Laserfiche WebLink
VAW SAN JOAQUIN COUNTY "1111111110' <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov OrQ/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Fadlity Ouicki Kleen Car Wash Faplar 707 E Yosemite Ave, Manteca Inspection Oct 16, 2013 <br /> Name: <br /> Address: Date: <br /> VIOLATIONS <br /> HSC=CA Health and Saffety RCodeCFRode of Federal R ulatimsN C4 :2 M Code Section Ci=Class1Notation;Ction;M=Minor violationNon-Premurimd Pipin (continue702 CCR 2643(¢) Biennial tightness test of gravity piping not perfouary 1,1984) (Mt)703 CCR 2643(d) Triennial line test for wnventional suction piping (pre-January 1,1984) (Mt) <br /> Other Violations <br /> ggg Other: See attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> Onsite to conduct a routine underground storage tank inspection and observe monitoring system <br /> certification conducted today. <br /> Class II Violations: <br /> 104. Financial responsibility documents have not been submitted to the EHD in a timely manner. <br /> Current financial responsibility documents are required to be submitted annually. A copy of current <br /> financial responsibility documents were submitted to the EHD at the time of inspection. CORRECTED. <br /> 204. The designated operator failed to document all the alarms from the attached alarm history on the <br /> April 4, 2013 designated operator monthly inspection report and failed to check that they were <br /> responded to appropriately. The missing alarm included: L4 alarm on March 31, 2013. During the <br /> monthly inspection, the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history <br /> with documentation taken in response to any alarms to the monthly report. Ensure that designated <br /> operators performing monthly inspections at this facility are including all of the required information on <br /> the reports. CORRECTED. <br /> Minor-Notice to Comply: <br /> 105 and 106. UST Facility Operating Permit Application, UST Tank Information, and UST Monitoring <br /> Plan were not uploaded in CERS. Immediately log into CERS, update the required information, and <br /> submit for review by the EHD. Complete a separate tank form for each tank. <br /> 303. The diesel sump sensor was raised approximately 4 inches up the tank saddle and off the lowest <br /> point of the sump and not located to detect a leak at the earliest opportunity. Monitoring equipment shall <br /> be maintained to be able to detect a leak at the earliest possible opportunity. At the time of inspection <br /> technician relocated the diesel sump sensor to the lowest point of the sump. CORRECTED. <br /> ALL END STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPEC ION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br /> Nara n^— R ld Tae: <br /> AI [ i�1 <br /> EHD 23-02 Rev 04/19/12 Pape 3 UST INSPECTION REPORT <br />