My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1987-1989
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MELLO
>
17572
>
2300 - Underground Storage Tank Program
>
PR0502795
>
BILLING 1987-1989
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2021 10:12:08 PM
Creation date
11/7/2018 7:04:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1987-1989
RECORD_ID
PR0502795
PE
2332
FACILITY_ID
FA0005577
FACILITY_NAME
KANG, KENNETH INC
STREET_NUMBER
17572
Direction
E
STREET_NAME
MELLO
STREET_TYPE
AVE
City
RIPON
Zip
95366
CURRENT_STATUS
02
SITE_LOCATION
17572 E MELLO AVE
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MELLO\17572\PR0502795\BILLING 1987-1989.PDF
QuestysFileName
BILLING 1987-1989
QuestysRecordDate
9/13/2017 4:47:20 PM
QuestysRecordID
3635152
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNI& WATER RESOURCES CONTRI OARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATIONo „ <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. z <br /> .o. <br /> MARK ONLY F-11 NEW PERMIT ❑ 3 RENEWAL PERMIT E25CHANGE OF INFORMATION El7 PERMANENTLY CLOSED TANK eo <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑B TANK REMOVED - f� <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: G`. FARM TANK-YES NO ❑ F-i <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY 00 <br /> A. OWNERS TANK ID# 1 B. MANUFACTURED BY <br /> C. YEAR INSTALLED 1 ' D. TANK CAPACITY IN GALLONS: nc,- <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL ❑ 1 PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 60 EMPTEj�Y 4EUNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# CAS,#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,B D <br /> A. TYPE OF ❑ 1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ I STEEL/IRON ❑2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK MATERIAL ❑ 5 CONCRETE E] 6 POLYVINYLCHLORIDE E] 7 ALUMINUM ❑8 100%METHANOL COMPATIBLE FRP <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL D 5 UNKNOWN ❑ 99 OTHER <br /> C. INTERIOR F-] 1 RUBBER LINED El2 ALKYD LINING ❑ 3 EPDXY LINING 1:14 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING ❑ 6 UNLINED L 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D. CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TAR OR ASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑AYUNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE U- 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLEWALLED A U 3 LINED TRENCH A U 91 NONE U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL AL_*UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1VISUALCHECK P S 2 INVENTORY RECONCILIATION P S 3VADOSEWELLS S 4ELECTRONIC MONITOR P S 5 GROUNDWATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P $ 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? YES_[]JN <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> CURREN�}OCAL AGENCY FACILITY IDN APPROVED BY NAME PHONE#WITH AREA CODE <br /> nDAEoQl /' <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPTN B <br /> 77 <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIAWA FACILRY/SITE APPLICATION, FORM 'A',UNLESS A RENT FORMA' NAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.