My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
2230
>
2300 - Underground Storage Tank Program
>
PR0231170
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 2:46:04 PM
Creation date
11/7/2018 4:43:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0231170
PE
2381
FACILITY_ID
FA0003580
FACILITY_NAME
ANDYS AUTO PARTS
STREET_NUMBER
2230
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15535002
CURRENT_STATUS
02
SITE_LOCATION
2230 E MAIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\2230\PR0231170\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
12/29/2016 10:58:28 PM
QuestysRecordID
3302617
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROL BOARD <br /> FORM 'B': WORGROUND STORAGE TANK AGRAM �'"'� <br /> TANK PERMIT APPLICATION INFORMATION Y�N <br /> TANK <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TAN . <br /> MARK ONLY 11 NEWPERMIT ❑3 RENEWALPERMIT L ,CHANGE OF INFORMATION 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT / AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑6 TANK REMOVED <br /> CLOSED <br /> 1�I <br /> FACILITY/BITE NAME WHERE TANK IS INSTALLED: 7�� gr✓ V C FARM TANK.YES❑ NO <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY •O <br /> A. OWNERS TANK IDN I B. MANUFACTURED BY: V, <br /> C. YEAR INSTALLED W <br /> D. TANK CAPACITY IN GALLONS: /,coo <br /> 11. TANK CONTENTS IF(A.i),IS MARKED,COMPLETE ITEM C.IF(Ai),IS NOT MARKED,COMPLETE ITEM 0. O <br /> CT[ <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑�,2 PETROLEUM B. C. ❑ 1 UNLEADED F-12 LEADED ❑3 DIESEL <br /> 3 CHEMICAL PRODUCT IJ ` OIL ❑ 1 PRODUCT ❑1 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑BO EMPTY ❑ 95 UNKNOWN F�2 WASTE ❑7 METHANOL f 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED A C.A.S.N G(/ SDG.V C.A.S.N: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,A D <br /> A TYPE OF ❑ I WUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER 01�95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALLED ❑ /SECONDARY CONTAINMENT ❑99 OTHER <br /> B.TANK ❑ 1�EUI� ❑2 STAINLESS STEEL 3 FIBERGLASS ❑/STEEL CUD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL 2 R ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM a IOD%MMmOLCOMPATIBLEFRP <br /> 9 BRONZE ❑ 10 GALVANIZEDSTEEL ❑95 UNKNOWN ❑ 99 OTHER <br /> C. INTERIOR ❑ I RUBBER LINED ❑2 AIKYDUNING ❑3 EPOKYUNING ❑/PHFNOUCUNING <br /> LINING ❑ 5 GLASS UNING ❑6 UNLINED UNKNOWN <br /> ❑ISUNINGMATERIAL COMPATIBLE WITH IDO%MERIANOL7 ❑YES ❑NO OTHER <br /> D.CORROSION ❑ 7 POLYETHLBTE WRAP ❑2 TAA OR ASPHALT ❑3 VI WMP ❑/FIBERGLASS REINFORCED PJSTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE 95 UNNN0IAN 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U I SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A V I STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A V 1 FIBEflGU$S PIPE A U 91 NONE <br /> PIt C.MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A' U 7 STEEL CUD W/FRP A U B IOD%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER _ <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> 1(AT P S I VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P 6 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 6 5 GROUND WATER MONITORING WELLS <br /> P 8 6 PRECISION TESTING P S 7 PRESSURE TESTING P 8 91 NONE P 8 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE UST USED(MO/YR) 2. ESTIMATED OUANTITY OF <br /> SUBSTANCE REMAINING IN GALLONS U. WAS TANK FILLED WITH <br /> INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED 6 SIGNATURE) DATE <br /> 1 <br /> LOCAL AGENCY USE ONLY <br /> UNTYN JURISDICTION AGENCY N FACILITY IDR TANK ID N <br /> Q� E�� <br /> CURB'F LOCAL AGENCY FACILITY 101 APPROVED BY NAME PHONE I WITH AREA CODE <br /> Ij L FD v 15 Z127- <br /> PEPMtTNIUMMBEFI PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CNECKI PERMIT AMOUNT SURCHARGE AMT. FEE COO! <br /> RECEIPT N BY: <br /> T <br /> FORM B(629-88) THIS FORM MUST BE ACCOYPANIE FACILITY/STIE APPLICATION, FORM 'A',UNLESS A eWENT FORMA' HAS BEEN FILED <br /> ��. DATA PROCF.SSINr /Olno <br />