My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MCALLEN
>
1570
>
2300 - Underground Storage Tank Program
>
PR0504493
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2020 11:19:43 PM
Creation date
11/7/2018 6:46:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0504493
PE
2332
FACILITY_ID
FA0006220
FACILITY_NAME
WEBER RANCH ASSOCIATES
STREET_NUMBER
1570
STREET_NAME
MCALLEN
STREET_TYPE
RD
City
STOCKTON
Zip
95210
CURRENT_STATUS
02
SITE_LOCATION
1570 MCALLEN RD
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MCALLEN\1570\PR0504493\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
10/9/2017 9:26:16 PM
QuestysRecordID
3671931
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
u« e <br /> STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION • FORM B ?a <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ i NEW PERMIT ❑ 3 RENEWAL PERMIT M 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT F74 AMENDED PERMIT 7 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED i <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: 115-7 D C <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.Q# f B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAY/YEAR) D. TANK CAPACITY IN GALLONS: <br /> lilnk <br /> ILTANKCONTENTS IFA-11S MARKED,COMPLETE ITEM C. <br /> A ❑ 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C ❑ 1aUNLEADED ❑❑lbPREMIUM 3 DIESEL ❑ 6 AVIATION GAS <br /> 4 GASAHOL <br /> F-1 80 EMPTY I <br /> ET <br /> UNLEADE <br /> EMPTY <br /> ❑ 3 CHEMICAL PRODUCT U �95 UNKNOWN ❑ 2 WASTEMETHANOL <br /> CT ❑ 2 LEADED D ❑ gg�OTHER L(DESCRIBE IN7ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.4: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B,AND C,AND ALL THAT APPLIES IN BOXD <br /> ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER 5?795 UNKNOWN <br /> A. TYPE OF 99 OTHER <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) ❑ <br /> ❑ 1 SAFE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B. TANK 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE n 7 ALUMINUM ❑ g 100% METHANOL COMPATIBLE W/FRP <br /> MATERIAL ❑ �L✓,r/ <br /> (PrlmwyTmk) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYO LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR ❑ 5 GLASS LINING �/eUNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES �JNNO_ <br /> ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 L WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> D.CORROSION 5 UNKNOWN ❑ 99 OTHER <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND.BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A OTHER <br /> B. CONSTRUCTION A U i SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH U 5 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 6 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION U 5 UNKNOWN LA U 99 O9 F <br /> 1 AUTOMATIC LINE LEAK DETECTOR 2 LINE TIGHTNESS TESTING 3 NiFASTRNL gg OTHER <br /> D. LEAK DETECTION ❑ ❑ MONITORING <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VAPOR MONITORING 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> ❑ e TANK TESTING ❑ 7 INTERSTITIAL MONITORING B1 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLEDWITH �'q� <br /> 1.ESTIM T D DATE LAST USE (MO/DAYIVR) SUBSTANCE REMAINING GALLONS INERT MATERIAL 7 YES ❑ NO XY <br /> III <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> DATE <br /> APPLICANTS NAME <br /> (PRINTED 6 SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FAC TANK <br /> L_J—L�IJ�J <br /> STATE I.D.# 0 <br /> PERMIT NUMBER PERMIT APPROVED SY/DATE PERMIT EXPIRATION DATE <br /> FORM B (9-90) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> 9--- 1 q_ 4 ( ` p- Foaoo eas <br />