COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
890
>
2300 - Underground Storage Tank Program
>
PR0231984
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/17/2022 4:12:56 PM
Creation date
11/7/2018 5:37:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231984
PE
2361
FACILITY_ID
FA0001393
FACILITY_NAME
MANTECA LIQUOR & FOOD
STREET_NUMBER
890
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22302007
CURRENT_STATUS
01
SITE_LOCATION
890 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\890\PR0231984\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
3/1/2017 7:11:38 PM
QuestysRecordID
3346092
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone. (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MANTECA LIQUOR & FOOF 890 N MAIN ST MANTF ,ril 18 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> Item # Remarks <br /> N CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to document all the alarms from the attached alarm history on the April 8, 2016 <br /> designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br /> missing alarm includes: L6 diesel submersible turbine pump (STP) sump fuel alarm on April 2, 2016. During the <br /> monthly inspection, the designated operator shall review the alarm history for the previous month, check that each <br /> alarm was documented and responded to appropriately, and attach a copy of the alarm history with documentation <br /> taken in response to any alarms to the monthly report. Ensure that designated operators performing monthly <br /> inspections at this facility are including all of the required information on the reports. <br /> The designated operator failed to visually inspect the under dispenser containment(UDC) for dispensers 1-2 and 3-4 <br /> during the April 2016 monthly inspection. During the April 18, 2016 annual monitoring system certification inspection, <br /> the 208 sensors in both dispensers were found lying down on the bottom of the UDCs. During the monthly inspection, <br /> the designated operator shall visually inspect all spill containers and UDC sumps, and any tank top sump that had an <br /> alarm for which there is no record of a service visit. Ensure that designated operators performing monthly inspections <br /> at this facility are inspecting all of the required areas and noting them on the reports. <br /> Also the designated operator failed to sign the designated operator monthly reports for May 14, 2015 and December 8, <br /> 2015. <br /> This is a minor violation. <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The 208 sensors in both dispensers (1-2 and 3-4)were found lying down on the bottom of the under dispenser <br /> containments. 208 sensors must be placed in an upright position to be functional at all times. All monitoring <br /> equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. The service technician <br /> returned the sensors to their proper locations during the inspection. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on April 18, 2016, the day of inspection. The EHD <br /> has written the complete report on April 21, 2016, which replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Page 6 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.