My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1985-1994
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
2460
>
2300 - Underground Storage Tank Program
>
PR0231171
>
BILLING 1985-1994
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 2:56:03 PM
Creation date
11/7/2018 4:44:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985-1994
RECORD_ID
PR0231171
PE
2381
FACILITY_ID
FA0001657
FACILITY_NAME
PAISANO MARKET
STREET_NUMBER
2460
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15544033
CURRENT_STATUS
02
SITE_LOCATION
2460 E MAIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\2460\PR0231171\BILLING 1985-1994.PDF
QuestysFileName
BILLING 1985-1994
QuestysRecordDate
9/6/2017 11:07:45 PM
QuestysRecordID
3626878
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> •e f STATE OF CALIFORNIA �+`„„• r <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION • FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. °•fl.o•� <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ ❑ 5 CHANGE OF INFORMATION 7 PERMANENTLY CLOSED ON SI <br /> 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE <br /> e TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: � f <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.# <br /> C. DATE INSTALLED(MO/DAWYEAR) B. MANUFACTURED BY: <br /> D. TANK CAPACITY IN GALLONS: D A.aAi1 <br /> II.TANKCONTENTS IFA-1 IS MARKED.COMPLETE ITEM C. vV(/ <br /> A. �1 MOTOR VEHICLE FUEL ❑ 4 OIL B 1a REGULAR <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY .��Ly�y+++ C. ❑ UNLEADED 3 DIESEL ❑ 6 AVIATION GAS <br /> pal 1 PRODUCT ❑ 1b PREMIUM 4 GASAHOL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN /❑ p WASTE UNLEADED ❑ 5 JET FUEL ❑ 7 METHANOL <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OFSUBSTANCE STORED 2 LEADED ❑ gg OTHER (DESCRIBE IN ITEM D. BELOW) <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B.AND C,AND ALL THAT APPLIES IN BOX D AND E C.A.S.#; <br /> A. TYPE OF 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER <br /> SYSTEM 2 SINGLE WALL ❑ ❑ B5 UNKNOWN <br /> 4 SECONDARY CONTAINMENT (VAULTEDTANK) El 99 OTHER <br /> B. TANK 1 BARE STEEL ❑ 2 STAINLESS STEEL <br /> ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE 7 ALUMINUM <br /> (PrimaryTank) ❑ 9 BRONZE ❑ ❑ 6 100% METHANOL COMPATIBLE W/FRP <br /> ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING <br /> `- ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING IY'6 UNLINED <br /> ll��--��"ff ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? <br /> VES_ NO_ <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING <br /> PROTECTION113 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> ❑ 5 CATHODIC PROTECTION 91 NONE <br /> ❑95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INS TALLED(MAN) <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH EF APPLICABLE TION EOUIPMEN7INSTALLED YEAR) <br /> A. SYSTEM TYPE U 1 SUCTION A U 2 PRESSURE <br /> B. CONSTRUCTION A A U 3 GRAVITY p U 99 OTHEq <br /> SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH <br /> C. MATERIAL AND A 1 BARE STEEL E U 95 UNKNOWN p I 99 OTHER <br /> CORROSION A 5 ALUMINUM A U 2 CONCRETE STEEL A U 3 STEELPOLYW/INYLCOATING <br /> CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> PROTECTION A U 8 CONCRETE A U 7 STEEL W/COgTING <br /> A U 9 GALVANIZED STEEL q U 10 CATHODIC PROTECTION A U 6 10095 METHANOL COMPATIBLE W/FRP <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR A U 95 UNKNOWN A U 99 OTHER <br /> ❑ 2 LINE TIGHTNESS TESTING ❑ MONRORING OTHER <br /> V.TANK LEAK DETECTION <br /> ❑❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> B TANK TESTING ❑ 7 INTERSTITIAL MONITORING 91 NONE <br /> ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.EST APED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF rf. <br /> SUBSTANCE REMAINING H7 GALLONS 3 WAS TAN MATERIA ITH <br /> YES ❑ NO❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME <br /> (PRINTED 6 aIGNATBgEI DATE <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW G <br /> COUNTY# JURISDICTION# FACILITY <br /> STATE I.D.# TANK# <br /> [TPE-RM:ITNUMBER ERMIT A.P. BY/DATE <br /> PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FORM B (1291) <br /> FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> r 1 <br /> • A�i����� FOgO¢XBg6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.