Laserfiche WebLink
WORK ORDER 74729 <br /> CUSTOMER JOB LOCATION DATE: (( LO-15' <br /> CUSTOMER COMPANY CHEAPER CONTACT: JOHN JOHNSON <br /> P.O. BOX 886 890 NORTH MAIC•! STREET ORD <br /> BENICIA, CA. 94510 MANTECA, CA. 95336 SSTA=N 7- <br /> 707-745-6691 205'-239-4550 <br /> --------------------------------------------------------------------------------------------- <br /> MECHANICAL LEAK DETECTOR TEST FORM <br /> ------------------------------- ----------------------------------------------------- <br /> REG/UNL _, SUPREME/UNL _, PREMIUM/UNL DIE.;EL _ (CIRCLE ONE & IDENTIFY OCTANE) <br /> SUBMERGED PUMP MFG.: R I <br /> LEAK DETECTOR MFG.: � MODEL tt //L- D ? S SERIAL <br /> TYPE: DIAPHRAM ZC PISTON OTHERS (Tamper Proof Seal? _ yes IA-- no <br /> -------------------------------LEAK DETECTOR OPENING TIME TEST ------------------------------ <br /> 1. Turn an Pump and record the step-through time from 0s <br /> to full pressure. _7 sec <br /> ( Approximately 3 Secondsi <br /> FUNCTIONAL ELEMENT OPERATION TEST <br /> 2. Pum Running Pressure '�5- psi 3. Shut-off Pressure �_ psi <br /> ( 29 to 35 psi normal ) ( 8 to 20 psi normal ) <br /> --------------------------------------------------------------------------------------------- <br /> RESILIENCY TEST ( BLEEDBACK ) <br /> 4. Drain and measure amount of product from shut-off pressure to 0 psi 3 7 S ml <br /> ( 50 - 110 ml for diaphragm type and 350 - 410 ml for Piston type ) <br /> ------------------------- -------------------------------------------------------------------- <br /> 10 psi CALIBRATION <br /> 5. Using the calibration valve, create the proper leak rate @ 10 psi- <br /> Confirm test <br /> si.Confirmtest leak-@--- /9 2 ml per minute. <br /> ----- -- ----------------------------------------------------- <br /> SIMULATED LEAK TEST <br /> 6. With the simulated leak in the line active, dispense product from the nozzle. <br /> Confirm flow rate through the nozzle @ �,.� gallons per minute. <br /> --------------------------------------------------------------------------------------------- <br /> BOTTOM LINE <br /> 7. There are two tests the leak detector must pass in order for it to be considered <br /> acceptable. <br /> LEAK: DETECTOR OPENING TIME TEST ( 1 ) LEAK SIMULATED TEST ( 6 ) <br /> Diaphragm type (between 2 and 3 seconds) Flow rate through nozzle <br /> Piston type (between 2 and 3.5 seconds) (between 1.5 and 3 gallons per .minute) <br /> XFAIL <br /> PASS PASS FAIL <br /> S7EiFlf3Fa'E7f}iFlf]flfiFif%aE3E lfififif iElEiFiF3F3Fif3Fif 3f1f 1EiF]F1Eif1fi43F1E3f3f3FifiF M.rklFif3f3FiF3fifiFllf 3f iiiFiF43E{c 3F 3FiFif3E3f3F3fif3f1F 43FiiiF±F <br /> LEAK. DETECTOR <br /> MUST PAUSBSfH-TEST IN u7 <br /> PASS FAIL <br /> * <br /> PERFORMED BY T€CHNICIAN: LF16 K R�NSACRAnENIU (Z <br /> 2533 CONNIE DRIVE - SACRAMENTO - CA. - 9815 <br /> 916-92S-2716 <br /> ar\cu\i\b\ldjw <br />