Laserfiche WebLink
SAN JdAQLTIN LOCAL HEALTH DI STFLI CT <br /> MININUM VERIFICATION LABORATORY ANALYSIS <br /> .._ . ro P (5030) (5030) (.1540) <br /> q----- i <br /> TANK CONTENTS TPH G TPH-D I TEPH BTX&E ICL HC I TEL EDB, METALSI FCB it <br /> (Waste Product GC FID 'GC-FID( (3550) 1 (8020) I (8010) (D b H S) i (ICP (8[70) <br /> ( 30 I ( (8240) ; ._ . �. I �) (BU&0) <br /> LEADED GASOLINE X X X <br /> 7 � <br /> UNLGASOLI X _�. _X._._. - ____.._.- ___.._.._..._.._..i.._._.....__ <br /> DIESEL X <br /> R.....KEROSENE.--.._.... -......._. ..— X ---r �_--X __L.._.._.....-...- I ! —...- I-- - _�.._...._-........--..i <br /> N UNKNOWN FUEL X i -- - X X - — 'X-._.._. .. X- <br /> OIL X I X I _...._... ..._..._-_.._�.._.._._.__....._i� <br /> CHLOR. SOLVENTS I X X I I <br /> 1 <br /> NONCHLOR._SOLVTS' - <br /> --_ — - <br /> WASTE/USED OIL X X X X X p <br /> MINIMUM VERIFICATION LABORATORY ANALYSES TERMINOLOGY <br /> The following listing of laboratory analyses abbreviations is provided as a guide so that <br /> terminology used will be more familiar. All analyses methods are designated EPA methods as <br /> described in EPA SW 846, Third Edition. Those methods not found in SW 846, are <br /> specifically noted. <br /> TPH G Total Petroleum Hydrocarbon, Gasoline <br /> TPH D Total Petroleum Hydrocarbon, Diesel <br /> TEPH Total Extractable Petroleum Hydrocarbon (8015) <br /> BTX & E (8020) Benzene, Toluene, Xylene & Ethyl Benzene (8020) <br /> CL HC 8010 OR 8240 Chlorinated Hydrocarbon 8010 or 8240 <br /> TEL (DOHS-LUFT) Tetraethyl Lead (DOHS-LUFT) <br /> EDB (DOHS-AB 1803) Ethylene dibromide (DOHS-AB 1803) <br /> GC FID Gas Chromatography Flame Ionization Detector <br /> ICP-AES OR AA Inductively Couple Plasma Atomic Emission Spectrometry or Atomic <br /> Absorption Spectrometry <br /> Method 5030 Purge and Trap Sample Preparation <br /> Method 3550 Sonication Sample Preparation <br /> Method 3540 Soxhlet Sample Preparation <br /> QA/QC Quality Assurance/Quality Control <br /> Notes: To avoid false positive detection of benzene, benzene-free solvents are to be used. <br /> Fused capillary columns are preferred to packed columns; a packed column may be used as a <br /> "first cut" with "dirty" samples or once the hydrocarbons have been characterized and <br /> proper QA/QC is followed. <br /> For Drinking Water SourcesEPA recommends that the 500 series for volatile <br /> organics be used in preference to the 600 series because the detection limits are lower and <br /> the QA/QC is better. <br />