My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1995
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MINER
>
1950
>
2300 - Underground Storage Tank Program
>
PR0504240
>
INSTALL_1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/9/2019 9:26:42 AM
Creation date
11/7/2018 7:19:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1995
RECORD_ID
PR0504240
PE
2361
FACILITY_ID
FA0006136
FACILITY_NAME
QUICK TRUCK REPAIR
STREET_NUMBER
1950
Direction
E
STREET_NAME
MINER
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
15308006
CURRENT_STATUS
02
SITE_LOCATION
1950 E MINER AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\M\MINER\1950\PR0504240\INSTALL\1995 INSTALL .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
y <br /> NOTESm'ar'e. <br /> 1 . LOCATE OUTLET BOX 6 INCHES ABOVE WIREWAY. GENERAL NOTES: _ <br /> 1 . ALL CONDUIT TO BE 3/4" <br /> CD <br /> 2. BRING CONDUIT TO JUST INSIDE BUILDING, STUB UNLESS SPECIFIED OTHERWISE. <br /> C� <br /> AND CAP 12 INCHES AFF. 2. ALL # 16 WIRING TO BE r — — — — — — — — — — — — — CL `0 <br /> 3. PROVIDE 3 SEPARATE CONDUITS TO EACH MASTED STRANDED UNLESS SPECIFIED <br /> OTHERWISE. � 00� <br /> DISPENSER AS FOLLOWS: 3. PROVIDE 6" MIN. CLEARANCE <br /> a. DISPENSER PULSER WIRING AND DISPENSER BETWEEN CONDUIT AND F.R,P. 12,000 GAL. <br /> SOLENOID FOR POS COMPUTER. PIPING. <br /> (41114 & 1 /{ 16 GRD.) GASOLINE <br /> SUMP 0-)� TANK <br /> (TYP.) O <br /> b. DISPENSER ELECTRIC AND PUMP CONTROLLERM <br /> _ <br /> // <br /> WIRING. (4# 14 & 1 #16 GRD.) I / / 3/4 HP <br /> P \ I1 <br /> c. SUMP SENSORS. – �,t Ln <br /> (EMPTY CONDUIT WITH FISHWIRE) I - <br /> I -- Jf ENT FILL a <br /> 4. PROVIDE EMPTY CONDUIT WITH FISHWIRE, I EEDER—ROO O ' W 1J- <br /> 5. CONSULT WITH PENSKE PROJECT MANAGER TO LOCATE l 1 i Q <br /> THE TERMINATION OF ALL CONDUITS RUN INSIDE BUILDING. \(TILS-350) i I m <br /> . LEGEND <br /> 7�t�17� Z <br /> LEGEND <br /> X LOCATION OF SEAL-OFF � I I � � '> <❑ I i <br /> QWcl:� <br /> 1 '—EMERGENCY STOP i CC7 0_ Q <br /> j PUSHBUTTON a <br /> I (LOCATE TO SATISFY O Q <br /> LOCAL CODES) I I <br /> LINE LEAK <br /> DETECTOR �} i ACCESS M NHOLES FOR <br /> 2#14 & 1 //14 GRD. ° SENSOR---/ '1 1 I I INTERSTITIA SPACE PROBES <br /> 1 2#14 & <br /> 11114 GJ1 — L � <br /> j GASOLINE r L4------ i ' <br /> I MASTER DISPENSER # 1 -'JJ <br /> l i VEEDER-ROOT <br /> �4# 14 & 1 # 14 GRD. "\ INTERSTITIAL SPACE i i (TLS-350) i I <br /> --- ' _ TYP. FOR ALL SENSOR — i i i I i i PUMP t Q <br /> 101114 & 1 /(14 GRD., i"C. �} SFE NOTE 3 I i i I I CONTROLLER Z ' <br /> TO MANAGER'S OFFICE "------------------------------------------------------ _ _( uI <br /> INTERCOM ---------------------- --------------------- ----------— - ------- -- ---------------------- - ---nr-1 MASTER DISPENSERS) � I SUMP I <br /> CONDUIT TO TELEPHONE BACKBOARD{ ---------------- ----------" -----------' ------------------------- - -- n 1 I <br /> TELEPHONE`r------------------------^ --III SENSOR <br /> MANAGER'S IPUMP CONTROLLER "------------------------------ ---- ------- ---------- �-- - <br /> --------------------- -------- <br /> TO --- � III I I I i i i I 3#10 & 1 �J10 F- <br /> OFFICE DISPENSER ELECTRIC"----------------------------- ----------------------- I--------------- _ <br /> —i iii 1 1 GRD., 3/4` C. � J <br /> SUMP SENSOR (SEE NOTE 4) `r'------- -------- --------- ---- ------------------- - - -- 111 III i I <br /> ( --------------------------------- <br /> SUMP SENSOR SEE NOTE 4) 5----------------- ---------- ---1111 III I I <br /> CONDUIT INSIDE BUILDING SPARE CONDUIT (SEE NOTE 2)" -- - - ____--__^___ —111 111 III I INTERCOM OUTLET I I I <br /> ( _--------- ------- ---------__---- <br /> (SEE NOTE 2) TO <br /> cRNPAN SEE NOTE --------------- ----------- ' (SEE NOTE 1 ) I 1 i GRD. & 11� i Z <br /> - . TO POWE12 PANELBOARD------------------------- ------- --------------------- � - GRD. � I I Q ' <br /> 3#3 & 1 #8GRD., 1 1 /4"C. <br /> ltffl TELEPHONE OUTLET <br /> INTERSTITIAL UNE MONITOR FOR DOUBLE WALL TANKS "-----------------7 111 DISPENSER I I <br /> LINE LEAK DETECTOR SENSORS "--- -----------------------1 PANELBOARD "K" ° lit '�' (SEE NOTE 1 ) ELECTRICAL i i I 4 <br /> TO MANAGER'S SUMP <br /> SENSORS <br /> (SEE NOTE 4) .------------------------1 I 1 f 2#14 & 1 #14 GRD. <br /> OFFICE VEEDER—ROOT 4-------------------------------1 I I ' { -- -------- -------- I 1 I Q <br /> fMN�'''��� --------------- <br /> -/---- --------------- <br /> PUMP CONTROLLERS 5------------------ -----'t I I 1 I I .. c --� — ---- --- ---------- — I I 1 I I <br /> 1 I 1 DISPENSER 1� SUMP SENSOR <br /> I I I I I I I V) <br /> t 1 i ELECTRICAL (EMPTY CONDUIT <br /> ' 1 i t <br /> 2# 14 & 1 #14 GRD. —� WITH FISHWIRE} ° � 1 I I _ IPI/ZPP _—__I � � [� } J <br /> I 1 1 ------------- -----------'-_----------- _ -r- "� " W <br /> 1 I I ------------`---`--'- ------`--- DIESEL MASTER DIESEL SATELLITE i i <br /> 1 I i i I SUMP SENSOR DISPENSER #2 DISPENSER #2 1 r—I-- ^-- __.,. �_._I Li- <br /> (EMPTY <br /> i <br /> (EMPTY CONDUIT I i i J VEBr F1 1 <br /> I i WITH FISHWIRE) ° <br /> DIESEL MASTER 1 1 L_� - VEEDER-ROC _ I -� iColl <br /> DIESEL SATELLITE DISPENSER #3 <br /> ' DISPENSER #3CANOPY (TLS- <br /> COLUMN 1 Itl f <br /> 0 (TYP.) <br /> ---� ANCHOR i I <br /> 1 IGNAL HOSE SIGNAL HOSE ON TOP (TYP,) I j <br /> NDERGROUND IN CONDUIT OF ISLAND SLAB <br /> VEND <br /> I CAP <br /> 1 1 i 1 1 <br /> I I I I I I I i <br /> l l i i i I 20,000 GAL. <br /> 1 1 1 1 1 I I I DIESEL I I <br /> TANK <br /> I I I I 1 I I I I i t <br /> I I I I 1 I i I I I I <br /> ' ' 1 ------------------------------------ 4/114 & 1IIt4 cRD. <br /> I 1 ---------------------------------------- ------------------------ -------------------------------------- -----I —U ' I <br /> --- -- — ------ <br /> L ----- ----- — <br /> -------------------------------------------------------------------- -----1--- I I <br /> L------------------------------------------- ------------------------------------------------------------- ------------------- ---J ' I U1 <br /> --------- ---------- <br /> __------------------- ---- ------------------- ----------------------------------------------------- - ---' L <br /> �6#10 & 1 #10 GRD., 1"C. 4# 14 & 1 #14 GRD. O <br /> w <br /> J <br /> Q <br /> FUEL ISLAND CONDUIT PLAN <br /> SCALE: 3/8" = t '-0" <br /> `) <br />