Laserfiche WebLink
MONITORING SYSTEM EQUIPMENT CERTIFICATION <br /> State and local laws regulations require that equipment which monitors tanks and/or piping systems containing hazardous <br /> materials be testedlserviced annually or on a schedule specified by the manufacturer,whichever is more frequent. This form, or a <br /> service report with equivalent information,must be used to document testing and servicing of monitoring equipment. If more <br /> than one monitoring system(e.g. Veeder-boot TLS-350,Ronan X76S,etc.)is installed at the facility, a separate certification or <br /> report must be prepared for each monitoring system by the technician who performs the work. <br /> Date of Testing/Servicing: 3-24-00 Facility Name: She]] <br /> Site Address: 1071 N.Main St. City: Manteca Zip: 95336 <br /> Facility Contact Person: Contact Phone No.: (209)823-5365 <br /> Make/Model of Monitoring System: Veeder Root/Simplicity Location of Control Panel: Back Room <br /> Make/Model of Line Leak Detector(LLD): Feeder Root/PLLD LLD Leak Threshold: 3.0 d.p.h. <br /> Complete the following checklist. <br /> X Yes No* Monitoring system isoperable per manufacturer's specifications? <br /> X Yes No* Audible alarm isoperational? <br /> X Yes No* Visual alarm isoperational? <br /> X Yes No* Monitoring system is secured from unauthorized tampering? <br /> X Yes No* For pressurized piping systems,do the turbines automatically shut down if the monitoring system detects a leak, fails <br /> to operate,or is electrically disconnected? if yes,which monitoring devices initiate positive shut down? <br /> NIA <br /> PLLD/Sump Sensors <br /> i <br /> X Yes No* For monitoring systems which serve as tank overfill warning devices,does the overfill warning function operate <br /> properly? If so,at what percent of tank capacity does the alarm trigger? 90% <br /> NIA <br /> *In the comments section below,. describe how and when these deficiencies will be corrected. <br /> Check the appropriate boxes to indicatespecific equipment ins ected/serviced; <br /> Tank ID No.: Regular Tank ID No.: Premium Tank ID No.: Waste Oil Tank ID No.: <br /> Annular Space Sensor X Annular Space Sensor Annuiar Space Sensor Annular Space Sensor <br /> Piping Sump Sensor X Piping Sump Sensor Piping Surnp Sensor Piping Sump Sensor <br /> X In-Tank Gauging Probe X In-Tank Gauging Probe In-Tank Gauging Probe in-Tank Gauging Probe <br /> Dispenser Containment Sensor(s) X Dispenser Containment Sensor(s) Dispenser Containment Sensor(s) Dispenser Containment Sensor(s) <br /> Mechanical Line Leak Detector Mechanical Line Leak Detector Mechanical Line Leak Detector Mechanical Line Leak Detector <br /> X Electronic Line Leak Detector X Electronic Line Leak Detector Electronic Line Leak Detector Electronic Line Leak Detector <br /> Fill Sump Sensor Fill Sump Sensor X Fill Sump Sensor Fill Sump Sensor <br /> TLM Sump Sensor TLM Sump Sensor TLM Sump Sensor TLM Sump Sensor <br /> Are impact valves operational per manufacturer's specifications? X I YES NO <br /> Comments: <br /> I certify that the equipment identified above was inspected/serviced in accordance with manufacturers' guidelines. <br /> Attached to this Certification is information(e.g.manufacturer's checklist,etc.) necessary to verify that the above <br /> information is correct and to describe any repairs,replacement,or recalibration of equipment. <br /> Name of Qualified Technician(print): John Talbott Signature: Signature on file at SSS <br /> Testing Company Name: Service Station Svstems,Inc. Phone No.: (408)971-2445 <br />