Laserfiche WebLink
V <br /> ROY F. WESTON, INC. <br /> STOCKTON ANALYTICAL LABORATORY <br /> ORGANICS CASE NARRATIVE <br /> Client: PRECISION <br /> RFW # : 89095036 <br /> W.O. #: 5481-01-01-0000 <br /> FRACTION: MODIFIED 8015 (TPH) <br /> 1. This set of samples consisted of 1 soil sample collected <br /> on 09/13/89. <br /> 2 . The sample was extracted on 09/21/89 . <br /> 3 . This sample was analyzed on 10/12/89. <br /> 4 . All required holding times for this sample were met. <br /> 5. All tuning and calibration criteria were met for this sample. <br /> 6. All blanks analyzed were below allowable limits of <br /> contamination as set forth in the EPA CLP SOW. <br /> 7 . Of the 2 matrix spike recoveries, none were outside of QC <br /> limits. <br /> 8 . Of the 1 matrix spike RPD's, none were outside QC limits. <br /> The following data qualifiers are used in this report: <br /> U - Indicates that the compound was analyzed for but not <br /> detected. <br /> J - Indicates an estimated trace value. <br /> Approved by: Date: 10-/9-Se°1 <br /> 1 <br />