My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
334
>
2300 - Underground Storage Tank Program
>
PR0231665
>
COMPLIANCE INFO 2005 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2022 11:40:43 AM
Creation date
11/7/2018 4:53:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2015
RECORD_ID
PR0231665
PE
2361
FACILITY_ID
FA0003714
FACILITY_NAME
LACHHAR CHEVRON*
STREET_NUMBER
334
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
26115041
CURRENT_STATUS
02
SITE_LOCATION
334 E MAIN ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\334\PR0231665\COMPLIANCE INFO 2005 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2005 - 2015
QuestysRecordDate
3/7/2017 12:38:04 AM
QuestysRecordID
3348427
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
224
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITNG SYSTEM CERTIFITION <br />se By All Jurisdictions Within the State of Califomi <br />Authority Cited: Chapter 6.7, and Safety Code; Chapter 16, Division 3 Title 23, omia Code of Regulations <br />This forth must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility, a separate <br />certification or report must be Prepared for each monitodno system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system ownedoperator. The owner/operator must submit a copy of this forth to the local agency regulating UST systems within 30 days of test date. <br />A General Information <br />Facility Name: CHEVRON 91452 (N-618) <br />Site Address: 334 E. MAIN ST <br />0o HWY 99 <br />Facility Contact Person: DEALER- MOHINDER <br />City: RIPON <br />Contact Phone No: 599-2313 <br />Date of Testing/Service: 01/08/2008 <br />Make/Model of Monitoring System:TLS 350 Work Order Number: 2253817 <br />IS. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced <br />CA <br />Zip: 95366 <br />Tank ID: 1-91 <br />Tank ID: 2-89 <br />_R1 In -Tank Gauging Probe. <br />Model: MAG -1 <br />X In -Tank Gauging Probe. <br />Model: MAGA <br />X Annular Space or Vault Sensor. <br />Model: 409 <br />Annular Space or Vault Sensor. <br />Model: 409 <br />71 Piping Sump/Trench Sensor(s). <br />Model: 208 <br />Piping Sump/trench Sensor(s). <br />Model: 208 <br />Fill Sump Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />)( Electronic Line Leak Detector. <br />Model: PLLD <br />X Electronic Line Leak Detector. <br />Model: PLLD <br />X Tank Overfill/High-Level Sensor. <br />Model: E/A <br />Tank Overfill/High-Level Sensor. <br />Model: E/A <br />Other (specify equipment type and <br />model in Section E on page 2). <br />Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: <br />Tank ID: <br />71 In -Tank Gauging Probe. <br />Model: MAGA <br />In -Tank Gauging Probe. <br />Model: <br />X Annular Space or Vault Sensor. <br />Model: 409 <br />Annular Space or Vault Sensor. <br />Model: <br />X Piping Sump/Trench Sensor(s). <br />Model: 208 <br />Piping SumpfTrench Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />X Electronic Line Leak Detector. <br />Model: PLLD <br />Electronicline Leak Detector. <br />Model - <br />Tank Overfill/High-Level Sensor, <br />Model: E/A <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />Others <br />( pacify equipment type and model in Section E on page 2). <br />Dispenser 1/2 <br />Dispenser ID: 3/4 <br />M Dispenser Containment Sensors) <br />Model:208 <br />_Xj Dispenser Containment Sensor(s) <br />Model: 208 <br />IFX1I Shear Valve(s). <br />X Shear Valve(s) <br />❑ Dispenser Containment Float(s) and Chain(s). <br />-- Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5/6 <br />DispenserlD: 7/8 <br />x—]Dispenser Containment Sensor(s) <br />Model:208 __Xj <br />Dispenser Containment Sensor(s). <br />MWa1:208 <br />XJ Shear Valve(s). <br />71 Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Floats) and Cham(s). <br />Dispenser ID: <br />Dispenser ID: <br />Dispenser Containment Sensor(s) <br />Model: <br />Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />Shear Valve(s). <br />to Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />If the facility contains more tanks or dispensers, copy this forth. Include information for every tank and dispenser at the facility. <br />C. Certification <br />I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this certification is information (e.g manufacturers' checklists) necessary to verify that this information is correct. <br />and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached <br />a copy of the (Check all that apply): ❑X System set-up X❑ Alarm history report <br />Technician Name (print): HEATH MCEVER <br />Certification No.: A27562 <br />Signature: <br />License. No.: <br />Testing Company Name:Tanknology Phone No.: (800) 800-4633 <br />Site Address: 8501 N. MoPac Expressway, suite 400, Austin, TX 78759 Date of Testing/Servicing: 01/08/2008 <br />Monitoring System Certification Page 1 of 3 Based on CA form dated 03/01 <br />