My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1985-1992
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MELLO
>
19201
>
2300 - Underground Storage Tank Program
>
PR0503661
>
BILLING 1985-1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2021 12:14:34 AM
Creation date
11/7/2018 7:06:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985-1992
RECORD_ID
PR0503661
PE
2381
FACILITY_ID
FA0005931
FACILITY_NAME
SKS ENTERPRISE
STREET_NUMBER
19201
STREET_NAME
MELLO
STREET_TYPE
AVE
City
RIPON
Zip
95366
APN
20612003
CURRENT_STATUS
02
SITE_LOCATION
19201 MELLO AVE
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MELLO\19201\PR0503661\BILLING 1985-1992.PDF
QuestysFileName
BILLING 1985-1992
QuestysRecordDate
8/29/2017 5:30:19 PM
QuestysRecordID
3610239
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNO WATER RESOURCES CONTROARD <br /> FORM `B': UNDERGROUND STORAGE TANK PRO RAM " <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. - <br /> MARK ONLY ❑ 1 NPWERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM Ew�21NTERIM PERMIT ❑ 4 AMENDED PERMIT ,A El TEMPORARY TANK CLOSURE ❑8 TANK REMOVED Q2- <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: � I_/ FARM TANK-YES❑ NO CJI <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY A <br /> A. OWNERS TANK ID# S-..2- I B. MANUFACTURED BY: v <br /> C. YEAR INSTALLED VAlk, D. TANK CAPACITY IN GALLONS: <br /> II. TANK CqNTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. MOTOR VEHICLE FUEL ❑ 2 PETROLEUMC. E] 1 UNLEADED ❑ 2 LEADED IESEL <br /> F--] 3 CHEMICAL PRODUCT ❑ B.4 OIL PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED 8 C.A.S.# ,/V C.A.S. <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&O <br /> A.TYPE OF ❑ 1 DOUBLEWALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINEA KNOWN <br /> SYSTEM ❑ 2 SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> EEUIRON E] 2 STAINLESS STEEL F-13 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.MANN <br /> MATERIAL F-] 5 CONCRETE ❑ 6 POLYVINYLCHLORIDE F-17 ALUMINUM ❑ 8100%METHANOL COMPATIBLE FRP <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C. INTERIOR <br /> ❑ 1 RUBBER LINED ❑2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENO CLINING <br /> LINING ❑ 5 GLASS LINING ❑6 UNLINED UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TAR OR ASPHALT ❑23,VWRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE AX)1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A 5 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8100%METHANOL COMPATIBLE ERP <br /> A U 9 GALVANIZED STEEL A 195 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> PS 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST US O M /YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES E] NO <br /> THIS FORM HAS B EN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> aE 16 10 <br /> CURRENT LOCAL AGENCY FA ILITY ID# APPROVED BY NAME 6 (X HONE#WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PE MIT EZPIRATIO ATE <br /> CHECK# PERMITAMOUNT RCHARGE AMT. FEE CODE CEIPT# BY: <br /> FORM B(6-29-88) THIS FORM MUST BEACCOMPANIEM A FACH ITY/SITE APPLICATION, FORM 'A',UNLESS A RENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.