My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
400
>
2300 - Underground Storage Tank Program
>
PR0231903
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2024 4:30:48 PM
Creation date
11/7/2018 4:57:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231903
PE
2381
FACILITY_ID
FA0003569
FACILITY_NAME
Main Street Stockton, LLC
STREET_NUMBER
400
Direction
E
STREET_NAME
MAIN
STREET_TYPE
St
City
Stockton
Zip
95202
APN
14915024
CURRENT_STATUS
02
SITE_LOCATION
400 E Main St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\400\PR0231903\BILLING 1987-1999.PDF
QuestysFileName
BILLING 1987-1999
QuestysRecordDate
9/5/2017 7:55:32 PM
QuestysRecordID
3624282
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE <br /> ATEB :: F CALIFO NO WATER RESOURCES CONT BOARD <br /> UNDERGROUND STORAGE TANK PR GRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED NK <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE �8 TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: Do �, , MO f nj FARM TANK-YES❑ NO <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN- '0 <br /> $O SPECIFY 10 <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: !. Do a <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A,1),IS NOT MARKED,COMPLETE ITEM D. CN <br /> CJ 1 <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL w <br /> ❑ 3 CHEMICAL PRODUCT OIL ❑F-�1 PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS tb <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY E:] 95 UNKNOWN ©2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D.BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF L <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# W U' S l CD r C.A.S.# 0 <br /> x111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑ 1 DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEEUIRON ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B. MATERIAL F-] 5 CONCRETE ❑ 6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑ B 100%METHANOL COMPATIBLE FRP <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C. INTERIOR <br /> r-] 2 ALKYD LINING 3 EPDXY LINING 4 PHENOLIC LINING I RUBBER LINED ❑ ❑ ❑ <br /> LINING ❑5 GLASS LINING ❑ 6 UNLINED ❑ 95 UNKNOWN <br /> ❑ ISLINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D. CORROSION ❑ I POLYETHLENEWRAP ❑ 2 TAR OR ASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑ 91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 3 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P 3 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> �W P 3 6 PRECISION TESTING P S 7 PRESSURETESTING 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> A y1. ESTIMATED DATE LAST USED(MO/YR) 2. GALLONS ESTIMATED QUANTITY OF 3, WAS TANK EILLED WITH <br /> /1//{ SUBSTANCE REMAINING IN INERT MATERIAL? ❑YES ❑ NO <br /> /✓/ 1 <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> p <br /> L AGENCY FACILITY ID# APPROVED BY Nye PHONE#WITH AREA CODE <br /> /� �'d�PERMIT APPROVAL DATE PERMIT EXP RATION D TE <br /> PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FORM B(3-7-BB) THIS FORM MUST BE ACCOMPANI FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY , <br />
The URL can be used to link to this page
Your browser does not support the video tag.