INSTALL INSTALL PLAN 1997
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2132
>
2300 - Underground Storage Tank Program
>
PR0231669
>
INSTALL INSTALL PLAN 1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:41:19 PM
Creation date
11/7/2018 6:26:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
INSTALL PLAN 1997
RECORD_ID
PR0231669
PE
2361
FACILITY_ID
FA0001480
FACILITY_NAME
TESORO (MOBIL) 68222
STREET_NUMBER
2132
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17306035
CURRENT_STATUS
01
SITE_LOCATION
2132 MARIPOSA RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MARIPOSA\2132\PR0231669\INSTALL\INSTALL PLAN 1997.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IMPACT VALVE STABILIZER BAR '�" 5515/1W <br /> GPW 60V5FG-1001 45" k W <br /> SHEAR VALVE DISPENSER ISLAND 22 1/2' <br /> —� <br /> ANCHOR BAR f _ 33^ Z <br /> I i PUMP IDENTIFICATION NUMBER i� <br /> OPENING FOR I" VAPOR ---- �— PUMP IDENTIF CATION WJMBER <br /> V.R LINE RECOVERY PIPE I 1. I6 I/2' ' I <br /> -- RISER GONG. SLAB ' I (4) 1511&" X 1 T/I6" SLOTS �'- METAL CANOPY, PAINT J <br /> {� __ ____- _ _ -- L-- FOR ANCHOR BOLTS - OR "USA" DECAL v o ''� M O N <br /> T <br /> ENV IRON <br /> TEST BOOT DISPENSER '» moi' _-y, I' COAX WHIP END HOSE <br /> -\ SUMP U Q 'A 'T (3) I/2" SUPPLY UNIONS 23 5/8" / Q U 'y�yr <br /> (2 "7/16" UP FROM BASE) CATLOW aAV200 INVERTED CI iD - <br /> -- ' T' VESPER ROOT - m - _ •r - - (l`�l --- - Y. 48" COAX BREAK AWAY 16' ` m� - <br /> { LIQUID SENSOR ( -- *� .. <br /> 2" AO. SMITH J - N i"Y'4r. 42" <br /> �I/ co <br /> PIPING PIPIN& - -I --- I I (4) 3/4' X 1 1/2" SLOTS v <br /> ENTRY BOOT <br /> g �c - ...-._.-_- _ FOR. ANCHOR BLOTS <br /> I/2" GEOFLEX - ---- --- I <br /> ELBOW FITTING �.--_� GOODYEAR 8'-6" FLEX f O UL <br /> OPENING FOR I/2" Ir _ 12 I/2" OPENING FOR STEEL VAPOR ASS15T r O a <br /> CONNECTOR TUBE SPEAKER CONDUIT I" CONDUIT D COAX VENTURI HOSE OR EO. <br /> (SUGGESTED LOCATION) 135/5'. 9 I/4" <br /> -.� _ <br /> - __ l" <br /> (N) DEEP DISPENSER SUMP a 1 6" P BE11V PORV G. m <br /> V.R. A5515T SYSTEM �n <br /> 24 21 -NOTE: CONTRACTOR MUST VERIFY -I COMPONENTS P I`i �f <br /> X11 IMPACT VALVE 42" DISPENSER MODEL WITH USA p' <br /> STABILIZER BAR - -' REFRESENTITIVE PRIOR TO F <br /> INSTALLATION OF PRODUCT PIPING <br /> SHEAR60V5P6-1001 _ _ COAX NOZZLE <br /> SHEAR VALVE TOP VIEW AT DISPENSER SUMPS. <br /> 015PEN5ER {BLAND F � 1 <br /> ANCHOR BAR I ! Clr <br /> =_ METAL DOOR, PAINT <br /> J CONC SLAB /I I-r T, OR "USA" DECAL <br /> I� I <br /> ------I ___ V ` (l) I" VAPOR DISPENSER BASE <br /> VEEDER ROOT RECOVERY PIPE <br /> / j I 22" DISPENSER ISLAND <br /> 1 LIQUID SENSOR I° GAFFED <br /> r i t VISF NSER J-BOX ELBOW i i (STAINLESS STEEL FORM) <br /> TEST BOOT - /,' _ f 4 - �ISPENSER ISLAND r <br /> �� ENVIRON FRONT _ <br /> ,' �h - SEE PP-1 <br /> _ I FRONT -� <br /> THIS DIMENSION IL FOR <br /> VSE WITH A COUBLE <br /> C POPPET SREAR VALVE <br /> ILL- _1 .__... 1 "-' J - PER PLAN W S, -BLACK GONG. <br /> 2" A.O. SMITH IT E� � _ ENTRY PHOT - ---- ��X I; SLAB > <br /> ]SYS E EG. 5 <br /> PIPING �_ I i T i '�I' _ � I I/I6 � h'-=___ 2 '7/16" I � J <br /> EAL OFF u <br /> 1 ENY!RGN C NTAINMENT CON <br /> C. <br /> 514-5 a CONC. FOOTING <br /> FITTING PER N <br /> /2" GEOFLEX EG 1 <br /> PIPING -TEE FITTING -._.. .__x DISPENSER SUMP <br /> cohnecTGR TUBE51DE VIEW FRONT VIEW -- --- - - - BOTTOM GF -- / <br /> FCOT:NG <br /> (N) DEEP DISPENSER SUMP 10 (N) ADVANTAGE SERIES MPD ELEVATIONS VAPOR RECOVERY COMPONENTS <br /> O,KI. 36` DIA. DUAL-PORT <br /> 18NR MANHOLE 5 GALLON MANHOLE <br /> VOPHALVE! <br /> E! -M IMPACT f GNI a2-2R-8G OPW 6337 OFW I-fIIT VAPOR GAP - GNI 36' <br /> VALVE - MALE <br /> VESPER ROOT �- INTRINSIC SAFE CIRGUI7 FILL CAP -- <br /> --- TANK GAUGE PROBE 1 ' EAS"-IST MA6:+OLE <br /> F W/ GAMLOKS CNI a^Oa5 a <br /> (MODEL x84'13 MAG 2) _ - - EXPLOSION PROOFOFN C <br /> I" CONDUIT TO ' J.O`� J BOX FILL ADAPTER O <br /> -GPW 1611 VAPOR » <br /> y__ <br /> TANK GAUGE SEAL OFF <br /> - _ _ CONTROL UNIT ADAPTER <br /> J — - <br /> - - __ - _ __ �- 70 NEXT TANK . . p1�` _ _.- � _s j <br /> 4" 9 RISER - �— <br /> SASOLINE FLOAT i --- - <br /> _� ----" TANK SLAB 10 <br /> -- - ----- F`) <br /> STABLIZER REP JACKET <br /> BAR ( -- <br /> r 2"m FIBERGLASS SINGLE ) Q <br /> — I I/2" SALVE PTFE L _ 4 :9 RISER WALL PIPE r0 VENT RACK �RON LANK SUMP _�•{' \� ENVIRON <br /> { <br /> WATER FLOAT -y{-d, TEST aOOT O Q ' <br /> W 4 <br /> O U <br /> INTRINSIC SAFE _ (\/ <br /> GiRGUIT <br /> ,�4' DIA. \\ 1 1/2" ENVIRON GEOFLEX O <br /> ( N) IMPACT VALVE (N) TANK GAUOE DETAIL T F GPW 233 - M D RISER - PIPING w SECONDARY <br /> -- - - - - CONTAINMENT S¢ 6 <br /> VARIES SEE PLAN -_-_- W! 53 - VM I __ _....._a Y <br /> EXPLOSION U <br /> PROOF J-eOX <br /> ..-.-}. 1/ RADIIf� �_.-..-..._ VERIFY N "USA" 1,��I/2 MOCNJ aEAL OFF REPRESENTATIVE � � � O <br /> EMGO-WEATONDY D GGNGRETE•p GAIROIANNCONCRETE � rt JERIFY /i/ "VSA' _ -- _ I l __ 2"m GR 3"m A.O. SMIREPRESENTATIVE- i - - - ""� I - -0 PHASE II VR PIPING _ UBBER COMPRESSION <br /> NEW CONDUIT --- --- ` FLEXIBLE ENTRY BOOTS <br /> PER PLAN TEST TUBEBACKFILLSTAINLE55 STEELVEEDER ROOT LIOLEAK SENIOR DET ( oOPW 253 VENT-VM <br /> DISP ISLAND FCR" a1BOTTOM GF TANK (MODEL 794_80- `:_� EXTRACTOR <br /> LOW END-._..-- <br /> PLAN VIEN SEG rIQ�t ) \� D 53-VM <br /> UNDER GROUND STORAGE TANK <br /> N) DISPENSER ISLAND DETAIL 8 (N) FILL PHASE I RECOVERY 4 (N) TURBINE/SUMP 2 <br /> NOTES. 9. ALL TANKS ARE METHANOL COMPATIBLE. <br /> I MONITOR SYSTEMS FOR THE INTERSTICE SHALL B6 BY A LIOVID IO ALL PRODUCT PIPING SYSTEMS ARE PRESSURED. L59 <br /> IN ACC . BY VISUAL DETERMINATION, OR BY AUDIBLE DETERMINATION, FILL WITH GONG. <br /> IN ACCORDANCE WITH DETERMINATION, <br /> LOCAL AND STATE REGULATIONS. II. ALL DISPENSING DEV:G ES SHALL BE U.L. LISTED. , <br /> 2 SACKFILI_ MAY BE SAND, PEA GRAVEL. 3/4" ROUNDED AGGREGATE, 12. THE DISPENSERS SHALL BE NOT CLOSER THAN 10 FEET FROM ANY <br /> OR NATIVE 901E IN ACTIONS NCE WITH MANUFAGT,RERS CURRENT BUILDING F6LAGK � ,f_.._ 3" BLUE CERAMIC '(`� ED W/ CONCRETE <br /> INSTALLATION INSTRUCTIONS. FILL X 1/ STEEL TUBEp <br /> 18" <br /> TILE FLUSH MOUNTED <br /> 13. DISPENSERS SHALL BE AT LEAST 20 FEET FROM ANY SOURCE OF \ <br /> ? SEE DRAWING FOR NUMBER OF FITTINGS, CGNFICJRATION, ACCESS- IGNITION SHEET Tf7lE <br /> STEEL LID <br /> CRIES AND SUMP R15ER DETAILS. � I iPING DETAILS <br /> 14, PRODUCT PIPING SHALL BE TESTED AT 50F51 FOR 30 MIN. PRODUCT '. T <br /> 4. THE DESIGN, ASSEMBLY AND TESTING GF THE PIPING SYSTEM SHALL PIPING SHALL NOT BE CONNECTED TO THE TANK PRIOR TO TESTING ( )/ RED DRAWN BY DRAY/ND <br /> BE IN CONFORMANCE WITH THE APPLICABLE SECTION F AN5131 T� ! I, PER PLAN M.E.M, IIOPP3.DWG <br /> AMERICAN NATIONAL STANDARD DOGE FOR PRESSiRE PIPING, AND IS NO TANKS OR PIPING SHALL BE CONGEALED FRIGR TO FIRE DEPT. ��} WHITE <br /> NEPA 30, FLAMMABLE AND COMBUSTIBLE L SEC GODS. APPROVAL. I JLW �� •a� SCALE JOB k <br /> �!I NATURAL CONCRETE - NOTE VARIES 110 <br /> 5. ALL A550CIATED PIPING SHALL BE PROTECTED FROM CORROSION 16. ALL TEST GAUGES SHALL BE FROVIDEG BY THE INSTALLER THE ro -���T BLUE I FINISH hV HEAVY -- - ---_ SEE PLANS FOR <br /> GAUGES SHALL BE CAlIB7A7ED IN V2 P51 INCREMENTS. -V SANDBLAST FINISH 6 LOCATION DATE STARTED DATE SUBMTTED <br /> 6 TL5-350 WILL BE PROGRAMMED FOR A POSITIVE SMUT DOWN ON j GL055 3-1"3-Ql <br /> PRODUCT PIPING IN CASE OF A LEAK. I7. NO TANKS WILL BE REMOVED. A SHEET SHEET # <br /> -!. VENT, V.R. 6 PIPING LINES FOR TANKS SHALL BE INSTALLED ® I/8" 18. THE FIRE DEPT. AND/GR ENV. HEALTH GEP'T, WILL INSPECT/ APPROVE NATURAL CONCRETE 1� •• - 2"9 DRAIN 4'-0" X 18" DIA. <br /> PER FOOT SLOPE AND SHALL BE SLOPED BACK TO THE TANK FINAL OCCUPANCY SIGN-0FF PRODUCT PIPING HYDRO TEST, AND FlF15H Wi HEAVY I _ - ,• CONC. FOOTING <br /> PRODUCT TANKS. ALL REQUIREMENTS SHALL BE COMPLETED PRIOR - SANDBLAST FINISH ! �4 •_._ . <br /> 8 ALL MANHOLES SHALL BE LIOUID TIGHT, SECURABLE, 6 TRAFFIC TO FINAL OCCUPANCY CLEARANCE. THE FIRE DEPARTMENT SHALL GL055 n <br /> RELATED: BE GIVEN 24 HOURS MINIMUM NOTICE PRIOR TO ALL INSPECTIONS -- - --- '8�9 P■ - J <br /> A - 36" C.N.I EASY LIFT TURBINE MANHOLE II LL OF <br /> B - 36" ON DVALPGRT OVERSPILL PROTECTOR 19. ALL TANK MANHOLES SHALL BA A MINIMUM I" ABOVE GROUND <br /> C - 16" G N.I. MONITOR MANHOLE Lou <br /> K CRETE " TRASH GAN h "OUIK CRETE " PLANTER 5 (N) 51' SO. STEEL POST Tj <br /> 19 ALL PIPING SHALL BE INSTALLED BY MANAFAGTVRES SPEC.-S, <br />