Laserfiche WebLink
STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD ° <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> 1 <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION PERMANENTLY CLO ON SIT <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE B TANK REMOVED LICI <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN <br /> A OWNER'S TANK I.D.# B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYNEAR) D. TANK CAPACITY IN GALLONS: <br /> II.TANK CONTENTS IFA-1 IS MARKED,COMPLETE ITEM C. <br /> A. 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C, to REGULAR UNLEADED 3 DIESEL ❑ 6 AVIATION GAS <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY 1 PRODUCT ❑ 1b PREMIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 85 UNKNOWN ❑ 2 WASTE ❑ 1C MIDGRAOE UNLEADED ❑ 5 JETFUEL ❑ 8 M85 <br /> ❑ 2 LEADED ❑ 99 OTHER(DESCRIBE IN ITEMD.BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OFSUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C,AND ALL THATAPPLIES IN BOX D AND E <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCHLIC ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (PmMfy Tmk) ❑ 9 BRONZE ❑ 10 CALV4117FD STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY UNING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING ❑ 8 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100°/6 METHANOL? YES_ NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL,8[0. SPILL CONTAINMENT INSTALLED(YEAR) OVEflFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROPTUBE YES_ NO STRIKERPLATE YES_ NO_ DISPENSER CONTAINMENT YES NO <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGROUNDOR U IF UNDERGROUND.BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑1 NccN4Mau UNE LEAK ❑2 UNE TIGWKV; ❑3 CONDNU S IWERSi 4 ELEMMIC UNE 5 AWOM I'M MW <br /> DETECTOR TESTING MONITORING ❑ LEAK DETECTOR ❑ SHUTDOWN ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 MANUAL RECONCILATIONINVENTORY F-13 MOORING ❑ 4 GAUGNGAUTOMATIC TANK E]5 GROUND MONTORINGTER ❑ 6 TANNUAL <br /> ESTINGTANK <br /> ❑ 7 CONTINUOUS MONITORING INTERSTITIAL ❑ 8 SIR ❑ 9 WEEKLY MANUAL ❑10 MONTHLY TANK E::] 95 UNKNOWN ❑ 99 OTHER <br /> TANK GAUGING TESTING <br /> VI.TANK CLOSURE INFORMATION(PE ANENT CLOSURE IN-PLACE) <br /> 1.ESTIMATED DAT jiSE (MO/DAY 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? YES ❑ NO❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK OWNER'S NAME <br /> (PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW j <br /> COUNTY# JURISDICTION# FACILITY# TANK# OY/ <br /> STATE LD:# /oma <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION �L1 <br /> DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICA N-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FO MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br /> LOT <br /> SHOULD BE ACCOMPANIED BY A PPULE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE w <br /> GROUND STORAGE TANK REGULATIONS <br /> FORM B (6-95) <br />