My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
25431
>
2300 - Underground Storage Tank Program
>
PR0502153
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2020 11:19:32 PM
Creation date
11/7/2018 6:30:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0502153
PE
2381
FACILITY_ID
FA0005343
FACILITY_NAME
JOHN DA SILVERIA
STREET_NUMBER
25431
Direction
E
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
ESCALON
Zip
95320
CURRENT_STATUS
02
SITE_LOCATION
25431 E MARIPOSA RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MARIPOSA\25431\PR0502153\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
9/14/2017 5:54:26 PM
QuestysRecordID
3636313
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNWATER RESOURCES CONTR, 30ARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PRO RAM _ x= <br /> TANK TANK PERMIT APPLICATION INFORMATION P <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. _- Z <br /> ;O <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑2 INTERIM PERMIT F-] 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE � K REMOVED 10 <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: 3 (�� a Y (' � FARM TANK-YES❑ NO Q- 4h- <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY <br /> r <br /> A. OWNERS TANK IDR V(- B. MANUFACTURED BY: <br /> C, YEAR INSTALLED ILK_ D. TANK CAPACITY IN GALLONS ' <br /> 11. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. OHICLE FUEL ❑ 2 PETROLEUM B C. ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOLTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&CA.S.p KI— C.A.S.R: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,8 D <br /> A TYPE OF ❑ 1 DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALLED 4 SECONDARY CONTAINMENT 99 OTHER <br /> ❑ I STEEL/IRON ❑ 2 STAINLESS STEEL ❑3 FIBERGLASS ❑ 4STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE ❑ 6 POLYVINYLCHLORIDE F-17 ALUMINUM ❑ 8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL Q-9S URKNOWN ❑ 99 OTHER <br /> ❑ <br /> C. INTERIOR 1 RUBBER LINED ❑2 ALKYD LINING F--] 3 EPDXY LINING [-]4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING ❑fi UNLINED t�I/KNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO 99 OTHER u <br /> D. CORROSION ❑ I POLYETHLENEWRAP ❑ 2 TAR OR ASPHALT ❑ 3 VINYLWRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE EJ-96-MNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A Q 69 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U S ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 9 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S I VSUALCHECK P S 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUNDWATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED OUANTITY OF 3, WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ElYES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED A SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY N JURISDICTION M AGENCY M FACILITY ID M TANK ID N <br /> = I ol o a U <br /> CURRENT LOCAL AGENCY FACILITY IDN APPROVED BY NAME PHONE M WITH AREA CODE <br /> r Q a <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK N PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT N BY; <br /> IV FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM `A',UNLESS A CURRENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.