My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2004-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1206
>
2300 - Underground Storage Tank Program
>
PR0231175
>
BILLING 2004-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:25:36 PM
Creation date
11/7/2018 6:06:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2004-2007
RECORD_ID
PR0231175
PE
2361
FACILITY_ID
FA0001247
FACILITY_NAME
DP & DK Investments, Inc.
STREET_NUMBER
1206
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
1206 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MARCH\1206\PR0231175\BILLING 2004-2007.PDF
QuestysFileName
BILLING 2004-2007
QuestysRecordDate
4/6/2018 9:19:22 PM
QuestysRecordID
3847439
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9RED PROGRAM CONSOLIDATED FOI <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br /> (two pages per tank) <br /> Page_of <br /> TYPE OF ACTION ❑1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ® 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for local use only) (Specify reason-for local use only) ❑ 8 TANK REMOVED 430 <br /> BUSINESS NAME(Sam as FACILITY NAME or DBA-Doing Business As) 3 1 FACILITY ID: 1 <br /> ConocoPhilli s Site#2705445 FM I <br /> LOCATION WITHIN SITE(Optional) 431 <br /> 1206 E March Lane, Stockton, CA 95210 <br /> I.TANK DESCRIPTION (A scaled.plot plan with the location of the UST system including buildings and landmarks shall be sub <br /> agency.) <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK 07eS 0No 434 <br /> 1 lfi Q 1 ,���w XERXES <br /> I("Vas",complete one page for each comportment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 435 NUMBER OF COMPARTMENTS 437 <br /> 01/01/1991 9728 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> .: >.IL.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> 1811. MOTOR VEHICLE FUEL ® la. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (If marked complete Petroleum Type) ❑1 b. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION FUEL <br /> [12. NON-FUEL PETROLEUM ❑ic. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441 CAS#(ham Hazardous Materials Inventory Page) 442 <br /> ❑4. HAZARDOUS WASTE <br /> (Includes Used Oil) <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK [31 SINGLE WALL ❑3 SINGLE WALL WITH ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER 095. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SIGNLE WALL IN VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank 0 1. BARE STEEL 0 3. FIBERGLASS/PLASTIC 0 5. CONCRETE 0 95. UNKNOWN 444 <br /> (Check one item only) ❑2. STAINLESS STEEL [14. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE W/ ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) 100%METHANOL <br /> TANK MATERIAL-secondayork 01. BARE STEEL 0 3. FIBERGLASS/PLASTIC 0 5. CONCRETE 0 95. UNKNOWN 445 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4.STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) W/100%METHANOL <br /> ❑5. CONCRETE ❑10.COATED STEEL <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING ®95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ❑6 UNLINED ❑99 OTHER <br /> (Check one Item only) (For local use only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC❑3 FIBERGLASS REINFORCED PLASTIC ®95 UNKNOWN 446 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4 IMPRESSED CURRENT ❑99 OTHER <br /> (Check one Item only) ❑2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(local un only) 451 OVERFILL PROTECTION EOUIPMENT:YEAR INSTALLED 452 <br /> (Check all ®1 SPILL CONTAINMENT 20030 1 ALARM ®3 FILL TUBE SHUT OFF VALVE <br /> that apply) <br /> ®2 DROP TUBE 2003 ❑2 BALL FLOAT ❑4 EXEMPT <br /> ®3 STRIKER PLATE 1998 <br /> IV.TANK LEAK DETECTION(A description ofthe monitoring Program shall be submitted to the local agency) " <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one Item only) <br /> ❑1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ❑2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> +(SIR) BIENNIAL TANK TESTING ❑1OTHER <br /> IV,TANK CLOSUREINFORMATION'I PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAV) 455 ESTIMATED QUANTITY OF SUBSTANCE 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> REMAINING <br /> gallons ❑Yes ❑ No <br /> UPCF (1/99 revised) Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.