My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1985-1994
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
2460
>
2300 - Underground Storage Tank Program
>
PR0231171
>
BILLING 1985-1994
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 2:56:03 PM
Creation date
11/7/2018 4:44:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985-1994
RECORD_ID
PR0231171
PE
2381
FACILITY_ID
FA0001657
FACILITY_NAME
PAISANO MARKET
STREET_NUMBER
2460
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15544033
CURRENT_STATUS
02
SITE_LOCATION
2460 E MAIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\2460\PR0231171\BILLING 1985-1994.PDF
QuestysFileName
BILLING 1985-1994
QuestysRecordDate
9/6/2017 11:07:45 PM
QuestysRecordID
3626878
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br /> � STATE WATER RESOURCES CONTROL BOARD A" <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION• FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> °•,,. <br /> MARK ONLY ❑ i NEW PERMIT ❑ 3 RENEWAL PERMIT <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ ❑ 5 CHANGE OF INFORMATION <br /> 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE01 7 PERMANENTLY CLOSED O <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: -� a TANK gEMOVED <br /> I, TANK DESCRIPTION COMPLETE ALL ITEMS-- SPECIFY IF UNKNOWN <br /> FAWNERS TANK I.D.a <br /> B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYNEAR) <br /> D. TANK CAPACITY IN GALLONS: <br /> IIJA�N_K�CONTENTS IFA-11S MARKED,COMPLETE ITEM C. vvv <br /> A. III 1 MOTOR VEHICLE FUEL ❑ 4 OIL B IS REGULAR <br /> f�❑'i�2 PETROLEUM ❑ 80 EMPTY ��--yy C ❑ UNLEADED ❑ 3 DIESEL ❑ 6 AVIATION GAS <br /> `o yfl 1 PRODUCT ❑ 1b PREM[UM ❑ 4 �SAHOL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN /❑ 2 WASTE I;le2 LEADED ❑ 5 JETFUEL ❑ 7 METHANOL <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> III. TANK CONSTRUCTION MARKONE ITEMONLYINBOXESA,B,AND C.AND ALL THAT APPLIES IN BO%D ANDE O A.S.a: <br /> A. TYPE OF I DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER <br /> SYSTEM 2 SINGLE WALL ❑ 4 ❑ 95 UNKNOWN <br /> SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> B. TANK 1 BARE STEEL ❑ 2 STAINLESS STEEL <br /> I�'� ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ <br /> (PrimaryTank) ❑ 9 BRONZE 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN <br /> ❑ 99 OTHER <br /> ❑ ❑ 2 ALKYD LINING <br /> C.INTERIOR 1 RUBBER LINED ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING ><6 UNLINED ❑ <br /> 99 OTHER <br /> 95 UNKNOWN ❑ <br /> IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL S <br /> VES_ No <br /> D.CORROSION ❑ I POLYETHYLENE WRAP ❑ 2 COATING <br /> PROTECTION 5 CATHODIC PRO ❑ 3 VINYL WN ❑ 9 FIBERGLASS REINFORCED PLASTIC <br /> ❑ TECTION 91 NONE <br /> E]95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENiINSTALLEO(YEA R) <br /> IV. PIPING INFORMATION CIRCLE A IFABOVEGROUNDOR U IF UNDERGROUND,BOTH ETION EQUIPMENT INSTALLED <br /> F APPLICABLE YEAR) <br /> A. SYSTEM TYPE U 1 SUCTION A U 2 PRESSURE <br /> B. CONSTRUCTION A U 3 GRAVITY A U 99 OTHER <br /> SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH <br /> A U 95 UNKNOWN A <br /> C. MATERIAL AND A 1 DARE STEEL 99 OTHER <br /> CORROSION A 5 ALUMINUM A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> PROTECTION A U e CONCRETE U 7 STEEL 5 COATING <br /> A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTI A U 95 ON A U B 100% METHANOL COMPgTIBLE W/FRP <br /> D. LEAK DETECTION ❑ 1 AUTOMAT ❑ 2 LINE IC LINE LEAK DETECTOR UNKNOWN A U 99 OTHER <br /> TIGHTNESS TESTING 3 A <br /> V.TANK LEAK DETECTION MDNIroRINc 99 OTHER <br /> ❑❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUNDWATER MONITORING <br /> 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING 91 NONE <br /> ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ES ATE DATE LAT ED IMO/DAYNR) 2.ESTIMATED QUANTITY OF k <br /> SUBSTANCE REMAINING '4L 0 3.WAS TANK FILLED WITH <br /> GALLONS INERT MATERIAL? YES ❑ NO❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME <br /> (PRINTED a SIGNATURE) <br /> DATE <br /> LOCAL AGENCY USE ONLY THE STATE I.D. <br /> STATE I.D.# NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW �L 2 <br /> COUNTYN JURISDICTION# FACILITY� /� / <br /> � TANK# <br /> [PERM:ITNUMBER <br /> HERMIT APPgOVEO BY/DATE <br /> PERMIT EXPIRATION DATE �'- <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORM A,UNLESS A CURRENT FORMA HAS BEEN FILED. (/ <br /> FORM B (12-91) <br /> FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> FOROWO&R6 / <br /> I A�Lj <br />
The URL can be used to link to this page
Your browser does not support the video tag.