Laserfiche WebLink
0 fmFIED PROGRAM CONSOLIDATED FORM //n I (0ANK: TA0505759 <br /> PR PR0231665 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 FA <br /> TYPE OF ACTION <br /> Chak only item only) ❑ I NEW SITE PERMIT ❑4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> ®3 RENEWAL PERMIT ® ❑8TANNREMOVED CLOSED ON SITE <br /> El 43D <br /> BUSMSSNAME(Se NFACILITYNAME«DBA-Doing Bmi«tss Aa) FACILITY ID: PR#: I <br /> LACHHAR CHEVRON* FA0003714 PR0231665 <br /> LOCATION WITHIN SITE(clpdmep 334 E MAIN ST,RIPON 431 <br /> PHONE <br /> 1.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be subadt ed to the local agency.) <br /> TANK ID# Tank#: 7 43z TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑ Yes ❑No 434 <br /> TA0505759 XERXES I"=',mmplpco«pegsachmmpmmmt. <br /> DATE INSTALLED(YEAR/MO) 433 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 8/1/1995 12:00:OOAM 12,000 <br /> ADDITIONAL DESCRIPTION(F«Imal am owy) 438 <br /> D.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® L MOTOR VEHICLE FUEL ❑ la.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (Ihns.kMm Iasepelmlmm Type) ® Ib.PREMIUMUNLEADED ❑ 3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑2.NON-FUEL PETROLEUM ❑ le MIDGRADE UNLEADED ❑ 4.GASOHOL ❑W.OTHER <br /> ❑3.CHEMICAL PRODUCT COMMON NAME umm xaoudmes Malcdals lmct«y pegs) 441 CAS#(6om xa mame Mabia6ly xnmry page) <br /> ❑4.HAZARDOUS WASTE 4n <br /> (1«Iwauaedop) 8006-61-9 <br /> ❑95.UNKNOWN <br /> UL TANK CONSTRUCTION <br /> TYPE OF TANK ❑ I.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 44 <br /> (Chakmciivn my) EXTERIOR MEMBRANE LINER El 95.UNKNOWN <br /> ® 2.DOUBLE WALL ❑4.SINGLE WALL IN VAULT ❑99.OTHER <br /> TANK MATERIAL-primary tank ❑ 1.BARE STEEL ® FIBERGLASS/PLASTIC ❑5.CONCRETE ❑ 95.UNKNOWN 444 <br /> (Chackme item only) ❑2.STAINLESS STEEL ❑ STEEL CLAD W/FTBERGLASS ❑8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99.OTHER <br /> TANK MATERIAL-secondary tank ❑ L BARE STEEL ® 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (Chechomitem retry) ❑2.STAINLESS STEEL ❑ 4.STEEL CLAD W/FIBERGIASS ❑ 8.FRP COMPTIBLE W/107%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ 1.RUBBER LINED ❑ 3.EPDXY LINING ❑ 5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED "7 <br /> OR COATING <br /> (Clack.iten red,) ❑2ALKYD LINING ❑ 4PHENOLIC LINING 916UNLINED ❑ 99.OTHER <br /> (For local use only) <br /> OTHERCORROSION ❑ I MANUFACTURING CATHODIC ® 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UN1NOWN "a DATE INSTALLED 445 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Click ore item my) E] 4 IMPRESSED CURRENT El99OTHER❑ 2SACRIFICW.ANODE (F«I«aluu«dy) <br /> SPILL AND OVERFILL YEAR MSTALLE450 TYPE(Inialnmmy) 451 OVERFILLPROTECTION EQUIPMENT'YEARINSTALLED 452 <br /> (Clack ill J�at tsps],) M 1 SPILL CONTAINMENT 1,995.00 ® I ALARM ®3 FILL TUBE SHUT OFF VAL` <br /> 1f❑ 2 DROP TUBE 1,998.00 OP W 61 SO 4 ❑ 2 BALL ❑4 EXEMPT <br /> ❑X 3 STRIKER PLATE FLOAT <br /> TV.TANK LEAK DETECTION(A c1mriptim ofwc mo h-,p,,g=shall k sumnnmd to the local egad y.) <br /> IF SINGLE WALL TANK(Cheskell that tsps],) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ I VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Chan*one inial mly) <br /> ❑2AUTOMATIC TANK GAUGING(ATG) ❑ fiVADOSE ZONE <br /> ❑ 1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑3 CONTINUOUS ATG ❑ 7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 453 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 437 <br /> ❑Yes ❑ No <br /> UPCF(12/99 revised) <br />