Laserfiche WebLink
! 0 <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUNDSTORAGETANK <br /> MONITORING PLAN- (Pae 1 of 2) <br /> TYPE OF ACTION ❑ L NEW PLAN ❑ 2.CHANGE OF INFORMATION <br /> PLAN TYPE ® I.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. A90-2 <br /> [Check one nem only) ❑ 2.THIS PLAY COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> I. FACILITY INFORMATION <br /> FACILI'CY Ill N(Agenry Use Oniy) i_ <br /> 13USINESS NAME(Sams as F=zfhy Name or DBA) Super Store Industries _3.. <br /> BUSINESS SITE ADDRESS 16888 McKinley Ave. tm. CITY Lathrop toa. <br /> 11. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance•and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)most be performed at the Gcquency specified <br /> by the equipment mamrfamurers'inatmeti or annually,whichever is more Re wmr Such work must be pffficamed by qualified persannel.D3 c R§M 2,26.34,Mas,Mall <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): a�3a' <br /> b. <br /> M. MONITORING LOCATIONS ' <br /> ❑ L NEW SITE PLOT PLAN.MAP SUBMITTED WITH THIS PLAN ® 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED4s0.�. <br /> Iz3 cux 3ze32,263at <br /> IV. TANK MONITORING IS PERFORMED:USING THE FOLLOWING N1ETROD(S) rn ca i j' <br /> ® 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULTS) 4903. <br /> WITH AUDIBLE AND VISUAL ALARMS.[23CCR§M ZUNI <br /> SECONDARY CONTAINMENT IS: ❑ a.DRY ® b.LIQUID FILLED ❑ c-PRESSURIZED ❑ d.UNDER VACUUM 4903. <br /> PANEL MANUFACTURER Veeder-Root 490-7' MODEL#: TLS-350 49o4. <br /> LEAK SENSOR MANUFACTURER: Veeder-Root "190'9' MoDEL#(s): VR 302 .!E'[•� X-cS 490-1°. <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WAI..L T NKZS).[23c c §2ew7 <br /> PANEL MANUFACTURER: MODEL#: <br /> IN-'TANK PROBE MANUFACTURER 450da MODEL#(S): J9at5. <br /> LEAK TEST FREQUENCY: ❑ a CONTINUOUS ❑ b.DAILYINIGHTLY ❑ c.WEEKLY 490-16. <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): Oso-Tt. <br /> PROGRAMMED TESTS: ❑ a 0.1&P.h. ❑ b.02&P-IL ❑ c.OTHER(Specify): 09 40-1& <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION Im mR§MM.ij 450-20. <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)jnmitlt ul TESTINGPERIOD: ❑ a36HOURS ❑ b.60 HOURS 49022. <br /> ® 5.TANK INTEGRITY TESTING PER 123 Mk§2643.1! 450-23. <br /> TEST FREQUENCY: ® a ANNUALLY ❑ b.BIENNIALLY ❑ e.OTHER(Specify): 490 50.24. <br /> ❑ 99.OTHER(Specify): <br /> 49026 <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWINGMETHOD(S) ,h"dk I j <br /> ® 1.CON'T'INUOUS MONCCORING OF PIPEiPIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAI.ALARMS. >o0-2s. <br /> l23 R CCSECONDARY CONTAINMENT IS: ® a DRY ❑ b.LI UID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490-z9. <br /> § CC Q <br /> PANEL MANUFACTURER Veeder-Root 490.30. MODEL#: TLS 350 '"0.31 <br /> LEAK SENSOR MANUFACTURER Veeder-Root 49°-32 MODEL#(S): VR 208 490.33. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(La,TURBINE)SHUTDOWN. ❑ a YES ❑ b.NO 49 m <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a YES ❑ b.NO 090.35. <br /> ® 2.MECHANICAL LINE LEAK DETECTOR(MLID)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF 490-36 <br /> PRODUCTFLOW WHEN A LEAK IS DETECTED.[23 CCR§26361 <br /> MLLD MANUFACTURER(S):VMI 99 ' MODEL#(S): LD 2000 465 38. <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g p.h.LEAK TESTS.In CCR§M361 490'35. <br /> ELLD MANUFACTURER(S): 490.d0' MODEL N(S): 490-01 <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 49042 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a YES ❑ b.NO a90'43 <br /> SLID FAILURE(DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a YES ❑ b.NO 490.44 <br /> ❑ 4.PIPE INTEGRITY TFSTING. ---- --�4W45 <br /> TESTFREQUENCY: ❑ a ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify) 49p4.,t90-4u <br /> ® 5.VISUAL PIPE MONITORING. 490)8 <br /> FREQUENCY: ® a DAILY ❑ b.WEEKLY ❑ c.MIN.MONTHLY REACH TIME SYSTEM OPERATED- 490'45 <br /> _ •Atbwedf funbrmN fitl '" W HSC 25281) <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA.W CCR§26Np)(3)I 490'50 <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7IS CONNECTED TO THE TANK SYSTEM. 490651. <br /> ❑ 99.OTHER(Specify) IIW33 <br /> UPCF UST-D(122007)-114 www.unidm.org <br />