors; ®Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks antl sensor failure/disconnection? ®Yes; ❑No. <br /> l warning <br /> ❑ Yes ❑ No' For tank— prevention valve is <br /> N/A installed),systems <br /> overfilutilize <br /> wlarning alarm lvisible and audible ring system as atthe tanmmary k(Ikpoin counts)and operating device f so.anical at what perp nt of tank capacity <br /> does the slam trigger? % <br /> ❑ <br /> —yes ® No Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced and list the manufacturer name <br /> and model for all replacement pans in Section E,below. <br /> ❑Yes• ® No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑product; ❑Water. If yes,describe causes in Section E,below. <br /> ® Yes ❑ No' Was monitoring system set-up <br /> reviewed to ensure proper settings?Attach sal up reports,H applicable <br /> ® <br /> Yes <br /> ❑ No. <br /> Is all monitoring equipment operational per manufacturers specrfications? <br /> •In section E below,describe how and when these deficiencies were or will be corrected. <br /> E. commems: 87 Spill bucket—bad cap. Retested and passed. <br /> Monitoring System Certification Page 2 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.