My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
707
>
2300 - Underground Storage Tank Program
>
PR0505151
>
COMPLIANCE INFO 2013 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2023 9:30:02 AM
Creation date
11/7/2018 12:23:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2015
RECORD_ID
PR0505151
PE
2361
FACILITY_ID
FA0007815
FACILITY_NAME
QUICKI KLEEN CAR WASH
STREET_NUMBER
707
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
707 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\707\PR0505151\COMPLIANCE INFO 2013 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2015
QuestysRecordDate
7/19/2016 10:55:15 PM
QuestysRecordID
3146588
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Y � <br /> 0&4 - <br /> y� )D V ,� � SA JOAQUIN COUNTY / I/!/kf 6 <br /> /_..--�'" ENVIRONMENTAL HEALTH DEPARTMENT �(Y" " li <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax:(209)468-3433 Web:www sioov ora/ehd ID <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTI UED <br /> FacilityInspection Oct 161, 2013 <br /> h 707 E Yosemite Facility Ouicki Kleen Car Wase Ave, Manteca Date <br /> Name. Address. <br /> VIOLATIONS <br /> HSC=CA Health and Salet Code;CFR=Code of Federal R ulations <br /> # C1 C2 M Code Section Ci -Class 1 violation;C2-Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) twill <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (Mt) <br /> 703 CCR 2643(d) I Tnennial line test for conventional suction piping not performed(pre-January 1,1984) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report'for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS][,or MINOR-Notice to CommilI <br /> Onsite to conduct a routine underground storage tank inspection and observe monitoring system <br /> certification conducted today. <br /> Class II Violations: <br /> . Financial responsibility documents have not been submitted to the EHD in a timely manner. <br /> Current financial responsibility documents are required to t -ubmitted annually. A copy of current <br /> financial responsibility documents were submitted to the EHD at the time of inspection. CORRECTED. <br /> G�r4'U—1 <br /> 204. The designated operator failed to document all the alarms from the attached alarm history on the <br /> f April 4, 2013 designated operator monthly inspection report and failed to check that they were <br /> responded to appropriately. The missing alarm included: L4 alarm on March 31, 2013. During the <br /> monthly inspection, the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history <br /> ith documentation taken in response to any alarms to the monthly report. Ensure that designated <br /> operators performing monthly inspections at this facility are including all of the required information on <br /> the reports. CORRECT D. <br /> Mino otice to Coo�rtply: 1 ` <br /> and 06. USty Operating Permit Application, UST Tank Information, and UST Monitoring <br /> Ian were not uploaded in CERS. Immediately log into CERS, update the required information, and <br /> s mi for review by the EHD. Complete a separate tank form for each tank. <br /> 3. The diesel sump sensor was raised appr p he tank saddle and o lowe <br /> point of the sump and not located to detect a leak at the earliest opportunity. Monitoring equipment shall <br /> be maintained to be able to detect a leak at the earliest possible opportunity. At the time of inspection <br /> technician relocated the diesel sump sensor to the lowest point of the sump. CORRECTED. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br /> Received By: Title: <br /> nepedo <br /> EHD 23-02 Rev 64/19/12 <br /> Page 3 UST INSPECTION REPORT <br />