Laserfiche WebLink
y <br /> _ AMCADD r' IL FDAJ-T1 <br /> G SERVICES J r <br /> � -ar ri of 12: I8 <br /> 1135 E. Alosta Avenue <br /> Suite 103 <br /> Glendora, CA 91740 <br /> (818) 857-7388 <br /> August 23, 1995 <br /> San Joaquin County <br /> Public Health Services <br /> Environmental Health Division <br /> % Ms. Letitia Briggs <br /> 445 N. San Joaquin <br /> Stockton Ca. 95201 <br /> Re: Penske Truck Leasing <br /> 1950 E. Miner Ave./"A" Street <br /> Stockton, Ca. 95205 <br /> INFORMATION ON UST'S AND PIPING TO BE USED AT THE SITE: <br /> Dear Ms. Briggs: <br /> The intent is to update and clarify the information that was provided to you in the letter accompanying the <br /> permit application submittal. The proposed equipment to be used at the above mentioned construction site is <br /> listed on all Penske Truck Leasing Standard Drawings included in the sets of plans that was provided with the <br /> permit application. But, to clarify any confusion as to what ;is going to be installed. A synopsis of all the fueling <br /> equipment is listed below for your convenience. <br /> The proposed underground storage tanks are as follows: (2) new Modern Welding "Glasleet" Type 1,double <br /> wall steel fiberglass clad, one 12,000 gallon tank will be used for gasoline storage & the other 20,000 gal.tank <br /> will be used for diesel storage. All underground storage tanks will have new polyethylene secondary <br /> containment sumps with spill/overfill boxes. The fiberglass collars supplied on these tanks are compatible with <br /> the Total Containment polyethylene sumps and adapter collars. <br /> The proposed piping at this site will be as follows: The product piping at the facility will be double wall <br /> consisting of Total Containment "Enviroflex H, UL & ULC Listed #PP1501" for gasoline supply and <br /> "Enviroflex H, UL & ULC Listed 9PP2501" for diesel supply. Each of the previously mentioned pressure <br /> supply pipes will be incased with "Enviroflex Secondary Piping,UL Listed #SP4500". All vapor recovery and <br /> tank vent piping and fittings will be single wall fiberglass Amron "Dualoy #3000/L". <br /> A State Approved Veeder-Root TLS-350 monitoring system (#847090-022) with piping sump sensors <br /> (#794390-208), interstitial sensors (#794390-420), dispenser containment box sensors (#794390-208), tank level <br /> gauging(#847390-109 &#847390-110), and positive fueling shutdown module (#847490-200) will be installed. <br /> The project will be equipped with dispenser containment box leak detectors (the same used for piping sumps). <br /> All sensors are to meet the stats standards #LG 113-10. <br /> The general contractor, Maness Environmental Services, Inc., will be handling their portion of the <br /> requirements, should you need information from them please contact Joe Partida at (310) 595-4555.I'm sure <br /> DRAFTING,DESIGN,PROJECT MANAGEMENT AND DEVELOPMENT,PLANNING,PERMITS,COST ESTIMATING,AND MUCH MORE <br /> EXPERIENCE SERVICE QUALITY SATISFACTION <br />