Laserfiche WebLink
0 <br /> I <br /> / KCJ Engineering Inc. <br /> y 25431 Cabot, Suite 109 Client: California Hazardous <br /> Laguna Hills, CA. 92653-55:Project: F-ENC07 Vent Line Enclosure <br /> Tel (949) 380-8186 Date: 1/13/2009 <br /> Fax 949 588-1664 <br /> i <br /> . Tank Designed by Others <br /> . See California Hazardous <br /> i . Use 130 MPH Basic Wind Speed, Exposure C <br /> e All Steel to be A36 or Equal, UNO <br /> . Use 2006 International Building Code (2007 California Building Code) <br /> t <br /> General Enclosure Dimensions <br /> i <br /> H Total Enclosure Height 70 in. <br /> W Total Enclosure Width 16 in. <br /> L Total Enclosure Length 21.5 in. <br /> H' Height to Vertical Centroid 35 in. <br /> Loading <br /> General Enclosure Wei hDead Load <br /> 16 Gauge design thickenss = 0.0566" <br /> Steel Density = 450 PCF <br /> Weight 16 Gauge sheet= 450 PCF x 0.056671 2.13 PSF <br /> Total Weight= 2.13 PSF x 6' x 2' x 4 sides 103 Ib <br /> Seismic <br /> Assume Cs = 1 (Worst Case) <br /> Fp 103 Ib <br /> Steel Enclosure Page 1 <br />